MokerLink 48xGE + 2SFP

MokerLink 48 Port Gigabit Ethernet Switch User Manual

Model: 48xGE + 2SFP

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the MokerLink 48 Port Gigabit Ethernet Switch (Model: 48xGE + 2SFP). This unmanaged network switch is designed for high-performance data transmission in various network environments, from home offices to data centers.

Key Features:

2. Package Contents

Verify that all items listed below are present in your product package. If any items are missing or damaged, please contact MokerLink support.

3. Product Overview

Familiarize yourself with the physical components and indicators of the MokerLink 48 Port Gigabit Ethernet Switch.

3.1 Front Panel

Front view of the MokerLink 48 Port Gigabit Ethernet Switch

Image Description: This image displays the front panel of the MokerLink 48 Port Gigabit Ethernet Switch. It features 48 RJ45 Gigabit Ethernet ports and 2 SFP ports. On the left side, there are LED indicators for power and data activity for each port. The overall design is a black, rectangular metal chassis suitable for rack mounting.

3.2 Rear Panel

Rear view of the MokerLink 48 Port Gigabit Ethernet Switch showing dual power inputs

Image Description: This image shows the rear panel of the MokerLink 48 Port Gigabit Ethernet Switch. It prominently features two power input sockets, highlighting the dual redundant power supply capability. Each socket is a standard IEC C14 inlet for power cords.

4. Setup

Follow these steps to properly set up your MokerLink 48 Port Gigabit Ethernet Switch.

4.1 Physical Installation

The switch can be placed on a desktop or mounted in a standard 19-inch equipment rack.

MokerLink 48 Port Gigabit Ethernet Switch installed in a 19-inch rack

Image Description: This image illustrates the MokerLink 48 Port Gigabit Ethernet Switch mounted within a standard 19-inch server rack. The diagram highlights the 1U height of the switch, demonstrating its compatibility with rack environments.

4.2 Power Connection

Connect the power cords to the switch and a power outlet.

  1. Insert one end of the provided power cords into the power inlets on the rear panel of the switch.
  2. Plug the other end of the power cords into a standard AC power outlet (100-240V, 50-60Hz).
  3. The PWR LED on the front panel will illuminate, indicating that the switch is receiving power.
Diagram showing dual power supply connection to the MokerLink switch

Image Description: This diagram illustrates the dual power supply setup for the MokerLink switch. It shows two power cords connected from a power strip to the two power inlets on the rear of the switch, emphasizing the redundant power feature. The diagram also indicates the power consumption details.

4.3 Network Connection

Connect your network devices to the switch.

  1. Connect Ethernet cables from your network devices (e.g., computers, servers, routers, IP cameras, Wireless Access Points) to any of the 48 Gigabit Ethernet ports (1-48) on the front panel.
  2. For fiber optic connections, insert compatible SFP modules (not included) into the SFP ports (49-50), then connect fiber optic cables to the SFP modules.
  3. Once a device is connected and active, the corresponding Act LED for that port will illuminate and flash during data transmission.
MokerLink 48 Port Gigabit Ethernet Switch with connected Ethernet cables

Image Description: This image shows the MokerLink 48 Port Gigabit Ethernet Switch with multiple yellow Ethernet cables connected to its front panel ports. This visually represents the "Plug and Play" aspect and ease of connecting network devices.

5. Operating Instructions

The MokerLink 48 Port Gigabit Ethernet Switch is an unmanaged device, designed for simple plug-and-play operation.

6. Maintenance

Proper maintenance ensures the longevity and optimal performance of your switch.

7. Troubleshooting

If you encounter issues with your MokerLink switch, refer to the following common troubleshooting steps.

ProblemPossible CauseSolution
No Power (PWR LED Off)
  • Power cord not properly connected.
  • Power outlet not functioning.
  • Faulty power cord.
  • Ensure both power cords are securely plugged into the switch and a working power outlet.
  • Test the power outlet with another device.
  • Try different power cords.
No Link (Act LED Off)
  • Ethernet cable not properly connected.
  • Faulty Ethernet cable.
  • Connected device is off or not functioning.
  • Incorrect port used (e.g., SFP module not inserted).
  • Ensure the Ethernet cable is securely connected to both the switch port and the device.
  • Try a different Ethernet cable.
  • Verify the connected device is powered on and functioning correctly.
  • Ensure SFP modules are correctly inserted for fiber connections.
Slow Network Speed
  • Cable quality or length issues.
  • Network congestion.
  • Connected device limitations.
  • Use high-quality Cat5e/Cat6 or higher Ethernet cables.
  • Ensure cable lengths are within standard limits.
  • Check for other high-bandwidth activities on the network.
  • Verify the capabilities of the connected devices.

If the problem persists after attempting these solutions, please contact MokerLink customer support for further assistance.

8. Specifications

Detailed technical specifications for the MokerLink 48 Port Gigabit Ethernet Switch.

FeatureDescription
Model Number48xGE + 2SFP
Number of Ports48 x Gigabit Ethernet, 2 x Gigabit SFP
Switching Capacity112 Gbps
MAC Address Table Size8K
Jumbo Frame Support9K
Data Transfer Rate1000 Megabits Per Second (per port)
Power SupplyDual Built-in 60W Power Supplies (100-240V AC, 50-60Hz)
Power Consumption (Full Load)≤ 45W
CoolingFanless, Silent Design
Housing MaterialMetal
Dimensions (L x W x H)17.32" x 7.87" x 1.77" (440mm x 200mm x 45mm)
Item Weight8.03 pounds (3.64 kg)
Mounting OptionsDesktop, 19-inch Rackmount
Lightning Protection6KV Port, 1.5KV Power

9. Warranty Information

MokerLink products are designed and manufactured to the highest quality standards. Specific warranty terms and conditions may vary by region and point of purchase.

For detailed warranty information, please refer to the warranty card included with your product, or visit the official MokerLink website. Keep your proof of purchase for warranty claims.

Optional protection plans may be available at the time of purchase.

10. Support

For technical support, product inquiries, or further assistance, please contact MokerLink customer service.