Important Safety Information
Please read and understand all safety instructions before operating this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or serious injury.
- This heater is designed for indoor use only. Do not use outdoors or in wet conditions.
- Ensure the heater is connected to a compatible 240-volt power supply.
- The unit features overheat protection at 104°F (40°C). If the heater overheats, it will automatically shut off. Allow it to cool before restarting.
- Maintain clear space around the heater. Do not block air inlets or outlets.
- Operate on a stable, level surface to prevent tipping.
- This heater operates combustion-free, producing no fuel spills or odors.
- The product is UL approved, indicating compliance with safety standards.
Product Overview
The L.B. White Volt 6 Electric Forced Air Portable Heater is a robust and efficient heating solution designed for various indoor applications. Its compact design and integrated features ensure reliable performance and ease of use.

A white L.B. White Volt 6 electric forced air portable heater with a black handle on top, a black power cord with a 240V plug, and a black fan grille on the side.
Key features include stainless jacketed heating coils, a powder-coated steel housing, and a high-quality sealed motor for quiet, combustion-free operation. An integrated ambient thermostat allows temperature control from 32°F to 100°F (0°C to 38°C).
Specifications
| Feature | Detail |
|---|---|
| Brand | L.B. White |
| Model | Volt 6 |
| Special Feature | Overheat Protection |
| Color | White |
| Form Factor | Cabinet |
| Indoor/Outdoor Usage | Indoor |
| Product Dimensions (D x W x H) | 20" x 12" x 17" |
| Item Weight | 32.9 pounds |
| Mounting Type | Floor Mount |
| Burner Type | Electric |
| Fuel Type | Electric |
| Voltage | 240 Volts |
| Amperage | 25 Amps |
| Min Temperature Setting | 32°F (0°C) |
| Max Temperature Setting | 100°F (38°C) |
| UPC | 681046000324 |
Setup
- Unpack: Carefully remove the heater from its packaging. Retain packaging for future storage or transport.
- Placement: Position the heater on a firm, level surface. Ensure there is adequate clearance (at least 3 feet or 0.9 meters) from walls, furniture, drapes, and other combustible materials. Do not place the heater directly under a power outlet.
- Power Connection: Verify that your power supply matches the heater's requirements (240 Volts, 25 Amps). Plug the heater's power cord directly into a dedicated 240V outlet. Do not use extension cords or power strips.
- Initial Inspection: Before first use, inspect the power cord and plug for any damage. Ensure the air inlet and outlet grilles are clear of obstructions.
Operating Instructions
- Power On: Once properly set up and plugged in, the heater is ready for operation.
- Adjust Thermostat: Locate the ambient thermostat control. Rotate the dial to your desired temperature setting within the range of 32°F to 100°F (0°C to 38°C). The heater will activate to reach and maintain the set temperature.
- Overheat Protection: If the internal temperature exceeds 104°F (40°C), the heater will automatically shut off. To reset, unplug the heater, allow it to cool for at least 30 minutes, then plug it back in. Address any potential causes of overheating, such as blocked air vents.
- Power Off: To turn off the heater, rotate the thermostat dial to its lowest setting or unplug the unit from the power outlet.
Maintenance
Regular maintenance ensures optimal performance and extends the life of your heater. Always unplug the heater before performing any maintenance.
- Cleaning: Use a soft, damp cloth to wipe the exterior surfaces of the heater. Do not use abrasive cleaners or solvents. Ensure no moisture enters the internal components.
- Air Vents: Periodically check and clean the air inlet and outlet grilles to ensure they are free from dust, lint, or other obstructions. A vacuum cleaner with a brush attachment can be used.
- Storage: When not in use, store the heater in a cool, dry place. It is recommended to use the original packaging for protection.
- Cord Care: Do not wrap the power cord tightly around the heater. Avoid kinking or damaging the cord.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Heater does not turn on | No power, tripped circuit breaker, loose connection | Check power outlet, reset circuit breaker, ensure plug is fully inserted. |
| Heater turns on but no heat | Thermostat set too low, overheat protection activated | Increase thermostat setting. If overheat protection activated, unplug, allow to cool, then restart. |
| Heater cycles on and off frequently | Thermostat setting too close to ambient temperature, poor air circulation | Adjust thermostat. Ensure air inlets/outlets are clear and heater is not in an enclosed space. |
| Unusual noise or odor | Dust accumulation, foreign object, internal issue | Unplug immediately. Clean air vents. If problem persists, discontinue use and contact customer support. |
Warranty and Support
For product support, technical assistance, or warranty inquiries, please refer to the contact information provided with your purchase documentation or visit the official L.B. White website.
Extended protection plans are available for this product:
- 3-Year Protection Plan
- 4-Year Protection Plan
These plans offer additional coverage beyond the standard manufacturer's warranty. Please consult the plan details for terms and conditions.