Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Rx Clear Maxi Force Pump Dual Speed 1.5 HP. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.
The Rx Clear Maxi Force Pump is engineered for maximum performance and energy efficiency in above-ground pool applications. It is designed to circulate, filter, and clean your pool water effectively throughout the season.
Safety Information
Always follow basic safety precautions when installing and operating this electrical equipment. Failure to follow instructions can result in serious injury or death.
- Disconnect power before servicing.
- Ensure proper grounding and bonding.
- Do not operate if the power cord is damaged.
- Keep children away from the pump area.
- Consult a qualified electrician for electrical installation.
Product Overview

Figure 1: Side view of the Rx Clear Maxi Force Pump, showing the motor and pump housing with included fittings.

Figure 2: Top view of the pump, highlighting the clear lid for the strainer basket and the power cord connection.

Figure 3: Front view of the pump, showing the intake port and the strainer basket housing.

Figure 4: Close-up view of the pump's threaded connection ports for plumbing.
Setup and Installation
Location Requirements
- Install the pump as close to the pool as possible to minimize friction loss.
- Ensure the location is well-ventilated and protected from direct sunlight and excessive moisture.
- Provide adequate space around the pump for maintenance and air circulation.
- Mount the pump on a firm, level base to prevent vibration and noise.
Plumbing Connections
The pump features standard threaded ports for connection to your pool's plumbing system. Use appropriate PVC fittings and pipe dope or Teflon tape to ensure watertight seals. The intake (suction) port is typically located at the front of the pump, and the discharge (return) port is on top.
Electrical Connections
This pump operates on 115 Volts and comes with a standard 6-foot, 3-prong power cord. Ensure the electrical supply matches the pump's voltage requirements. Always connect to a Ground Fault Circuit Interrupter (GFCI) protected outlet. Consult local electrical codes and a qualified electrician for permanent wiring installations.
Important: The pump must be properly grounded and bonded to the pool structure and other metallic equipment.
Operating Instructions
Priming the Pump
- Ensure all valves are open to allow water flow to the pump.
- Remove the clear lid from the strainer basket and fill the basket with water until it overflows.
- Replace the lid, ensuring it is securely tightened to prevent air leaks.
- Turn on the pump. It should begin to draw water and expel air from the return lines.
- If the pump does not prime within a few minutes, turn it off, re-check for air leaks, and repeat the priming process.
Dual Speed Operation
The Rx Clear Maxi Force Pump features a 2-speed manual switch motor. This allows you to select between a high-speed setting for maximum circulation and cleaning, and a low-speed setting for energy-efficient daily filtration.
- High Speed: Use for initial pool cleaning, vacuuming, backwashing, or when rapid water turnover is desired.
- Low Speed: Ideal for continuous daily filtration, maintaining water clarity, and reducing energy consumption.
Refer to the switch on the motor for speed selection. Always ensure the pump is off before changing speeds to prevent damage.
Maintenance
Strainer Basket Cleaning
The strainer basket collects debris before it enters the pump impeller. A clogged basket reduces pump efficiency and can lead to damage.
- Turn off the pump and disconnect power.
- Close any necessary valves to prevent water from draining from the pool.
- Unscrew the clear lid of the strainer basket.
- Remove the basket and empty any debris. Rinse thoroughly with water.
- Inspect the O-ring on the lid for cracks or wear. Replace if necessary.
- Reinsert the clean basket, ensuring it seats properly.
- Replace the lid, tightening it securely.
- Re-prime the pump if necessary before restarting.
Winterization
Before freezing temperatures arrive, it is crucial to properly winterize your pump to prevent damage.
- Turn off the pump and disconnect power.
- Drain all water from the pump by removing the drain plugs (typically located at the bottom of the pump housing).
- Store the pump in a dry, protected area where it will not freeze.
- Ensure all plumbing lines connected to the pump are also drained or winterized according to pool closing procedures.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump not priming | Low water level, air leak in suction line, clogged strainer basket, closed valve. | Check pool water level, inspect all connections for leaks, clean strainer basket, ensure all valves are open. Re-prime pump. |
| No water flow / Low flow | Clogged strainer basket, clogged impeller, air leak, filter dirty, closed valve. | Clean strainer basket, check impeller for debris, inspect for air leaks, clean or backwash filter, open all valves. |
| Pump making loud noise | Air leak in suction, cavitation (not enough water), worn bearings, debris in impeller. | Check for air leaks, ensure adequate water supply, contact qualified service technician for bearing issues, clear impeller. |
| Pump not turning on | No power, tripped GFCI, faulty motor. | Check power supply, reset GFCI, contact qualified service technician if motor is faulty. |
Specifications
| Feature | Detail |
|---|---|
| Model Number | MX215DNSBS |
| Style | Dual Speed 1.5 HP |
| Voltage | 115 Volts |
| Current Amps | 10/3.6 Amps |
| Maximum Flow Rate | 83 Gallons Per Minute (GPM) |
| Power Source | Corded Electric |
| Item Weight | 25.85 Pounds |
| Included Components | Pool Pump, Standard 6 foot 3 Prong Power Cord |
| UPC | 840304201587 |
Warranty and Support
Specific warranty details for the Rx Clear Maxi Force Pump Dual Speed 1.5 HP are not provided within this manual. Please refer to the product packaging or the manufacturer's official website for comprehensive warranty information.
For technical support, replacement parts, or further assistance, please contact Rx Clear customer service. Contact information can typically be found on the product packaging or the official Rx Clear website.
You can visit the official Rx Clear Store for more information: Rx Clear Store