ALPHAGOMED U80BH
ALPHAGOMED U80BH Automatic Upper Arm Blood Pressure Monitor User Manual
Model: U80BH
Introduction
The ALPHAGOMED U80BH Automatic Upper Arm Blood Pressure Monitor is designed for accurate and convenient blood pressure measurement at home. Featuring a large backlit LCD display, oversized operation buttons, and advanced AI algorithms, this device provides reliable readings based on extensive clinical data. It includes two different cuff sizes to accommodate a wide range of arm circumferences, ensuring comfortable and precise measurements for various users.

Image: The ALPHAGOMED U80BH Blood Pressure Monitor with its large display and two included cuffs.
Package Contents
Please verify that all items listed below are included in your package:
- 1 x ALPHAGOMED Blood Pressure Monitor (Main Unit)
- 1 x Standard Size Cuff (9"-17" / 22-43 cm)
- 1 x Extra Large Cuff (13"-21" / 33-53 cm)
- 1 x Nylon Carry Bag
- 1 x Type-C USB Cable
- 4 x AAA Batteries
- 1 x User Manual (this document)

Image: All components included in the ALPHAGOMED Blood Pressure Monitor package.
Setup
1. Powering the Device
The ALPHAGOMED Blood Pressure Monitor offers two power options:
- AAA Batteries: Open the battery compartment on the bottom of the device and insert the 4 included AAA batteries, ensuring correct polarity (+/-).
- USB-C Cable: Connect the provided Type-C USB cable to the port on the side of the monitor and plug the other end into a compatible USB power source (e.g., wall adapter, computer USB port).
You can use either power source. If using batteries, ensure they are fresh for optimal performance. The device can be powered by the USB-C cable even without batteries installed.

Image: The two power options for the monitor: AAA batteries and USB-C cable connection.
2. Attaching the Cuff
The monitor comes with two cuff sizes: a standard M/L cuff (9"-17") and an extra-large (XL) cuff (13"-21"). Choose the cuff that best fits your upper arm circumference to ensure accurate readings.
- Select the Correct Cuff: Measure your upper arm circumference and select either the M/L cuff (for arm sizes 9-17 inches) or the XL cuff (for arm sizes 13-21 inches).
- Connect the Cuff: Insert the air tube connector from the chosen cuff firmly into the air jack on the side of the main monitor unit.
- Position the Cuff:
- Place the cuff on your bare upper arm, approximately 1-2 cm (0.4-0.8 inches) above the elbow joint.
- Ensure the air tube runs down the center of your arm, aligned with your middle finger.
- The bottom edge of the cuff should be above the bend of your elbow.
- Wrap the cuff snugly around your arm, but not too tightly. You should be able to insert two fingers between the cuff and your arm.

Image: Illustration of the two cuff sizes and proper cuff placement on the upper arm.
Operation
1. Taking a Measurement
For accurate readings, ensure you are relaxed, seated comfortably with your feet flat on the floor, and your arm supported at heart level. Avoid talking or moving during the measurement.
- Prepare for Measurement: Sit quietly for at least 5 minutes before taking a reading. Avoid caffeine, alcohol, and smoking for 30 minutes prior.
- Select User (Optional): The device supports 2 user modes. Press the MEM button to switch between User 1 and User 2 if you wish to store readings separately.
- Start Measurement: Press the large START/STOP button. The cuff will automatically inflate, and the measurement will begin. Remain still and silent.
- View Results: Once the measurement is complete, the cuff will deflate, and your Systolic, Diastolic, and Pulse readings will be displayed on the large backlit LCD screen. The reading will automatically be saved to the selected user's memory.
2. Understanding Readings with 3-Color Indicator
The ALPHAGOMED monitor features a 3-color indicator on the upper right corner of the display, based on WHO (World Health Organization) guidelines, to help you quickly interpret your blood pressure status:
- Green Light: Indicates Normal Blood Pressure.
- Orange Light: Indicates Mild Hypotension (Pre-hypertension) or slightly elevated pressure.
- Red Light: Indicates High Blood Pressure (Hypertension).
Always consult your healthcare professional for interpretation of your blood pressure readings and for any medical advice.

