1. Introduction
This manual provides detailed instructions for the installation and use of the Bixegg WE25X217 Liquid Propane (LP) Conversion Kit. This kit is designed to convert compatible GE, Hotpoint, and RCA gas dryers from natural gas to liquid propane operation. Please read all instructions carefully before proceeding with installation to ensure safe and proper operation.
2. Safety Information
WARNING: Gas appliance conversion should only be performed by a qualified service technician. Failure to follow these instructions exactly may result in fire, explosion, or carbon monoxide poisoning, causing property damage, personal injury, or death. Always disconnect power and gas supply to the dryer before beginning any work.
Ensure adequate ventilation during and after installation. Check for gas leaks using a non-corrosive leak detection solution after conversion. Never use an open flame to check for leaks.

3. Product Components
The WE25X217 Liquid Propane Conversion Kit includes the following components:
- #55 LP Gas Orifice
- Regulator Blocker
- Conversion Rating Plate
- Valve Conversion Decal
- Responsibility Label
- Instruction Sheet (this manual)


4. Compatibility
This conversion kit is compatible with most GE, Hotpoint, and RCA type 1 clothes dryers (excluding international models) that use a Galve valve model 25M01A type 176, with base part number 964D498G.
Refer to the following image for a list of compatible GE and Hotpoint dryer models:

5. Installation Instructions
Before You Begin: Ensure the dryer is disconnected from electrical power and the natural gas supply is shut off. Allow the dryer to cool completely if it has been in use. It is highly recommended that this procedure be performed by a qualified technician.
- Access the Gas Valve: Carefully move the dryer away from the wall. Locate and access the gas valve assembly, typically found at the rear or bottom of the dryer.
- Remove Natural Gas Orifice: Using an appropriate wrench, carefully remove the existing natural gas orifice from the gas valve.
- Install LP Gas Orifice: Thread the #55 LP Gas Orifice into the gas valve. Ensure it is securely tightened to prevent leaks.
- Install Regulator Blocker: Insert the regulator blocker into the designated slot on the gas regulator. This prevents the regulator from operating on natural gas pressure.
- Apply Labels and Decals: Affix the "Conversion Rating Plate" and "Valve Conversion Decal" to the dryer in a visible location, indicating that the appliance has been converted to LP gas. Apply the "Responsibility Label" as instructed.
- Check for Leaks: After reassembling the dryer and reconnecting the LP gas supply, perform a thorough leak check using a non-corrosive leak detection solution on all gas connections.
- Test Operation: Restore electrical power and test the dryer's operation to ensure proper ignition and flame characteristics with LP gas.
For a visual guide, please refer to the following videos demonstrating the conversion process:
Video 5.1: Overview of the GE WE25X217 OEM Propane Conversion Kit and its components.
Video 5.2: Demonstration of the GE WE25X217 Genuine OEM Liquid Propane Conversion Kit installation steps.


6. Operating Instructions
After successful conversion and leak testing, operate your dryer according to its original manufacturer's instructions for LP gas appliances. Ensure the flame is stable and blue, indicating proper combustion.
7. Maintenance
This conversion kit requires no specific maintenance beyond the regular maintenance recommended for your gas dryer. Periodically inspect gas connections for any signs of wear or leaks. If any issues are detected, immediately shut off the gas supply and contact a qualified service technician.
8. Troubleshooting
If your dryer does not operate correctly after conversion, or if you suspect a gas leak, immediately shut off the gas supply and disconnect power to the appliance. Contact a qualified service technician for diagnosis and repair. Do not attempt to troubleshoot gas-related issues yourself.
Common issues after conversion may include:
- No ignition: Check gas supply, ensure all connections are secure, and verify the LP orifice is correctly installed.
- Yellow or unstable flame: This indicates improper combustion. Immediately shut off gas and power and contact a professional.
- Gas odor: Immediately shut off gas and power, ventilate the area, and contact emergency services and a qualified technician.
9. Specifications
| Feature | Detail |
|---|---|
| Brand | Bixegg |
| Model Number | WE25X217 |
| Item Weight | 1.44 Ounces |
| Color | Silver and Gold |
| Included Components | #55 LP Gas Orifice, Regulator Blocker, Conversion Rating Plate, Valve Conversion Decal, Responsibility Label, Instruction Sheet |
| UPC/GTIN | 768350534872 |

10. Warranty and Support
This product is offered with a 30-day return policy for any reason. For returns or support inquiries, please refer to your purchase platform's return process or contact the seller directly.