GOLDCHAMP GC-EU-38A

GOLDCHAMP GC-EU-38A Voltage and Continuity Tester

Model: GC-EU-38A | Brand: GOLDCHAMP

1. Introduction

The GOLDCHAMP GC-EU-38A is a digital voltage and continuity tester designed for testing AC/DC currents. It features a rotating field test, single-pole voltage test, and continuity test. For operation in low-light conditions, a built-in flashlight illuminates the measurement point. This voltmeter is suitable for use in electrical engineering, industrial applications, maintenance, and photovoltaics. Constructed with high-quality components, it provides accurate readings even after frequent use. Its compact dimensions and low net weight make it portable and easy to carry.

2. Safety Precautions

Read all safety information and operating instructions before using this instrument. Failure to follow these warnings and instructions can result in electric shock, fire, or serious injury.

  • Never take measurements on a circuit where the electrical potential exceeds 690V. If the measured voltage exceeds 690V, all voltage LED indicators will illuminate.
  • Do not attempt to take measurements in the presence of flammable gases, as the instrument may cause sparks that could lead to an explosion.
  • Never use the instrument with wet hands or in the rain.
  • Keep your hands and fingers behind the barriers during measurements.
  • Never unlock or open the battery compartment during measurement.
  • Always verify proper operation on a known live source before taking measurements.
  • Never attempt to take measurements under abnormal conditions, such as a broken casing or exposed metal parts on the instrument or test leads.
  • Do not modify the instrument.
  • Exercise extreme caution when the LED circuit flashes or illuminates.
  • The correct display of LEDs is guaranteed only within a temperature range of -10°C to 55°C (< 85% RH).

3. Product Features

  • Bipolar Voltage Tester: Measures AC/DC voltage (including three-phase AC power), displays three-phase AC power phase, ON/OFF test, continuity, phase rotation test, polarity detection, and self-inspection.
  • Safety Compliance: Features a low battery indicator and over-range voltage indicator. Complies with safety requirements for double insulation, CAT III 690V, CAT IV 600V, and CE standards.
  • Easy to Use: Backlit digital LCD for clear readings. Portable design.
  • Measurement Range: 12-690V AC/DC. Accuracy (23 ± 5°C): (3% + 3) or 5V. Range/Resolution: 7-690V/1V (Auto-range).
  • Integrated Flashlight: For illuminating dark work areas.
  • Data Hold Function: Locks the measured value on the LCD for convenient reading.
  • Automatic Power Off: Saves battery life when not in use.
  • IP64 Protection Class: Protected against splashes and dust.
GOLDCHAMP GC-EU-38A Voltage Tester with key features listed

Figure 3.1: Key features of the GOLDCHAMP GC-EU-38A Voltage Tester, including pen light, auto power off, continuity test, LED indication, threshold voltage, and phase rotation test.

4. Getting Started

4.1 Unpacking

Carefully remove the GOLDCHAMP GC-EU-38A Voltage and Continuity Tester from its packaging. Ensure all components are present:

  • 1 x Voltage Tester with Test Probes
  • 1 x User Manual
  • 2 x 1.5V Batteries (AA type)

4.2 Battery Installation

The tester is powered by two 1.5V batteries (IEC LR03 1.5Vx2). To install or replace batteries:

  1. Ensure the device is turned off and disconnected from any power source.
  2. Locate the battery compartment cover, typically at the bottom or rear of the device.
  3. Use a small coin to open the battery compartment cover.
  4. Insert the two 1.5V batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Securely close the battery compartment cover.
GOLDCHAMP GC-EU-38A Voltage Tester showing battery compartment and dimensions

Figure 4.1: The GOLDCHAMP GC-EU-38A Voltage Tester with its battery compartment open, showing the required 1.5V AA batteries.

4.3 Initial Self-Test

Before each use, it is recommended to perform a self-test on a known live source to ensure the tester is functioning correctly. If the power indicator light blinks or goes out during the self-diagnostic test, the battery may need to be replaced.

Image showing how to replace batteries and use the probe clip on the GOLDCHAMP GC-EU-38A

Figure 4.2: Illustration of battery replacement and the convenient probe clip feature.

5. Operating Instructions

5.1 Overview of Components

Labeled diagram of the GOLDCHAMP GC-EU-38A Voltage Tester components

Figure 5.1: Labeled diagram showing the lamp light, LCD display, SELECT key, battery cover, COM input test lead, protective casing, test lead fixture, and test leads.

Diagram showing button functions and parts of the GOLDCHAMP GC-EU-38A Voltage Tester

Figure 5.2: Detailed view of the probe cover, test leads, battery compartment, LED light, and the main display.

5.2 Voltage Measurement (AC/DC)

The tester automatically detects AC or DC voltage. Connect the test probes to the circuit or component you wish to measure. The voltage will be displayed on the LCD, and corresponding LED indicators will light up.

  • LED Indication Voltage Test:
    Voltage Range: 12-690V AC/DC
    Nominal Voltage (European): 12/24/50/120/230/400/690V
    Tolerance (Threshold Voltage) Light ON at more than:
        - 7 ± 5V (12V LED)
        - 18 ± 5V (24V LED)
        - 37.5 ± 5V (50V LED)
        - 75% ± 5% of nominal voltage (120/230/400/690V)
    Response Time: <0.5s at 100% of each nominal voltage
  • LCD Display Voltage Test:
    Range / Resolution: 7-690V / 1V (Auto-Range)
    Accuracy (23 ± 5°C): (3% + 3) or 5V
    Overrange Indication: All Voltage LEDs light up
    Response Time: <1s at 90% of each voltage

5.3 Continuity Test

To perform a continuity test, select the continuity function (if applicable via the SELECT button). Connect the test probes across the component or circuit. A buzzer will sound, and an LED indicator will light up if continuity is detected.

