Introduction
The GODOX UMic12 is a high-quality cardioid condenser USB microphone designed for clear audio recording. It features a large diaphragm condenser to capture pristine audio while minimizing background noise, making it suitable for podcasts, vocals, and instruments. This microphone offers plug-and-play functionality with Windows and macOS systems, providing a straightforward recording experience.
What's in the Box
Verify that all the following items are included in your package:
- Godox UMic12 Cardioid Condenser USB Microphone
- Desktop Stand
- USB Type-C to USB Cable

Image: The GODOX UMic12 microphone, its foldable desktop stand, and two USB cables (USB-C to USB-A and USB-C to USB-C) are shown together, illustrating the complete package contents.
Product Features
- Cardioid Polar Pattern: Captures audio from the front while minimizing sound from the sides and rear, ideal for focused recording.
- USB Connectivity: Plug-and-play operation with Windows 7/8/10 and Mac OS (excluding Windows XP).
- Real-time Monitoring: Integrated 3.5mm headphone jack for direct audio monitoring during recording.
- Durable Construction: All-metal build for robustness and stability.
- Foldable Desktop Stand: Included for convenient placement and portability.
- User-friendly Controls: Features a mute button and volume adjustment.
- Wide Frequency Response: 50Hz-20KHz for capturing a broad range of sounds.
- High Signal-to-Noise Ratio: Greater than 70dB for clear audio.
Setup Guide
- Attach the Microphone to the Stand: Securely screw the microphone onto the provided desktop stand. The stand allows for angle adjustment.
- Connect to Computer: Use the provided USB Type-C cable to connect the microphone's USB-C port to an available USB port on your computer (Windows 7/8/10 or Mac OS).
- Driver Installation: The microphone is plug-and-play. Your operating system should automatically detect and install the necessary drivers. No manual driver installation is typically required.
- Select as Input Device: Open your computer's sound settings or your recording software's audio input settings. Select "GODOX UMic12" as your primary audio input device.
- Connect Headphones (Optional): For real-time monitoring, plug your headphones into the 3.5mm headphone jack located on the microphone.

Image: The GODOX UMic12 microphone is shown mounted on its desktop stand, illustrating how it appears when assembled and ready for use.

Image: A close-up of the microphone's base, highlighting the USB-C port for computer connection and the 3.5mm headphone jack for monitoring.
Operating Instructions
Once the microphone is set up, you can begin recording and monitoring your audio.
- Microphone Placement: Position the microphone approximately 6-12 inches (15-30 cm) from the sound source. Due to its cardioid pattern, ensure the front of the microphone (where the GODOX logo is visible) is facing the sound source for optimal capture.
- Mute Function: Press the MUTE button on the microphone to instantly mute or unmute the audio input. An indicator light may show the mute status (refer to specific model's LED behavior).
- Volume Adjustment: Use the volume control buttons (typically '+' and '-') on the microphone to adjust the headphone monitoring volume. This does not affect the input level sent to the computer.
- Real-time Monitoring: The 3.5mm headphone jack provides zero-latency monitoring of your audio. This allows you to hear your voice or instrument as it is being recorded, ensuring proper levels and sound quality.
- Software Settings: Adjust input gain and other audio settings within your recording software (e.g., Audacity, OBS, GarageBand) for optimal recording levels. Avoid peaking (audio distortion) by keeping levels in the green/yellow range.

Image: A direct front view of the GODOX UMic12 microphone, showing the grille and the GODOX logo, indicating the primary pickup direction.

Image: A side view of the GODOX UMic12 microphone, clearly showing the 'MUTE' button and various regulatory markings on its body.

Image: A side view of the GODOX UMic12 microphone, highlighting the '+' and '-' buttons for volume control, positioned near the top of the microphone body.
Maintenance
Proper care will extend the life and performance of your GODOX UMic12 microphone.
- Cleaning: Use a soft, dry cloth to wipe the microphone body. Do not use liquid cleaners or solvents, as they may damage the finish or internal components.
- Storage: When not in use, store the microphone in a clean, dry place, away from dust and extreme temperatures.
- Handling: Avoid dropping the microphone or subjecting it to strong impacts, which can damage the sensitive condenser capsule.
- Cable Care: Do not bend or crimp the USB cable excessively. Store it neatly to prevent damage.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No sound from microphone |
|
|
| Low or distorted audio quality |
|
|
| Headphone monitoring not working |
|
|
Specifications
| Feature | Detail |
|---|---|
| Model | UMic12 |
| Polar Pattern | Unidirectional (Cardioid) |
| Connectivity Technology | USB |
| Connector Type | USB Type-C |
| Frequency Response | 50Hz-20KHz |
| Signal-to-Noise Ratio | 40 dB |
| Audio Sensitivity | 30 Decibels |
| Hardware Platform | PC (Compatible with Windows 7/8/10, Mac OS) |
| Power Source | Corded Electric (USB Powered) |
| Material | Metal |
| Item Weight | Microphone: 13 oz (369g), Stand: 4.93 oz (140g) |
| Product Dimensions (L x W x H) | 9 x 8.7 x 3.2 inches |
| Special Features | Desktop Stand, Volume Control, Mute Function, 3.5mm Headphone Jack |
Warranty Information
GODOX products typically come with a limited manufacturer's warranty. For detailed information regarding the warranty period, coverage, and terms and conditions for your UMic12 microphone, please refer to the warranty card included with your product or visit the official GODOX website.
Support
If you encounter any issues not covered in this manual or require further assistance, please contact GODOX customer support. You can find contact information and additional resources on the official GODOX website: