ACR PLB-410 RLS

ACR ResQLink 410 RLS Personal Locator Beacon User Manual

Introduction

The ACR ResQLink 410 RLS is a compact, buoyant personal locator beacon designed to alert search and rescue services in emergency situations. It features Return Link Service (RLS), GPS, Galileo GNSS, and MEOSAR compatibility for global coverage and accurate positioning. This manual provides essential information for the proper setup, operation, and maintenance of your ResQLink 410 RLS.

ACR ResQLink 410 RLS Personal Locator Beacon
The ACR ResQLink 410 RLS Personal Locator Beacon, a compact device for emergency signaling.

Product Overview Video

This video provides an overview of the new ACR ResQLink RLS Personal Locator Beacons, highlighting their key features and benefits.

Setup

Registration

Before initial use, it is mandatory to register your ACR ResQLink 410 RLS with the appropriate national authority (e.g., NOAA in the USA). Registration ensures that search and rescue services have access to your emergency contact information and vessel details, which is crucial for a timely and effective rescue. Failure to register may delay rescue efforts. Follow the instructions provided in the packaging or visit the manufacturer's website for detailed registration steps.

Battery Installation/Check

The ResQLink 410 RLS comes with two Lithium Metal batteries pre-installed. These batteries have a 5-year life. Regularly check the battery expiration date printed on the device. If the battery is nearing its expiration or has been activated, it must be replaced by an authorized service center to ensure proper functionality.

Initial Activation Test

It is recommended to perform a self-test upon receiving your beacon and periodically thereafter to ensure it is functioning correctly. Refer to the 'Self-Test Function' in the Operating Instructions section for detailed steps.

Activation Guide Video

This video demonstrates the activation process for ACR ResQlink 400 and 425 series PLBs, which is similar to the 410 RLS model.

Operating Instructions

Emergency Activation

  1. Deploy Antenna: Slide the antenna cover to expose and fully extend the antenna. Ensure it is positioned at a 90-degree angle to the device, pointing towards the sky.
  2. Activate Beacon: Press and hold the 'ON' button for approximately 2 seconds until the red LED light begins to flash and the strobe light activates. The device will immediately begin to acquire GPS coordinates.
  3. Confirm RLS: Once GPS is acquired, the red LED light will turn green, indicating that your distress message has been sent and Return Link Service (RLS) confirmation is being processed.
  4. Maintain Position: Keep the beacon in an open area with a clear view of the sky until rescue personnel arrive. Do not turn it off until you have been rescued.
ACR ResQLink 410 RLS in hand
The ACR ResQLink 410 RLS held in hand, ready for deployment.

Deactivation

To deactivate the beacon, press and hold the power button for 3 seconds. The device will power off. Once deactivated, retract the antenna and secure the cover.

Self-Test Function

The self-test function allows you to verify the beacon's operational status without sending a distress signal. To perform a self-test, ensure the antenna is deployed, then press the 'TEST' button (often indicated by a 'T' or checkmark) for 1 second. The display will show 'TEST' and then 'GPS' as it attempts to acquire a signal. A successful test will typically show 'PASS' or a green light, indicating the beacon is ready for use.

Maintenance

To ensure your ResQLink 410 RLS remains in optimal working condition, perform regular checks:

Troubleshooting

No GPS Signal Acquisition

Ensure the beacon has a clear, unobstructed view of the sky. Obstructions like dense foliage, buildings, or being inside a vessel can prevent GPS signal acquisition. Move to an open area if possible.

Beacon Not Activating

Verify that the antenna is fully deployed and the activation button is pressed and held for the specified duration (typically 2 seconds for activation). Check the battery status if the device fails to respond.

False Alarms

If the beacon is accidentally activated, immediately deactivate it by pressing and holding the power button for 3 seconds. Contact your national search and rescue authority (e.g., NOAA) to report the false alarm and prevent unnecessary deployment of resources.

Specifications

FeatureDetail
Product Dimensions4.52 x 2.03 x 1.49 inches
Item Weight1 pounds
Item Model NumberPLB-410 RLS
Batteries2 Lithium Metal batteries required (included)
Connectivity TechnologiesRF
GPSGPS Enabled
Special FeaturesReturn Link Service
Human Interface InputButtons
ColorBlack, Yellow
What's in the BoxBelt Clip, PFD Oral Inflation Tube Clip, Attachment Strap
ManufacturerACR Electronics
Date First AvailableJune 14, 2022

Warranty Information

The ACR ResQLink 410 RLS typically comes with a manufacturer's warranty. For specific details regarding warranty coverage, duration, and claims procedures, please refer to the official warranty documentation included with your product or visit the ACR Electronics website. Keep your proof of purchase for warranty purposes.

Support & Contact

For technical assistance, product inquiries, or to report an emergency beacon activation, please contact ACR Electronics customer support. You can find contact information on the official ACR Electronics website.

ACR Electronics Official Website: www.acrartex.com

Related Documents - PLB-410 RLS

Preview ACR ResQLink PLB Installation Guide for Atlas 190 UML Life Jacket
Step-by-step instructions for fitting an ACR ResQLink Personal Locator Beacon (PLB) to an Atlas 190 UML Life Jacket, ensuring safe and correct functionality.
Preview ACR ResQlink AIS Fitting Instructions for Atlas 190 Hammar Life Jacket
Step-by-step guide for fitting an ACR ResQlink AIS Personal Locator Beacon (PLB) to a Mustang Survival Atlas 190 Hammar Life Jacket, ensuring correct and safe installation for emergency situations.
Preview Instructions for ACR AISLink MOB to ELITE 190 Inflatable PFD
Step-by-step guide on how to fit an ACR AISLink MOB device to an ELITE 190 Inflatable PFD, ensuring safe and correct function.
Preview ACR RCL-300A Searchlight Mounting and Installation Guide
Comprehensive guide for mounting and installing the ACR RCL-300A searchlight system, including URC-300 Master Controller and URP-102 Point Pad, with detailed wiring instructions and features.
Preview ACR Electric SEREN Stove Installation and User Manual
Comprehensive installation and user manual for the ACR Electric SEREN stove range (SEREN-70, SEREN-130, SEREN-150), covering setup, operation, maintenance, troubleshooting, and warranty information.
Preview ACR Committee on Training (COT) Subcommittees Overview
Details on the E-Learning, Educator Resources, Pediatric Training, and Fellows in Training Subcommittees of the ACR Committee on Training (COT), including term commitments, charges, member commitments, and eligibility requirements.