This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Regent 100L Vertical Electric Water Heater. Please read these instructions carefully before installation and use, and keep them for future reference.

The Regent 100L vertical electric water heater is designed for domestic hot water supply, suitable for households of approximately 4 people. Its compact dimensions (47 x 45 x 91 cm) and modern white finish allow for vertical installation in various spaces, including bathrooms.

Regent 100L Vertical Electric Water Heater front view

Image: Front view of the Regent 100L Vertical Electric Water Heater, showing its white cylindrical design and temperature control dial.

2. Safety Information

Always adhere to local regulations and safety standards during installation and operation. Incorrect installation or use can lead to property damage, injury, or death.

  • Ensure the main power supply is disconnected before any installation, maintenance, or repair work.
  • Installation must be performed by a qualified professional.
  • Do not operate the water heater if it is damaged or malfunctioning.
  • Keep flammable materials away from the water heater.
  • The water heater must be properly grounded.
  • Do not block the pressure relief valve.

3. Setup & Installation

The Regent 100L water heater is designed for vertical installation. Follow these steps carefully:

  1. Preparation: Before positioning the water heater, ensure the main water supply valve to the residence is closed. Identify the installation location, allowing approximately 50 cm of service area for maintenance and hose connections.
  2. Marking: Use a template (if provided in the packaging) or measure and mark the drilling points for the mounting brackets on the wall. Ensure the marks are level for a straight installation.
  3. Drilling: Drill holes at the marked points.
  4. Mounting: Insert wall plugs (not included) into the drilled holes and secure the mounting screws (not included) to fix the hanging brackets.
  5. Positioning: Carefully lift and hang the water heater onto the secured brackets.
  6. Water Connections: Once the water heater is hung, connect the safety valve to the cold water inlet pipe. Then, connect the dielectric sleeves (included) to both the inlet and outlet pipes to prevent corrosion. Ensure all connections are tight and use PTFE tape (not included) to guarantee no leaks.
  7. Filling: Open the hot and cold water taps in your home to allow air to escape and the water heater to fill completely. Once water flows steadily from the hot water tap, the tank is full.
  8. Electrical Connection: Once the water heater is filled with water, connect it to the electrical supply.
Installation steps for Regent 100L Water Heater

Image: Diagram illustrating the step-by-step installation process for the water heater, including marking, drilling, mounting, and connecting water lines.

Included and Not Included Components

The following components are included with your water heater:

  • ✔ Safety Valve
  • ✔ 2 Dielectric Sleeves

The following components are NOT included and must be purchased separately for installation:

  • ✖ Flexible Hoses
  • ✖ Level Tool
  • ✖ Wall Plugs and Screws
  • ✖ PTFE Tape (Teflon)
  • ✖ Wrench for tightening screws
Diagram of included and not included parts for water heater installation

Image: Visual representation of components included with the water heater (safety valve, dielectric sleeves) and those not included (flexible hoses, level, wall plugs/screws, PTFE tape, wrench).

4. Operating Instructions

Your Regent 100L water heater is designed for user-friendly operation.

Temperature Adjustment

The electric water heater's temperature can be manually adjusted using the regulator located at the bottom of the unit. Rotate the dial to set your desired temperature. The thermometer, located on the upper front part of the unit, indicates the current water temperature.

Indicator Light

A red indicator light illuminates when the water heater is actively heating water, providing a visual cue of its operational status.

Water Pressure Control

The water pressure inside the tank can be manually controlled via the cam valve. Refer to the installation section for proper setup of this component.

5. Maintenance

Regular maintenance ensures the longevity and efficiency of your water heater.

  • Anode Inspection: The large magnesium anode is a consumable protective part that reacts with oxygen in the water, preventing corrosion of the tank. It should be inspected and replaced periodically by a qualified technician, typically every 1-2 years, depending on water quality.
  • Dielectric Sleeves: These sleeves prevent corrosion between copper pipes and the steel tank. Inspect them during anode replacement for any signs of wear or damage.
  • Pressure Relief Valve: Test the pressure relief valve annually to ensure it is not blocked and functions correctly. Follow the manufacturer's instructions for testing.
  • Descaling: In areas with hard water, scale buildup can reduce efficiency. Periodic descaling by a professional may be necessary. The titanium-enameled tank helps protect against corrosion and limescale.
  • Cleaning: Keep the exterior of the water heater clean with a damp cloth. Do not use abrasive cleaners.

