1. Introduction

Thank you for choosing the VOYZ Dynamic Karaoke Microphone VZ-638G. This manual provides essential information for the proper setup, operation, and maintenance of your new microphone. Please read these instructions carefully before use to ensure optimal performance and longevity of the product.

2. Package Contents

Verify that all items listed below are included in your package:

VOYZ VZ-638G Dynamic Karaoke Microphone and included 15ft XLR to 1/4 inch cable

Image: The VOYZ VZ-638G Dynamic Karaoke Microphone shown with its included 15ft XLR to 1/4 inch audio cable.

3. Product Overview

The VOYZ VZ-638G is a handheld dynamic microphone designed for vocal applications, particularly karaoke. It features a durable metal body and an integrated ON/OFF switch for convenient control during use.

Key Features:

Close-up of VOYZ VZ-638G microphone showing the ON/OFF switch

Image: A detailed view of the VOYZ VZ-638G microphone, highlighting the ON/OFF switch located on the microphone body.

Close-up of the microphone grille

Image: A close-up of the microphone's grille, which protects the internal components and contributes to its sound capture.

4. Setup

Follow these steps to connect your VOYZ VZ-638G microphone to your audio system:

  1. Connect the XLR Cable: Take the provided 15ft XLR to 1/4'' audio cable. Connect the XLR (3-pin) end of the cable firmly into the XLR port at the base of the microphone. Ensure it clicks into place securely.
  2. Connect to Audio Input: Plug the 1/4'' (6.35mm) jack end of the cable into the microphone input port of your karaoke machine, mixer, or audio interface. This port is typically labeled "Mic In" or has a microphone icon.
  3. Power On Your Audio Device: Ensure your connected audio device (karaoke machine, mixer) is powered on and its volume is set to a low level before testing the microphone.
Close-up of the 15ft XLR to 1/4 inch audio cable

Image: The 15ft XLR to 1/4 inch audio cable, showing both connector types for proper identification during setup.

VOYZ VZ-638G microphone mounted on a stand and connected via cable

Image: The VOYZ VZ-638G microphone shown connected to an audio cable and mounted on a microphone stand, illustrating a typical setup.

5. Operating Instructions

Using your VOYZ VZ-638G microphone is straightforward:

  1. Turn On the Microphone: Locate the ON/OFF switch on the microphone body. Slide the switch to the "ON" position.
  2. Adjust Volume: Gradually increase the volume on your connected audio device until the desired sound level is achieved. Avoid setting the volume too high initially to prevent feedback or damage to speakers.
  3. Optimal Usage: For best vocal performance, hold the microphone approximately 2-6 inches (5-15 cm) from your mouth. Speak or sing directly into the grille. The unidirectional pattern helps to capture your voice clearly while minimizing ambient noise.
  4. Turn Off After Use: When finished, slide the ON/OFF switch to the "OFF" position before disconnecting the microphone or turning off your audio equipment. This prevents sudden loud noises and protects your equipment.
Hand holding the VOYZ VZ-638G microphone

Image: A hand demonstrating the proper grip for holding the VOYZ VZ-638G microphone during use.

6. Maintenance

Proper care will extend the life of your microphone:

7. Troubleshooting

If you encounter issues with your microphone, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No sound output
  • Microphone switch is OFF
  • Cable not connected properly
  • Audio device volume too low
  • Faulty cable or input port
  • Slide the ON/OFF switch to "ON".
  • Ensure both ends of the cable are securely connected.
  • Increase the volume on your audio device.
  • Test with a different cable or input port if available.
Poor sound quality / Feedback
  • Microphone too far from source
  • Volume too high
  • Microphone pointed incorrectly
  • Hold microphone closer to your mouth (2-6 inches).
  • Reduce the volume on your audio device.
  • Ensure the microphone grille is facing the sound source.

8. Specifications

Technical specifications for the VOYZ VZ-638G Dynamic Karaoke Microphone:

9. Warranty and Support

For warranty information or technical support, please contact VOYZ customer service through their official channels. Retain your proof of purchase for any warranty claims.

WARNING: This product can expose you to lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, please visit the official California Proposition 65 Warnings Website.

Related Documents - VZ-638G

Preview VOYZ Professional Sound Systems & Accessories Catalog 2020 | VOYZ USA
Explore the comprehensive 2020 catalog from VOYZ USA, featuring a wide range of professional sound systems, active and passive line arrays, subwoofers, DJ equipment, and portable speaker solutions designed for superior audio performance.
Preview VERA 26 Cabinet Assembly Guide | Arthauss Furniture
Comprehensive assembly instructions for the Arthauss Furniture VERA 26 cabinet. Includes detailed steps, parts list, hardware identification, and diagrams explained in text. Perfect for DIY furniture assembly.
Preview VERA 51/52 Bed Frame Assembly Instructions | Arthauss Furniture
Detailed assembly instructions for the VERA 51/52 bed frame by Arthauss Furniture. Includes parts list, step-by-step guidance, and service information for replacement parts.
Preview WolfVision Power Supply Guide
A comprehensive guide to WolfVision power supplies, detailing compatibility and specifications for various devices including Visualizers, Cameras, Lightboxes, and Cynap Systems.
Preview WolfVision Power Supply Guide: Visualizers, Cameras, and Cynap Systems
Comprehensive guide to WolfVision power supplies for Visualizers, Cameras, and vSolution Cynap systems, detailing compatibility, specifications, and disposal information.
Preview ViscoPump III: Betriebsanleitung und Technische Daten
Umfassende Anleitung für das Viskositätsmessgerät ViscoPump III von SI Analytics (ein Xylem-Unternehmen), einschließlich technischer Spezifikationen, Inbetriebnahme, Wartung und Fehlerbehebung.