Vitrifrigo ND35 OR-V

Vitrifrigo ND35 OR-V Refrigerant Cooling Unit User Manual

Model: ND35 OR-V

1. Introduction

1.1 Overview

This user manual provides essential information for the safe and efficient operation, installation, and maintenance of your Vitrifrigo ND35 OR-V refrigerant cooling unit. Please read this manual thoroughly before installing or operating the unit to ensure proper function and to prevent damage or injury.

1.2 Safety Instructions

  • Always disconnect power before performing any installation, maintenance, or troubleshooting.
  • Installation and service should only be performed by qualified personnel.
  • Ensure adequate ventilation around the unit to prevent overheating.
  • Do not modify the unit or its components. Unauthorized modifications can lead to malfunction and void the warranty.
  • Handle refrigerant lines with care. Avoid kinking or damaging them.
  • This unit operates under nitrogen pressure. Exercise caution when handling.

2. Product Description

The Vitrifrigo ND35 OR-V is a compact refrigerant cooling unit designed for creating refrigerated spaces up to 300 liters and freezer compartments up to 100 liters. It operates primarily on 12/24 VDC and is supplied pre-charged with refrigerant under nitrogen pressure. The unit is designed for versatility, with options for quick couplings and additional power supply compatibility for 100/240 VAC.

Key features include:

  • Compact compressor-based cooling system.
  • Operates on 12/24 VDC standard.
  • Suitable for refrigeration up to 300 liters and freezing up to 100 liters.
  • Supplied under nitrogen pressure (without quick couplings).
  • Optional AC power supply via electronic control unit (12-24 / 100-240 VAC 50/60 Hz) or external self-switching power supply.
Vitrifrigo ND35 OR-V Refrigerant Cooling Unit

An image showing the compact design of the Vitrifrigo ND35 OR-V refrigerant cooling unit, featuring its compressor, copper tubing, and electrical connections.

3. Setup

3.1 Unpacking and Inspection

Carefully remove the unit from its packaging. Inspect for any signs of shipping damage. Report any damage to your supplier immediately. Retain packaging for future transport or storage.

3.2 Mounting the Unit

The ND35 OR-V is designed for freestanding installation. Choose a location that is dry, well-ventilated, and protected from direct sunlight or excessive heat sources. Ensure there is sufficient space around the unit for air circulation, especially around the condenser coils. Secure the unit using appropriate fasteners to prevent movement during operation.

3.3 Electrical Connection

The unit operates on 12/24 VDC. Connect the positive (+) and negative (-) terminals to a stable DC power source, ensuring correct polarity. Use appropriately sized wiring to prevent voltage drop, especially over longer distances. For optional 100/240 VAC operation, connect the electronic control unit or external self-switching power supply according to its specific instructions. Always ensure the power source matches the unit's requirements.

4. Operating Instructions

4.1 Initial Startup

After installation and electrical connection, apply power to the unit. The compressor should start. Allow the unit to run for several hours to reach the desired temperature before loading the compartment with items.

4.2 Temperature Control

Temperature control is typically managed by an external thermostat or control panel connected to the unit (not included with the basic ND35 OR-V unit). Refer to the instructions for your specific thermostat or control system for setting and adjusting temperatures.

4.3 Power Supply Options

The unit automatically adapts to 12V or 24V DC input. If using the optional AC power supply, ensure the correct voltage (100-240 VAC) is provided. The electronic control unit or external power supply will convert the AC to the appropriate DC voltage for the compressor.

5. Maintenance

5.1 Regular Cleaning

Keep the condenser coils clean and free of dust and debris. A build-up of dirt can reduce cooling efficiency and increase power consumption. Use a soft brush or vacuum cleaner to gently remove dust. Ensure the unit is disconnected from power before cleaning.

5.2 System Checks

Periodically check all electrical connections for tightness and signs of corrosion. Inspect refrigerant lines for any visible damage or leaks. If a leak is suspected, contact a qualified technician immediately.

5.3 Winterization (if applicable)

If the unit is installed in an environment that will experience freezing temperatures and will not be in use, it is advisable to disconnect power and ensure the system is protected from extreme cold, although the unit itself is designed for robust operation.

6. Troubleshooting

Before contacting service, please check the following common issues:

ProblemPossible CauseSolution
Unit not coolingNo power; Insufficient ventilation; Refrigerant leak; Faulty thermostatCheck power connection/fuse; Clear obstructions around condenser; Contact technician; Check thermostat settings
Compressor runs continuouslyHigh ambient temperature; Door/lid not sealed; Overloaded compartment; Thermostat set too lowImprove ventilation; Check door seal; Reduce load; Adjust thermostat setting
Unusual noiseLoose mounting; Fan obstruction; Internal component issueCheck mounting screws; Clear fan area; Contact technician

7. Specifications

AttributeValue
ManufacturerVitrifrigo
Model ReferenceND35 OR-V
Cooling Capacity (Max)Up to 300 Liters (refrigeration)
Freezing Capacity (Max)Up to 100 Liters (freezer)
Power Supply (Standard)12/24 VDC
Power Supply (Optional)100-240 VAC (with electronic control unit/external power supply)
Installation TypeFreestanding
Form FactorCompact
Defrost SystemAutomatic
Cooling MethodCompressor

8. Warranty and Support

Vitrifrigo products are manufactured to high quality standards and come with a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Vitrifrigo website.

For technical support, spare parts, or service inquiries, please contact your authorized Vitrifrigo dealer or the customer service department. When contacting support, please have your model number (ND35 OR-V) and purchase information readily available.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.