VEVOR AIR COOLED WATER CHILLER

VEVOR AIR COOLED WATER CHILLER Instruction Manual

Model: AIR COOLED WATER CHILLER

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, maintenance, and troubleshooting of your VEVOR Industrial Air-Cooled Water Chiller. Please read this manual thoroughly before operating the equipment and retain it for future reference.

Safety Precautions

  • Ensure the chiller is installed on a stable, level surface.
  • Verify that the power supply matches the chiller's voltage requirements (440V).
  • Do not operate the chiller without proper grounding.
  • Keep the area around the chiller clear to ensure adequate ventilation.
  • Only qualified personnel should perform maintenance or repairs.

2. Product Overview

The VEVOR Industrial Air-Cooled Water Chiller is designed for efficient cooling applications, featuring a 60L capacity, 9.4Hp compressor, finned condenser, and micro-computer control. It is built with a stainless steel water tank for durability and reliable performance.

VEVOR Industrial Air-Cooled Water Chiller

Image 2.1: Front and side view of the VEVOR Industrial Air-Cooled Water Chiller, showcasing its robust design and control panel.

Key Features

  • Fast Cooling: Efficiently delivers 15100 Kcal/h cooling capacity.
  • Rapid Heat Dissipation: Equipped with a finned condenser and powerful fans.
  • Low Noise Operation: Designed for reduced operational sound.
  • Intelligent Microcomputer Program: Provides precise temperature control within 5°C to 30°C.
  • Six Security Protections: Includes phase loss, reverse, motor overload, high/low voltage, automatic water replenishment, and coil overheating protection.
VEVOR Chiller with features: Fast Cooling, Rapid Heat Dissipation, Low Noise

Image 2.2: Visual representation of the chiller's core benefits: fast cooling, rapid heat dissipation, and low noise operation.

VEVOR Chiller with Six Security Protections listed

Image 2.3: Diagram illustrating the six integrated security protection features of the chiller, ensuring stable and safe operation.

Internal components of VEVOR Chiller: Powerful Fan, Premium Condenser, High-pressure Water Pump, 16 Gal Water Tank

Image 2.4: Internal view highlighting key components such as the powerful fan, premium condenser, high-pressure water pump, and the 16-gallon water tank, all contributing to efficient cooling.

3. Setup

3.1 Placement

Place the chiller indoors on a firm, level surface. Ensure there is sufficient clearance (at least 50 cm) around the unit for proper airflow and heat dissipation, especially for the air intake and exhaust vents.

3.2 Electrical Connection

  • Confirm that the local power supply matches the chiller's rated input voltage of 440V/60Hz.
  • Connect the chiller to a dedicated, grounded power outlet using the provided 5-wire connector.
  • Ensure all electrical connections are secure and comply with local electrical codes.

3.3 Water Connections

Connect the water inlet, outlet, and supply lines to your external equipment as required. Ensure all connections are tight to prevent leaks.

Diagram showing water inlet, outlet, and supply connections on the VEVOR Chiller, and a 5-wire connector

Image 3.1: Illustration of the water inlet, outlet, and supply ports, along with the 5-wire electrical connector, simplifying the connection process to external equipment.

3.4 Initial Water Filling

Fill the chiller's stainless steel water tank (16 gallons / 60 liters capacity) with clean, deionized water or a recommended coolant solution. Monitor the water level indicator and ensure it is within the recommended range.

VEVOR Chiller with 360-degree self-locking silent wheels

Image 3.2: The chiller features 360-degree self-locking silent wheels for easy movement and secure positioning. Two wheels include locking pedals for added stability.

4. Operation

4.1 Control Panel

The chiller is equipped with a micro-computer control panel for precise temperature management. The panel displays the current temperature, allows for setting adjustments, indicates faults, and shows the operating status.

VEVOR Chiller's multi-functional LED control panel showing temperature display, setting adjustment, fault indication, and operating status display

Image 4.1: Close-up of the multi-functional LED control panel, detailing its capabilities for temperature display, setting adjustments, fault indications, and operating status monitoring.

4.2 Temperature Setting

  • Use the control panel to set the desired cooling temperature within the range of 5°C to 30°C.
  • Refer to the specific instructions on the control panel for navigating menus and adjusting settings.
VEVOR Chiller with a dial indicating working temperature range of 5-30°C

Image 4.2: Graphic illustrating the intelligent microcomputer program's precise temperature control, allowing operation within a 5-30°C range.

4.3 Monitoring

The chiller includes dual pressure gauges for comprehensive system monitoring. Regularly check these gauges to diagnose and maintain the system effectively.

Close-up of the VEVOR Chiller's dual pressure gauges: High Pressure Gauge and Low Pressure Gauge

Image 4.3: Detailed view of the dual pressure gauges (high and low pressure) for comprehensive system monitoring and diagnosis.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your VEVOR Water Chiller.

5.1 Cleaning the Condenser

Periodically clean the finned condenser to remove dust and debris. A clogged condenser reduces cooling efficiency and increases energy consumption. Use a soft brush or compressed air.

5.2 Water Quality

Regularly check the quality of the water in the tank. Replace or filter the water as needed to prevent scale buildup and corrosion within the system. Use deionized water or a recommended coolant solution.

5.3 General Inspection

  • Inspect all hoses and connections for leaks.
  • Check electrical wiring for any signs of wear or damage.
  • Ensure all fans are operating correctly and without obstruction.

6. Troubleshooting

This section provides guidance for common issues. For complex problems, contact VEVOR customer support.

Common Issues and Solutions

  • Chiller Not Cooling: Check power supply, water level, and ensure condenser is clean. Verify temperature settings.
  • Error Codes on Display: Refer to the control panel's specific error code manual (if provided separately) or contact support with the displayed code.
  • Water Leaks: Inspect all connections and hoses. Tighten or replace as necessary.
  • Unusual Noise: Check for loose components, fan obstructions, or abnormal compressor operation.

7. Specifications

Detailed technical specifications for the VEVOR Industrial Air-Cooled Water Chiller.

VEVOR Chiller dimensions and specifications table

Image 7.1: Visual representation of the chiller's dimensions and a summary of its key technical specifications.

SpecificationValue
Item Model NumberAIR COOLED WATER CHILLER
Rated Input Voltage440 V/60 Hz
Control Temperature5°C to 30°C
Condensation Temperature40°C
Operating Ambient Temperature≤40°C
Compressor TypeFully Enclosed Scroll
Compressor Motor Power6 HP/4.5 kW
Fan Power0.55 kW
Pump Power0.37 kW
Water Tank Capacity16 gal / 60 L
Refrigeration Capacity15100 Kcal/h
Net Weight430 lbs / 195 kg ± 2%
Product Dimensions (L x W x H)56.3 x 45.3 x 23.6 inches (1430 x 1150 x 600 mm)

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact VEVOR customer service. Keep your purchase receipt and product model number handy when contacting support.

Visit the official VEVOR website for the latest support resources and contact details.