6. Troubleshooting

Before contacting customer support, review these common issues and solutions:

ProblemPossible CauseSolution
No hot water
  • No power supply
  • Thermostat set too low
  • Heating element failure
  • Check circuit breaker/fuse.
  • Adjust thermostat to a higher setting.
  • Contact a qualified technician for inspection and replacement.
Water not hot enough
  • Thermostat set too low
  • Excessive hot water usage
  • Scale buildup
  • Increase thermostat setting.
  • Allow more time for reheating.
  • Schedule professional descaling.
Water leaks
  • Loose connections
  • Faulty pressure relief valve
  • Tank corrosion
  • Tighten connections (ensure power is off).
  • Contact a qualified technician for inspection/replacement.
  • Contact a qualified technician.
Red indicator light not on when heating
  • No power
  • Light malfunction
  • Check power supply.
  • If water heats normally, the light may need service.

For issues not listed or if solutions do not resolve the problem, please contact customer support.

7. Specifications

Detailed technical specifications for the Regent 100L Vertical Electric Water Heater:

BrandRegent (Manufactured by Ariston)
Model Number3201654
Capacity100 Liters
Power SourceElectric
Voltage230 Volts (AC)
Product Dimensions (L x H)47 cm x 91 cm
Depth47 cm
Heating Time3 hours 40 minutes
Resistance TypeShielded Resistance
Installation TypeVertical (Floor/Wall Mounted)
Energy Efficiency ClassC
MaterialTitanium Alloy Steel (Enameled Tank)
ColorWhite
Regent 100L Water Heater dimensions diagram

Image: Technical diagram showing the dimensions (a, e, f, h, l, q) of the 100L water heater in millimeters.

Regent 100L Water Heater with Energy Efficiency Label C

Image: Front view of the Regent 100L Water Heater displaying its energy efficiency class C label.

8. Warranty & Support

Your Regent 100L Vertical Electric Water Heater comes with a comprehensive warranty:

  • Total Warranty: 3 years
  • Tank Warranty: 5 years

This warranty covers manufacturing defects under normal use and service. Please retain your proof of purchase for warranty claims.

Customer Support

For technical assistance, warranty claims, or service requests, please contact Regent customer support. Refer to the contact information provided with your product packaging or visit the official Regent website.

You can also visit the Ariston Brand Store on Amazon for more information, as Ariston is the manufacturer.

© 2023 Regent. All rights reserved. Information in this manual is subject to change without notice.

Related Documents - 3201654

Preview Regent Uhren Bedienungsanleitung: Anleitung für Uhren mit verschraubter Krone
Umfassende Bedienungsanleitung für Regent Uhren mit verschraubter Krone. Erfahren Sie, wie Sie die Uhrzeit und das Datum korrekt einstellen und die Wasserdichtigkeit erhalten.
Preview How to Fix Rust on Regent Cast Iron Cookware
Learn how to effectively remove rust from Regent cast iron products like skillets and pans, and re-season them for continued use. This guide provides step-by-step instructions and necessary materials.
Preview Regent DVD D-225 User Manual
Comprehensive user manual for the Regent DVD D-225, covering safety, operation, connections, troubleshooting, and technical specifications.
Preview Regent Stovetop Coffee Maker Instructions
Step-by-step guide on how to make coffee using a Regent Stovetop Coffee Maker, also known as a Moka pot. Includes what you need and detailed brewing instructions.
Preview How to Make Coffee with a Regent Coffee Plunger/French Press
Step-by-step instructions for brewing delicious coffee using a Regent Coffee Plunger/French press, including what you need and detailed brewing steps.
Preview Notice d'Utilisation et d'Installation : Atlantic Calypso Connecté Chauffe-Eau Thermodynamique
Guide complet pour l'installation, l'utilisation et la maintenance du chauffe-eau thermodynamique Atlantic Calypso Connecté (modèles 100L et 150L).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.