1. Introduction
Thank you for choosing the Tovendor U60AH Wrist Blood Pressure Monitor. This device is designed for easy and accurate measurement of blood pressure and pulse rate at the wrist. It is intended for adult use in a home environment. Please read this manual thoroughly before using the device to ensure correct operation and to obtain the most accurate results.
2. Package Contents
Verify that all items are present in the package:
- 1 x Tovendor Wrist Blood Pressure Monitor (Model U60AH)
- 1 x Storage Case
- 2 x AAA Batteries
- 1 x Instruction Manual

Image: Tovendor Wrist Blood Pressure Monitor U60AH and its package contents.
3. Product Features
- Large LCD Backlight Display: Provides clear readings of systolic pressure, diastolic pressure, and pulse rate, even in low light conditions.
- Fast Reading: Delivers accurate measurements within approximately 35 seconds.
- Dual User Mode: Supports data storage for two individual users.
- Memory Function: Stores up to 90 sets of data for each user (total 180 readings), allowing for tracking of health status over time.
- Compact and Portable: Includes a durable carrying case for convenient travel and storage.
- Clinical Accuracy: Undergone clinical testing and verification to ensure measurement accuracy.

Image: Key features displayed on the monitor screen.

Image: Large LCD screen with bright backlight for clear display day or night.
4. Setup
4.1 Battery Installation
- Open the battery compartment cover on the back of the device.
- Insert the two AAA batteries, ensuring the polarity (+ and -) matches the diagrams inside the compartment.
- Close the battery compartment cover securely.
4.2 Initial Setup
After installing batteries, the device may prompt for date and time settings. Follow the on-screen instructions to set these parameters for accurate record-keeping.
5. Operating Instructions
5.1 Before Measurement
- Rest for at least 5-10 minutes before taking a measurement.
- Avoid eating, drinking alcohol, smoking, or exercising for 30 minutes prior to measurement.
- Ensure your bladder is empty.
5.2 Correct Measurement Posture
Proper posture is crucial for accurate readings:
- Sit comfortably on a chair with your back straight and feet flat on the floor.
- Place your left wrist on a table or other flat surface.
- Ensure the monitor is at the same level as your heart.
- Keep your wrist still and relaxed during the measurement.

Image: Correct posture for accurate measurement.
5.3 Applying the Wrist Cuff
- Remove any tight clothing or accessories from your left wrist.
- Slide the cuff onto your left wrist with the display facing upwards.
- Adjust the cuff so it is snug but not too tight, leaving a gap of approximately 0.4 inches (1 cm) between the cuff and your hand.
5.4 Taking a Measurement
- Once the cuff is correctly positioned and you are in the proper posture, press the START/STOP button.
- The cuff will automatically inflate and then slowly deflate. Remain still and silent during this process.
- The systolic pressure, diastolic pressure, and pulse rate will be displayed on the screen.
5.5 Dual User Mode and Memory
The device supports two users. To switch between User 1 and User 2, press the user selection button (often indicated by two person icons). Each user can store up to 90 readings. To view past readings, press the MEM button. Repeated presses will cycle through stored measurements.

Image: Dual user mode display.

Image: Function display with labeled indicators.
6. Maintenance
6.1 Cleaning
Wipe the device and cuff gently with a soft, dry cloth. If necessary, use a cloth lightly dampened with water or a mild detergent, then wipe dry. Do not use abrasive cleaners or immerse the device in water.
6.2 Storage
Store the monitor in its protective carrying case when not in use. Keep it in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity. Remove batteries if the device will not be used for an extended period.
7. Troubleshooting
If you encounter issues with your blood pressure monitor, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No display/Device won't turn on | Dead or incorrectly installed batteries. | Replace batteries with new ones, ensuring correct polarity. |
| Inaccurate readings | Incorrect cuff placement, improper posture, movement during measurement, or recent activity. | Ensure cuff is correctly placed, maintain proper posture, remain still and silent, and rest for 5-10 minutes before measuring. |
| Cuff does not inflate | Cuff not properly attached or air leakage. | Check cuff connection and ensure it is securely wrapped around the wrist. |
| Error message on display | Various operational errors. | Refer to the specific error code in the full instruction manual (if available) or try restarting the device. If the problem persists, contact customer support. |
8. Specifications
- Model Number:
- U60AH
- Product Dimensions:
- 3.54 x 3.93 x 3.54 inches
- Item Weight:
- 8.47 ounces
- Power Source:
- Battery Powered (2 x AAA batteries)
- Display Type:
- Digital LCD
- Target Use Body Part:
- Wrist
- Memory Capacity:
- 2 users, 90 readings each (180 total)
- Manufacturer:
- SHENZHEN URION TECHNOLOGY CO., LTD.
9. Warranty and Support
For warranty information, technical support, or any questions regarding your Tovendor Wrist Blood Pressure Monitor U60AH, please refer to the contact details provided in the original packaging or visit the official Tovendor website. Keep your purchase receipt as proof of purchase for warranty claims.