Izoxis 19923

Izoxis Digital Timer Plug Model 19923

Instruction Manual

1. Introduction

The Izoxis Digital Timer Plug Model 19923 is designed to provide automated control over electrical appliances in your home or office. This device allows you to set precise on/off times for connected equipment, helping to manage energy consumption and enhance home security. Featuring an easy-to-read display and intuitive controls, it supports 230V appliances such as lighting, heating, or other electronics. By automating power cycles, you can prevent unnecessary energy use and create the impression of occupancy when away.

2. Safety Information

  • Do not exceed the maximum load of 3680W or 16A.
  • This device is for indoor use only. Do not expose to moisture or extreme temperatures.
  • Ensure the timer is securely plugged into a grounded wall socket.
  • Do not disassemble or attempt to repair the device. Contact qualified personnel for service.
  • Keep out of reach of children.
  • Unplug the timer from the wall socket before cleaning.

3. Product Overview

Familiarize yourself with the components and controls of your Izoxis Digital Timer Plug.

Front view of Izoxis Digital Timer Plug with dimensions

Figure 3.1: Front view of the Izoxis Digital Timer Plug, showing the display, control buttons, and socket. Dimensions are indicated as 11.2 cm height, 7.5 cm width, and 5.5 cm depth.

Close-up of Izoxis Digital Timer Plug display and buttons

Figure 3.2: Close-up view of the timer's digital display and control buttons. The buttons include SET, CLOCK, PROG, UP, OK, RESET, and CLEAR.

Controls:

  • SET: Enters setting mode for time and programs.
  • CLOCK: Used to set the current time and day.
  • PROG: Used to set ON/OFF programs.
  • UP: Adjusts values upwards during setting.
  • OK: Confirms selections.
  • RESET: Clears all settings and returns to factory defaults.
  • CLEAR: Deletes current program settings.

4. Setup

Follow these steps for initial setup of your timer plug.

  1. Initial Charge: Plug the timer into a live wall socket for at least 30 minutes to charge the internal battery. This retains settings during power outages.
  2. Reset Device: Press the RESET button using a small pointed object (e.g., a pen tip) to clear all previous settings. The display will show 00:00.
  3. Set Current Time:
    • Press the CLOCK button. The hour digit will flash.
    • Use the UP button to adjust the hour.
    • Press OK to confirm the hour. The minute digit will flash.
    • Use the UP button to adjust the minute.
    • Press OK to confirm the minute. The day of the week will flash.
    • Use the UP button to select the current day (MO, TU, WE, TH, FR, SA, SU).
    • Press OK to save the current time and day.
  4. 12/24 Hour Mode: To switch between 12-hour and 24-hour display, press the CLOCK button and then the UP button simultaneously.
  5. Summer Time: To activate or deactivate summer time, press the CLOCK button and then the SET button simultaneously. An 'S' will appear on the display when summer time is active.
Izoxis Digital Timer Plug plugged into a wall socket

Figure 4.1: The Izoxis Digital Timer Plug correctly inserted into a standard wall socket, ready for use.

5. Operating Instructions

This section details how to program and operate your timer plug.

5.1. Setting Programs (ON/OFF Times)

The timer allows for multiple ON/OFF programs. To set a program:

  1. Press the PROG button. The display will show "1 ON" and the hour digit will flash.
  2. Use the UP button to set the desired ON hour for the first program. Press OK.
  3. Use the UP button to set the desired ON minute. Press OK.
  4. Use the UP button to select the day(s) for this ON program (e.g., MO-FR, SA-SU, or individual days). Press OK.
  5. The display will now show "1 OFF" and the hour digit will flash. Repeat steps 2-4 to set the desired OFF time and day(s) for the first program.
  6. After setting "1 OFF", press PROG again to move to "2 ON" and repeat the process for additional programs.
  7. Once all programs are set, press the CLOCK button to return to the current time display.

5.2. Manual Override Modes

The timer has different operating modes:

  • AUTO: The timer operates according to the programmed ON/OFF times. This is the default and recommended mode.
  • ON: The connected appliance is continuously ON, overriding all programs.
  • OFF: The connected appliance is continuously OFF, overriding all programs.

To cycle through these modes, press the SET button repeatedly until the desired mode (AUTO, ON, or OFF) is displayed.

Izoxis Digital Timer Plug in use with a USB charger plugged in

Figure 5.1: The Izoxis Digital Timer Plug actively controlling a connected USB charger, demonstrating its practical application.

6. Maintenance

To ensure the longevity and proper functioning of your timer plug, follow these maintenance guidelines:

  • Cleaning: Disconnect the timer from the power outlet before cleaning. Wipe the exterior with a soft, dry cloth. Do not use liquid cleaners or abrasive materials.
  • Storage: If storing the timer for an extended period, ensure it is clean and dry. Store in a cool, dry place away from direct sunlight.
  • Battery: The internal battery is designed to retain settings. If the display is blank or settings are lost frequently, ensure the timer is plugged in for sufficient time to charge the battery.

7. Troubleshooting

If you encounter issues with your Izoxis Digital Timer Plug, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Display is blank or not responding.Internal battery is discharged.Plug the timer into a live wall socket for at least 30 minutes to charge the battery.
Programs are not activating.Timer is not in AUTO mode. Incorrect program settings.Ensure the timer is set to AUTO mode. Review and re-enter your program settings carefully.
Connected appliance does not turn ON/OFF.Appliance is faulty. Timer is faulty.Test the appliance by plugging it directly into a wall socket. If the appliance works, the timer may be faulty.
Time or settings are lost after unplugging.Internal battery not fully charged or failing.Ensure the timer is plugged in for a longer duration (e.g., 24 hours) to fully charge the battery. If the problem persists, the battery may need service.

8. Specifications

Model:19923
Brand:Izoxis
Color:White
Voltage:230 V / 50 Hz
Maximum Power:3680 W
Maximum Current:16 A
Operating Temperature:0 to 50 °C
Operating Mode:24 / 12 hours
Summer Time Adjustment:Yes
Dimensions (L x W x H):11.2 x 7.5 x 5.5 cm
Weight:0.143 kg

9. Warranty and Support

Specific warranty information for the Izoxis Digital Timer Plug Model 19923 is not provided in the product details. For warranty claims or technical support, please contact your retailer or the manufacturer directly using the contact information provided at the point of purchase.

Related Documents - 19923

PreviewIzoxis YYK-520 Bluetooth Headset User Manual
User manual for the Izoxis YYK-520 Bluetooth headset, providing instructions on setup, pairing, button functions, troubleshooting, and safety guidelines. Discover the ease of wireless connectivity and enjoy clear audio for calls and music.
PreviewDomus Blaze-Pro-Marine-100 Floodlight F&P - Product Overview and Specifications
Detailed product information for the Domus Blaze-Pro-Marine-100 Floodlight F&P, featuring marine-grade construction, IP66 rating, tri-colour LED technology, and optional sensor compatibility. Ideal for outdoor and coastal environments.