1. Introduction

This manual provides essential information for the safe and efficient operation of your Gearlux SP184 18 LED 10 Watt RGBW PAR Stage Light. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Safety Information

  • Ensure the power supply voltage matches the specified voltage on the device.
  • Always disconnect the power before cleaning or servicing the unit.
  • Do not operate the device if the power cord is damaged.
  • Avoid direct eye exposure to the light source.
  • This device is for indoor use only. Protect it from moisture and extreme temperatures.
  • Ensure adequate ventilation around the unit to prevent overheating.

3. Product Overview

3.1 Key Features

  • Quad-Color LEDs: Equipped with 18x10-watt RGBW (Red, Green, Blue, White) LEDs for versatile color mixing and high output.
  • Efficient Cooling: Features a quiet cooling fan for effective heat dissipation, contributing to a longer product lifespan.
  • RDM Functionality: Supports RDM (Remote Device Management) via 8 DMX channels for simplified configuration and control.
  • Flexible Mounting: Includes an adjustable metal handle/bracket for easy installation on walls, trusses, or for ground placement.

3.2 Components

Familiarize yourself with the main components of the Gearlux SP184 PAR light:

Front view of the Gearlux SP184 PAR Stage Light

Figure 1: Front view of the Gearlux SP184 PAR Stage Light, showing the 18 RGBW LED lenses.

Rear view of the Gearlux SP184 PAR Stage Light control panel

Figure 2: Rear view of the control panel, featuring DMX In/Out, Power In/Out, digital display, and control buttons.

  • LED Array: 18 individual 10-watt RGBW LEDs on the front panel.
  • Control Panel: Located on the rear, includes a digital display and four control buttons (MENU, UP, DOWN, ENTER).
  • DMX Connections: XLR 3-pin DMX In and DMX Out ports for linking with DMX controllers and other fixtures.
  • Power Connections: Power In and Power Out ports for daisy-chaining power to multiple units. Includes a fuse holder.
  • Mounting Bracket: An adjustable metal bracket for secure positioning.

4. Setup and Installation

4.1 Unpacking

Carefully remove the fixture from its packaging. Inspect the unit for any signs of damage during transit. Retain the packaging for future transport or storage.

4.2 Mounting

The Gearlux SP184 can be mounted in various positions using its adjustable bracket:

  • Floor Mount: Place the unit on a stable, level surface. Adjust the bracket to direct the light as desired.
  • Wall Mount: Securely attach the bracket to a sturdy wall using appropriate hardware (not included). Ensure the mounting surface can support the weight of the fixture.
  • Truss Mount: Attach the bracket to a lighting truss using a suitable clamp (not included). Always use a safety cable when mounting overhead.
Side view of the Gearlux SP184 PAR Stage Light showing the adjustable bracket

Figure 3: Side view illustrating the adjustable mounting bracket and knob for angle adjustment.

4.3 Power Connection

Connect the provided power cable to the "Power In" port on the rear of the unit and then to a suitable power outlet (AC 100-240V, 50/60Hz). Multiple units can be daisy-chained using the "Power Out" port, but ensure the total current draw does not exceed the circuit's capacity.

Close-up of the Power In connection on the Gearlux SP184

Figure 4: Detail of the Power In port with a connected power cable.

4.4 DMX Connection

For DMX control, connect a DMX cable from your DMX controller's output to the "DMX In" port of the first fixture. For multiple fixtures, connect the "DMX Out" of the first fixture to the "DMX In" of the next, and so on. Use a DMX terminator on the last fixture in the chain for optimal signal integrity.

5. Operating Instructions

5.1 Control Panel Navigation

The digital display and four buttons on the rear panel allow you to navigate menus and select operating modes:

  • MENU: Cycles through the main menu options.
  • UP/DOWN: Navigates through sub-menu options or adjusts parameter values.
  • ENTER: Confirms a selection or saves a setting.

5.2 Operating Modes

The Gearlux SP184 typically offers several operating modes:

  • DMX Mode: Allows external control via a DMX controller. Set the DMX address for the fixture. The unit uses 8 DMX channels.
  • Auto Mode: The fixture runs through pre-programmed light shows automatically.
  • Sound Active Mode: The light reacts to sound detected by its built-in microphone.
  • Master/Slave Mode: Link multiple units where one acts as the master (controlling) and others as slaves (following).
  • Static Color Mode: Select and display a single static color (Red, Green, Blue, White, or mixed colors).
Gearlux SP184 PAR light emitting white light

Figure 5: The PAR light displaying a white output, demonstrating its RGBW capabilities.

Gearlux SP184 PAR light emitting pink/magenta light

Figure 6: The PAR light displaying a pink/magenta output, showcasing color mixing.

Gearlux SP184 PAR light emitting green light

Figure 7: The PAR light displaying a green output.

5.3 RDM Function

The RDM (Remote Device Management) function allows for two-way communication between the DMX controller and the fixture. This enables remote setting of DMX addresses, mode changes, and monitoring of fixture status directly from an RDM-compatible DMX controller, simplifying setup and troubleshooting.

6. Maintenance

6.1 Cleaning

To maintain optimal light output and cooling efficiency, regularly clean the fixture's lenses and cooling vents. Use a soft, lint-free cloth and a mild glass cleaner for the lenses. Ensure the unit is powered off and disconnected before cleaning.

6.2 Fuse Replacement

If the unit does not power on, check the fuse located near the power input. Disconnect power, unscrew the fuse holder, and replace the fuse with one of the same type and rating (e.g., T2A 250V). Never use a fuse with a higher rating.

6.3 Storage

When not in use, store the fixture in its original packaging or a suitable case in a dry, dust-free environment.

7. Troubleshooting

ProblemPossible CauseSolution
Fixture does not power on.No power supply; Blown fuse; Damaged power cable.Check power connection; Replace fuse; Inspect/replace power cable.
No DMX control.Incorrect DMX address; Faulty DMX cable; No DMX signal; Missing terminator.Verify DMX address; Check DMX cables; Ensure DMX controller is active; Add DMX terminator.
Light output is dim or inconsistent.Dirty lenses; Overheating; Incorrect mode/settings.Clean lenses; Ensure proper ventilation; Check operating mode and dimmer settings.
Fixture is overheating.Blocked ventilation; Insufficient airflow.Clear all obstructions from vents; Ensure adequate space around the unit.

8. Specifications

FeatureDetail
ModelSP184
BrandGearlux
Light Source18 x 10 Watt RGBW LEDs
Power SourceCorded Electric
Input VoltageAC 100-240V, 50/60Hz
Wattage10 Watts (per LED)
DMX Channels8 Channels
Beam Angle25 Degrees
MaterialMetal (Aluminum)
Finish TypeAluminum, Metal
Mounting TypeWall Mount, Floor Mount
Product Dimensions11.61"L x 6.1"W x 11.81"H
Item Weight7.67 pounds

9. Warranty and Support

For warranty information or technical support, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your proof of purchase for any warranty claims.

Documents - Gearlux – SP184

no relevant documents