  • Detection Range: 0-550KΩ (±200K)
  • Test Current: Approximately 1.5uA (3V battery, 0Ω)

5.4 Phase Rotation Test

This function is used for three-phase AC systems.

  • System: Three-phase 4-wire AC system
  • Frequency: 50Hz~60Hz
  • Phase Range: 120 ± 5 degrees

5.5 Flashlight Function

Press and hold the 'PEN' button for 2 seconds to activate the built-in flashlight. This feature is useful for illuminating dark work areas. The flashlight will typically turn off automatically after a short period or by pressing the button again.

Image showing data hold function and flashlight use on the GOLDCHAMP GC-EU-38A

Figure 5.3: The top light can function even at night, and the data hold feature locks the measured value on the LCD.

5.6 Data Hold Function

Once stable data is measured, the instrument will lock the value on the LCD screen, which is convenient for reading. The instrument will automatically turn off after 15 seconds if no further action is taken.

GOLDCHAMP GC-EU-38A Voltage Tester in various usage scenarios

Figure 5.4: The GOLDCHAMP GC-EU-38A in use for AC voltage testing in a wall socket and DC voltage testing in an automotive application.

GOLDCHAMP GC-EU-38A Voltage Tester performing a phase sequence test on a circuit breaker panel

Figure 5.5: Performing a phase sequence test on a three-phase circuit breaker panel.

6. Maintenance

6.1 Cleaning

To clean the instrument, wipe the casing with a damp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the instrument is completely dry before use.

6.2 Battery Replacement

When the low battery indicator appears on the display, or if the power indicator blinks/goes out during self-test, replace the batteries as described in Section 4.2. Always use two new 1.5V AA batteries.

6.3 Storage

If the instrument is not used for a long period, remove the batteries to prevent leakage and damage. Store the tester in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Troubleshooting

  • No Display/Instrument Not Turning On:
    Check battery installation and polarity. Replace batteries if they are low or depleted.
  • Inaccurate Readings:
    Ensure test probes are making good contact. Verify the instrument's functionality on a known live source. Check for any physical damage to the instrument or leads.
  • LEDs Not Lighting Up Correctly:
    Ensure the ambient temperature is within the specified range (-10°C to 55°C). If all voltage LEDs light up, it indicates an over-range condition.
  • Continuity Test Not Working:
    Ensure the continuity function is selected (if applicable). Check for open circuits or high resistance.

8. Technical Specifications

SpecificationValue
ManufacturerGOLDCHAMP
Item Model NumberGC-EU-38A
Product Dimensions (L x W x H)25.1 x 7.7 x 2.8 cm; 250 grams
Batteries2 AA - included
BrandGOLDCHAMP
Power SourceBattery Powered
StyleCompact
ColorBlue
Lower Temperature Rating6 Degrees Celsius
Minimum Operating Voltage12 Volts
Compliant SpecificationsCE, IP64, CAT III 690V, CAT IV 600V
Upper Temperature Rating55 Degrees Celsius
Measurement TypeVoltmeter
GOLDCHAMP GC-EU-38A Voltage Tester showing dustproof rating and detailed specifications

Figure 8.1: Detailed specifications including LED indication voltage test, LCD display voltage test, and dustproof rating (IP61, note: product description states IP64/IP65).

9. Warranty and Support

For any questions or assistance, please contact GOLDCHAMP customer service. We are committed to responding within 24 hours.

Contact Information: Please refer to the product packaging or the official GOLDCHAMP website for the most current customer support contact details.

Related Documents - GC-EU-38A

PreviewGOLDCHAMP DT-4070L 3 1/2 Digital LCR Multimeter Operation Manual
Operation manual for the GOLDCHAMP DT-4070L 3 1/2 digital LCR multimeter. Covers introduction, panel layout, specifications for resistance, capacitance, inductance, and transistor hFE testing, usage instructions, and maintenance.
PreviewGOLDCHAMP Digital Anemometer Instruction Manual - Wind Speed Measurement Guide
Comprehensive user manual for the GOLDCHAMP Digital Anemometer. Learn how to measure wind speed, air volume, and understand its features and specifications for HVAC, drone, and outdoor use.
PreviewKoyo GC 系列触摸屏用户手册
Koyo GC 系列触摸屏用户手册提供了 GC-56LC2、GC-55EM2、GC-53LC3 和 GC-53LM3 型号的操作面板(OIP)的详细信息,包括规格、安装、操作和维护指南。本手册涵盖安全注意事项、通信协议、接口性能和故障排除等内容。
PreviewPotterton Profile Prima Boilers: Installation and Servicing Instructions
Comprehensive installation and servicing guide for Potterton Profile Prima 30e, 40e, 50e, 60e, 80e, and 100e fanned balanced flue gas fired boilers. Includes technical data, site requirements, and maintenance procedures.
PreviewGC Fuji BOND LC: Light-Cured Glass Ionomer Bonding Agent Instructions
Detailed instructions for using GC Fuji BOND LC, a light-cured reinforced glass ionomer bonding agent for dental professionals, covering indications, contraindications, and application techniques for various restorative procedures.
PreviewA&D GC Series Counting Scale Quick Start Guide
This Quick Start Guide provides essential information for the A&D GC Series counting scales, including models GC-3K, GC-6K, GC-15K, and GC-30K. Learn about installation, basic operations, and troubleshooting.