1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity K2 CP 10 kW wood stove. Please read these instructions carefully before using the appliance and retain them for future reference. Proper adherence to these guidelines will ensure optimal performance and longevity of your stove.

Image 1: Front view of the Prity K2 CP wood stove with a visible fire through the ceramic glass door.
1.1 Product Overview
The Prity K2 CP is a 10 kW wood-burning stove designed for heating residential spaces. It features a robust construction with a reinforced combustion chamber lined with refractory bricks for heat accumulation and improved combustion temperature. The stove is equipped with heat-resistant ceramic glass, a cast iron grate, and two manual dampers for precise air and flame intensity control. An integrated compartment is provided for storing and drying wood.
1.2 Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.
- Always ensure adequate ventilation in the room where the stove is installed.
- Maintain required clearances to combustible materials as specified in local building codes and this manual.
- Only use recommended fuels (wood, coal). Do not burn plastics, treated wood, or other unsuitable materials.
- Regularly inspect and clean the flue system to prevent creosote buildup and chimney fires.
- Keep children and pets away from the hot surfaces of the stove.
- Install smoke and carbon monoxide detectors in your home.
2. Setup and Installation
Installation must be performed by a qualified professional and comply with all local and national building and fire safety regulations.
2.1 Unpacking and Inspection
Carefully unpack the stove and inspect it for any damage that may have occurred during transit. Report any damage to your supplier immediately. Ensure all components listed in the packing list are present.
2.2 Location and Clearances
Choose a suitable location for the stove, ensuring it is on a non-combustible floor or hearth. Maintain the minimum clearances to combustible walls and materials as specified by local regulations and the manufacturer. The flue pipe connection is at the top of the stove.

Image 2: Prity K2 CP wood stove displaying Ecodesign 2022 and Blm SchV2 certifications, indicating compliance with environmental standards.
2.3 Flue System Connection
Connect the stove to a suitable chimney or flue system with a diameter of 130 mm. Ensure all connections are sealed properly to prevent smoke leakage. The chimney must be in good condition, free of obstructions, and capable of providing adequate draft.
2.4 Initial Firing (Curing)
Before regular use, the stove must be cured to allow the paint and internal components to settle. This process involves several small, low-temperature fires. During curing, some smoke and odor may be emitted; ensure the area is well-ventilated. Avoid high temperatures during the first few fires.
3. Operating Instructions
Understanding how to properly operate your Prity K2 CP stove is crucial for safety, efficiency, and comfort.
3.1 Fuel Type
The Prity K2 CP stove is designed to burn wood and coal. For optimal performance and to minimize creosote buildup, use dry, seasoned hardwood. Wood with a moisture content of 20% or less is recommended. Avoid burning:
- Wet or unseasoned wood
- Garbage, plastics, or chemical waste
- Treated or painted wood
- Flammable liquids
3.2 Lighting the Stove
- Open both the front air supply damper and the smoke damper fully.
- Place crumpled paper or natural firelighters on the cast iron grate.
- Add a small amount of kindling (small, dry pieces of wood) on top of the firelighters.
- Light the firelighters.
- Once the kindling is burning well, gradually add larger pieces of wood.
- Close the combustion chamber door once the fire is established.
3.3 Air Control
The stove is equipped with two manual dampers:
- Front Air Damper: Located at the front, this controls the primary air supply to the combustion chamber. Open it for ignition and when adding new fuel. Close it partially to reduce the burn rate and conserve fuel.
- Smoke Damper: This regulates the intensity of the flame and the draft through the flue. Adjust it to achieve a steady, efficient burn.
Adjusting these dampers allows you to control the heat output and efficiency. A bright, lively flame indicates good combustion. Excessive smoke or a dull, smoldering fire suggests insufficient air or wet fuel.
3.4 Refueling
When adding more fuel, open the front air damper and smoke damper fully for a few minutes before opening the combustion chamber door. This helps to prevent smoke from entering the room. Carefully place new logs onto the existing embers and close the door. Adjust the dampers once the new fuel has ignited.
4. Maintenance
Regular maintenance is essential for the safe and efficient operation of your Prity K2 CP stove.
4.1 Ash Removal
Remove ash regularly from the ash pan, typically when it is about two-thirds full. Do not allow ash to build up and touch the bottom of the grate, as this can restrict airflow and damage the grate. Always use a metal container with a tight-fitting lid for ash disposal, as embers can remain hot for days.
4.2 Glass Cleaning
The ceramic glass in the combustion chamber door can become dirty with soot. Clean it when the stove is cold using a specialized glass cleaner for wood stoves or a damp cloth dipped in ash. Avoid abrasive cleaners or tools that could scratch the glass.
4.3 Flue and Chimney Cleaning
The flue pipe and chimney should be inspected and cleaned at least once a year, or more frequently depending on usage and fuel type. Creosote buildup is a fire hazard. This task should be performed by a certified chimney sweep.
4.4 General Inspection
Periodically check the door seals for wear and tear. Replace them if they are damaged to ensure an airtight seal. Inspect the refractory bricks for cracks or damage; while minor cracks are normal, severely damaged bricks should be replaced.
5. Troubleshooting
This section addresses common issues you might encounter with your wood stove.
| Problem | Possible Cause | Solution |
|---|---|---|
| Smoke entering the room | Insufficient draft, blocked chimney, opening door too quickly, wet fuel. | Check chimney for blockages, ensure dampers are open, pre-heat flue, use dry fuel, open door slowly. |
| Poor heat output | Wet fuel, insufficient air, stove too small for space, excessive ash. | Use dry fuel, adjust air dampers, remove ash, ensure stove size is appropriate. |
| Rapid burning of fuel | Too much air supply, faulty door seal. | Close air dampers partially, check and replace door seals if necessary. |
| Glass blackens quickly | Wet fuel, low burning temperature, insufficient air wash. | Use dry fuel, ensure adequate air supply, clean glass regularly. |
6. Specifications
Technical data for the Prity K2 CP 10 kW Wood Stove.
| Feature | Value |
|---|---|
| Brand | Prity (BALKAN ENERGY) |
| Model | K2 CP |
| Product Dimensions (H x W x D) | 810 x 500 x 510 mm |
| Combustion Chamber Dimensions (H x W x D) | 400 x 365 x 410 mm |
| Heating Power | 10 kW |
| Heating Surface Area | Approx. 57 m² |
| Efficiency | 75-80% |
| Flue Pipe Diameter | 130 mm |
| Flue Position | Top |
| Fuel Type | Wood, Coal |
| Material | Stainless Steel (Body), Cast Iron (Grate, Top Plate), Ceramic Glass |
| Color | Graphite Black |
| Weight | 90 kg |
| Energy Class | A |
| Certification | CE, EN Standard |
| EPREL Registration Number | 1271282 |
7. Warranty and Support
For warranty information, technical support, or spare parts, please contact the manufacturer or your retailer.
- Manufacturer: Prity 95 Ltd.
- Website: www.prity-bg.com
- Email: prity95@live.com
- Phone: +359 884 941 948
- Address: 33 "Maksim Raykovich" Str, 5140 Lyaskovets, BULGARIA
- EPREL Product Information: View EPREL Database
Please have your model number (K2 CP) and purchase date available when contacting support.