1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of the Solarhome InteliLite NT AMF25 AMF-25 Control Panel. This control panel is designed for compatibility with ComAp Gen-Set systems, offering reliable monitoring and control functionalities. Please read this manual thoroughly before using the device to ensure safe and efficient operation.
2. Product Overview
The AMF25 AMF-25 is a robust control panel featuring a clear display and intuitive button layout for managing generator sets. It integrates various inputs and outputs for comprehensive system control.

Figure 2.1: Front panel of the Genset Controller AMF-25. This view shows the LCD display, navigation buttons (Mode, Start, Stop, Horn reset, Fault reset, Page, Enter), and status indicators.

Figure 2.2: Angled rear view of the AMF-25 controller. This perspective highlights the various green plug-in terminal blocks for electrical connections, including inputs for generator current, generator voltage, mains voltage, binary inputs, analog inputs, RPM, and binary outputs. The label with model information is also visible.

Figure 2.3: Top-down view of the rear of the AMF-25 controller, providing a clear look at the connection labels and the product information sticker. The sticker indicates "Genset Controller AMF-25" and provides instructions for mounting ("For Use on a Flat Surface of a Type 1 Enclosure"), maximum ambient temperature ("Max.ambient temperature 70°C"), and wire type ("Use Copper Conductors Only"). It also specifies power requirements (8-36 VDC, MAX 0.4A).

Figure 2.4: Straight rear view of the AMF-25 controller, showing the arrangement of the plug-in terminal blocks. This view emphasizes the compact design and the accessibility of all connection points for installation.
3. Setup and Installation
The AMF25 AMF-25 control panel is designed for panel mounting. Ensure all power is disconnected before beginning installation.
- Mounting: Install the control panel on a flat surface within a Type 1 enclosure. The panel dimensions are approximately 8 x 8 x 5 inches.
- Electrical Connections:
- Connect the power supply (8-36 VDC, MAX 0.4A) to the designated terminals.
- Utilize the plug-in connector type terminals for all inputs and outputs.
- Ensure all wiring uses copper conductors and adheres to local electrical codes. Refer to installation instructions for specific torque values for terminal screws.
- Connect generator current (0-5A), generator voltage (3x277/480VAC), and mains voltage (3x277/480VAC) to their respective terminals.
- Connect binary inputs, analog inputs, RPM signals, and binary outputs as required by your Gen-Set system configuration.
- Environmental Considerations: Ensure the operating environment remains within specified temperature and humidity ranges to prevent damage to internal components.
4. Operating Instructions
The AMF25 AMF-25 features an intuitive interface for controlling and monitoring your Gen-Set.
- Power On: Once properly connected, the unit will power on and display the initial screen.
- Navigation: Use the Page buttons (up/down arrows) to scroll through different display screens and parameters.
- Mode Selection: The Mode buttons allow selection between different operating modes (e.g., Manual, Auto, Test). Refer to the Gen-Set specific documentation for detailed mode functionalities.
- Start/Stop: Use the Start button to initiate generator operation and the Stop button to shut down the generator.
- Alarm Management:
- The Horn reset button silences audible alarms.
- The Fault reset button clears fault indications after the underlying issue has been resolved.
- Parameter Adjustment: Use the Enter button to confirm selections or enter sub-menus for parameter adjustments.
For detailed operational sequences and specific parameter settings, consult the comprehensive documentation provided with your ComAp Gen-Set system.
5. Maintenance
Regular maintenance ensures the longevity and reliable performance of your AMF25 AMF-25 control panel.
- Cleaning: Periodically clean the front panel with a soft, dry cloth. Avoid abrasive cleaners or solvents that could damage the display or buttons.
- Inspection: Regularly inspect all wiring connections for tightness and signs of wear or corrosion. Ensure the panel is securely mounted.
- Environmental Check: Verify that the operating environment remains within specified temperature and humidity ranges to prevent damage to internal components.
- Software Updates: If applicable, check with Solarhome or ComAp for any available firmware updates for the control panel.
6. Troubleshooting
This section provides basic troubleshooting steps for common issues. For complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Panel does not power on. | No power supply; incorrect wiring; blown fuse. | Check power connections; verify wiring according to diagram; inspect and replace fuses if necessary. |
| Display is blank or unreadable. | Power issue; display fault; extreme temperature. | Ensure stable power; allow unit to return to normal operating temperature; if problem persists, contact support. |
| Buttons are unresponsive. | Software freeze; physical damage. | Attempt a power cycle (turn off and on); inspect buttons for physical damage. |
| Incorrect readings from sensors. | Sensor malfunction; wiring issue; incorrect calibration. | Check sensor connections; verify sensor type and compatibility; consult Gen-Set manual for calibration procedures. |
7. Specifications
| Attribute | Detail |
|---|---|
| Part Name | Control Panel |
| Part Number / Model | AMF25 AMF-25 |
| Compatibility | ComAp Gen-Set |
| Product Dimensions (L x W x H) | 8 x 8 x 5 inches |
| Manufacturer | Solarhome |
| Country of Origin | China |
| Operation Mode | ON-ON-OFF |
| Current Rating | 25 Amps |
| Operating Voltage | 24 Volts (DC input range 8-36 VDC) |
| Contact Type | Normally Open |
| Connector Type | Plug In |
| Terminal Type | Through Hole |
| Circuit Type | 4-way |
| Contact Material | Alloy Steel |
| Included Components | 1x 6D102 Monitor Display Panel (AMF25 AMF-25 Control Panel) |
8. Warranty Information
Specific warranty terms for the Solarhome InteliLite NT AMF25 AMF-25 Control Panel are provided by the manufacturer or the point of purchase. Please retain your proof of purchase for warranty claims. For detailed warranty coverage, duration, and conditions, refer to the documentation included with your product or contact Solarhome directly.
9. Technical Support
For technical assistance, installation queries, or troubleshooting beyond the scope of this manual, please contact Solarhome customer support or your authorized dealer. When contacting support, please have your product model number (AMF25 AMF-25) and purchase details ready.
Visit the Solarhome Store on Amazon for more information and contact options.