Image: The 3-color indicator on the monitor display, showing normal, mild hypotension, and high blood pressure ranges.
3. User Memory Mode
The monitor can store up to 99 sets of readings for each of two users (User 1 and User 2), allowing you to track your blood pressure trends over time.
- Switch Users: Before taking a measurement, press the SET button to toggle between User 1 and User 2. The selected user icon will be displayed.
- View Memory: Press the MEM button to review past readings for the currently selected user. Each press will cycle through the stored measurements from most recent to oldest.
- Clear Memory: Refer to the detailed instructions in the printed user manual for steps on how to clear stored memory, if desired.

Image: The monitor displaying readings for two different user profiles.
Maintenance
Cleaning
- Wipe the monitor unit and cuff with a soft, dry cloth.
- If necessary, use a cloth lightly dampened with water or a mild detergent. Do not use abrasive cleaners or immerse the device in water.
- Ensure the device is completely dry before storage or next use.
Storage
- Store the monitor and cuff in the provided nylon carry bag to protect them from dust and damage.
- Keep the device in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity.
- If the device will not be used for an extended period, remove the batteries to prevent leakage.
Troubleshooting
If you encounter issues with your blood pressure monitor, please refer to the following common solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Low or dead batteries; incorrect battery polarity; USB-C cable not connected properly. | Replace batteries with new ones, ensuring correct polarity. Check USB-C cable connection. |
| Cuff does not inflate or inflates improperly. | Air tube not securely connected; cuff not properly wrapped; air leakage. | Ensure air tube is firmly inserted. Re-wrap cuff snugly. Check cuff for any damage or holes. |
| Inaccurate or inconsistent readings. | Improper cuff placement; movement or talking during measurement; incorrect body posture; recent physical activity, caffeine, or smoking. | Review "Attaching the Cuff" and "Taking a Measurement" sections. Ensure proper preparation and technique. Take multiple readings and average them. Consult a healthcare professional if discrepancies persist. |
| Error message on display. | Specific error code (e.g., E-1, E-2). | Refer to the comprehensive error code list in the full printed user manual for specific meanings and solutions. Generally, re-apply cuff and re-measure. |
If the problem persists after trying these solutions, please contact customer support.
Specifications
| Model Number | U80BH |
| Product Dimensions | 1.2"L x 1"W x 1"Th (approximate main unit) |
| Item Weight | 1 Pound (approximate, main unit) |
| Cuff Sizes Included | Standard M/L (9"-17"), Extra Large (13"-21") |
| Power Source | 4 x AAA Batteries or Type-C USB Cable |
| Display Type | Large Backlit LCD |
| Memory Capacity | 2 Users, 99 sets of readings per user |
| Included Components | Monitor, Standard Cuff, XL Cuff, Nylon Carry Bag, Type-C Cable, 4 AAA Batteries, User Manual |
Important Safety Information
- This device is intended for home use to measure blood pressure and pulse rate. It is not intended for diagnosis or treatment of any medical condition.
- Always consult your physician for interpretation of blood pressure readings. Self-diagnosis and treatment based on measurement results can be dangerous.
- Do not use this device on infants, children, or individuals who cannot express their consent.
- Keep the device and its components out of reach of small children and pets.
- Do not use the device in a moving vehicle or on an airplane.
- Avoid taking measurements immediately after bathing, exercising, or consuming alcohol/caffeine.
- If you experience discomfort during inflation, press the START/STOP button to immediately stop the measurement and deflate the cuff.
Support
For any questions, concerns, or technical assistance regarding your ALPHAGOMED Blood Pressure Monitor, please contact the manufacturer's customer support. Refer to the contact information provided in the physical user manual included with your product or visit the official ALPHAGOMED website for support details.
Your satisfaction is important to us. We are here to help.
Ask a question about this manual