1. Introduction
This manual provides detailed instructions for the KETOTEK Wattmeter Plug Energy Meter (Model: KTEM01BLFR). This device is designed to accurately monitor the power consumption of your household appliances, helping you understand and manage your energy usage. It features 11 monitoring modes, a clear backlit LCD screen, data memory, and essential protection functions.
Please read this manual thoroughly before using the product to ensure safe and efficient operation.
2. Safety Information
- Do not exceed the maximum load capacity of 3680W. Overloading can cause damage to the device and connected appliances, and poses a fire hazard.
- Ensure the device is properly plugged into a grounded outlet.
- Do not disassemble or attempt to repair the device. Contact qualified personnel for service.
- Keep the device away from water, moisture, and extreme temperatures.
- This device is intended for indoor use only.
- Keep out of reach of children.
3. Product Overview
3.1 Components
The KETOTEK Wattmeter consists of a main unit with an integrated FR plug, a display screen, and control buttons.

Figure 1: KETOTEK Wattmeter Plug Energy Meter
- LCD Display: Shows various measurement parameters.
- MODE Button: Cycles through display modes and selects settings.
- SET Button: Enters and saves settings.
- UP Button: Increases values during settings adjustment.
- DOWN Button: Decreases values during settings adjustment, also controls backlight.
- FR Plug: For connecting to a standard French wall outlet.
- FR Socket: For connecting an appliance.
3.2 Display Modes (11 Modes)
The wattmeter offers 11 different display modes to monitor various electrical parameters:

Figure 2: Overview of 11 Monitoring Modes
- Mode 1: Power (W) - Displays current power consumption in Watts.
- Mode 2: Accumulated Electricity Consumption (kWh) - Shows total energy consumed in kilowatt-hours.
- Mode 3: CO2 Emission (kgCO2) - Estimates CO2 emissions based on energy consumption.
- Mode 4: Voltage (V) & Frequency (Hz) - Displays current voltage and frequency.
- Mode 5: Current (A) & Power Factor - Shows current in Amperes and the power factor.
- Mode 6: Minimum Power (W) - Records the lowest power consumption detected.
- Mode 7: Maximum Power (W) - Records the highest power consumption detected.
- Mode 8: Overload Alarm (W) - Displays the set overload threshold.
- Mode 9: Cost Alarm (Currency) - Displays the set cost alarm threshold.
- Mode 10: kWh Alarm (kWh) - Displays the set kWh alarm threshold.
- Mode 11: Electricity Cost (Currency) - Calculates and displays the total electricity cost.
4. Setup
- Initial Connection: Plug the KETOTEK Wattmeter into a standard FR wall outlet.
- Connect Appliance: Plug the appliance you wish to monitor into the socket on the wattmeter.
- Power On: The device will automatically power on and display the default monitoring mode.

Figure 3: FR Plug Type
5. Operation
The following instructions detail how to use the various functions of your KETOTEK Wattmeter.
5.1 Changing Display Modes
Press the MODE button repeatedly to cycle through the 11 available display modes (refer to Section 3.2 for a list of modes).
Video 1: KETOTEK Wattmeter Video Guide. This video demonstrates how to navigate through the 11 display modes, set electricity costs, configure overload, kWh, and cost alarms, utilize data memory, clear data, perform a full reset, and adjust backlight settings.
5.2 Setting Electricity Cost
To accurately calculate electricity costs, you need to set your local electricity price per kWh:
- Press and hold the SET button for 3 seconds to enter the electricity price setting mode.
- Press the MODE button to select the digit you wish to adjust.
- Use the UP or DOWN buttons to change the value of the selected digit.
- Once the desired price is set, press the SET button to save the settings.

Figure 4: Setting Electricity Cost
5.3 Setting Overload Alarm
The device features an overload protection alarm. The default overload power is 3680W, adjustable from 0 to 3680W.
- Press and hold the MODE and SET buttons simultaneously for 3 seconds to enter the overload alarm setting mode.
- Press the MODE button to select the digit you wish to adjust.
- Use the UP or DOWN buttons to change the value.
- Press the SET button to save the overload setting.

Figure 5: Overload Alarm Setting
5.4 Setting kWh Alarm
You can set an alarm for accumulated kWh consumption:
- Press and hold the MODE and DOWN buttons simultaneously for 3 seconds to enter the kWh alarm setting mode.
- Press the MODE button to select the digit you wish to adjust.
- Use the UP or DOWN buttons to change the value.
- Press the SET button to save the kWh alarm setting.
5.5 Setting Cost Alarm
You can set an alarm for the total electricity cost:
- Press and hold the MODE and UP buttons simultaneously for 3 seconds to enter the cost alarm setting mode.
- Press the MODE button to select the digit you wish to adjust.
- Use the UP or DOWN buttons to change the value.
- Press the SET button to save the cost alarm setting.
5.6 Data Memory Function
The KETOTEK Wattmeter is equipped with a high-precision chip that automatically saves data in case of a power outage. Data is stored permanently, allowing you to unplug the device and view readings without losing information.

Figure 6: Unplug to Read Data
5.7 Clearing Data
To clear accumulated data (cost, kWh, CO2, min/max power, total time) without resetting other settings:
- Press and hold the DOWN button for 5 seconds until the screen flashes.
- Then, press the MODE button to clear all accumulated data.
5.8 Reset Function
To perform a full factory reset, which clears all data and restores default settings:
- Locate the small reset button (usually a pinhole) on the device.
- Use a thin, pointed object (like a paperclip) to press and hold the reset button until the display clears or resets.

Figure 7: Reset Button Location
5.9 Backlight and Time Settings
The device features a backlit LCD screen for easy reading in dark areas. The default backlight duration is 10 minutes.
- Turn Backlight On/Off: Press the DOWN button to toggle the backlight on or off. Pressing any button will activate the backlight if it's off.
- Adjust Backlight Duration: Press and hold the UP and DOWN buttons simultaneously to enter the backlight duration setting mode. Use UP or DOWN to adjust the duration (e.g., 'BL-0' for off, 'BL-1' for 1 minute, 'BL-' for continuous). Press SET to save.

Figure 8: Backlight On vs. Off
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank or not turning on. | No power to the outlet; device malfunction. | Check if the wall outlet is working. Try plugging another device into the outlet. If the problem persists, the wattmeter may be faulty. |
| Readings seem inaccurate. | Incorrect electricity cost setting; device malfunction. | Verify your electricity cost setting (Section 5.2). Perform a full reset (Section 5.8). If still inaccurate, compare with another known measurement device. |
| Overload alarm triggers frequently. | Connected appliance exceeds set overload limit; overload limit set too low. | Check the power consumption of your appliance. Adjust the overload alarm limit if necessary (Section 5.3), ensuring it does not exceed the device's maximum capacity (3680W). |
| Backlight not working or staying on. | Backlight duration setting; device malfunction. | Check and adjust the backlight duration setting (Section 5.9). |
| Data is lost after unplugging. | Internal battery issue (for data retention); device malfunction. | The device has an internal battery (CR2032) for data retention. If data is consistently lost, the battery may need replacement or there is a device fault. |
7. Specifications
- Model: KTEM01BLFR
- Dimensions (L x W x H): 5.8 x 7.7 x 12 cm
- Weight: 180 grams
- Voltage: 230 Volts AC
- Maximum Load: 3680W
- Power Source: AC
- Battery: 1 x CR2032 (included, Lithium Manganese Dioxide type)
- Display: Backlit LCD
- Monitoring Modes: 11 (Power, kWh, CO2, Voltage, Frequency, Current, Power Factor, Min/Max Power, Overload Alarm, Cost Alarm, kWh Alarm)
- Color: White

Figure 9: Product Dimensions
8. Warranty and Support
KETOTEK is committed to providing high-quality products. For warranty information, technical support, or any questions regarding your KTEM01BLFR Wattmeter, please refer to the contact information provided with your purchase or visit the official KETOTEK website.
Please retain your proof of purchase for warranty claims.





