Fire-Lite 4098 - 9714

Fire-Lite 4098-9714 Detector User Manual

Model: 4098-9714

Product Overview

The Fire-Lite 4098-9714 is an analog and addressable photoelectric smoke detector head. It is designed to provide 360-degree smoke entry for optimal response to smoke from any direction. This detector is compatible with Simplex 4010 and 4100U series control panels.

Fire-Lite 4098-9714 Photoelectric Smoke Detector

Figure 1: Front view of the Fire-Lite 4098-9714 photoelectric smoke detector. This image shows the circular white casing with ventilation slots around the perimeter, designed for 360-degree smoke entry.

Important Safety Information

Always read and understand all instructions before installing or operating this device. Failure to follow these instructions may result in property damage, injury, or death. This device operates on 24 volts AC power. Ensure power is disconnected before installation or maintenance.

Setup and Installation

The 4098-9714 detector head is designed to be installed onto a compatible detector base (sold separately). Ensure the base is properly wired to the fire alarm control panel before attaching the detector head.

Installation Steps:

  1. Power Disconnection: Before beginning installation, ensure that all power to the fire alarm control panel and associated circuits is disconnected.
  2. Base Installation: Mount the compatible detector base (e.g., 4098-9792, 4098-9793, 4098-9794) securely to the ceiling or wall according to its specific instructions. Ensure wiring connections to the base terminals are correct and secure.
  3. Detector Head Attachment: Align the 4098-9714 detector head with the installed base. The detector head typically has alignment marks or notches that correspond to the base.
  4. Twist to Lock: Gently push the detector head onto the base and twist clockwise until it clicks into place. This secures the detector and makes the electrical connections.
  5. Power Restoration and Testing: Restore power to the fire alarm control panel. Perform a functional test of the detector as described in the "Operating" section to ensure proper communication and alarm activation.

Operating

The Fire-Lite 4098-9714 is an intelligent addressable detector. Its operation is managed by the connected fire alarm control panel (e.g., Simplex 4010 or 4100U series). The detector continuously monitors for smoke and communicates its status to the control panel.

Status Indicators:

The detector typically includes an LED indicator that provides visual status feedback:

Testing the Detector:

Regular testing is crucial to ensure proper operation. Consult your fire alarm control panel's manual for specific testing procedures. Common methods include:

Always notify relevant authorities and building occupants before conducting tests to avoid false alarms.

Maintenance

Proper maintenance ensures the longevity and reliability of your 4098-9714 detector.

Cleaning:

Replacement:

Smoke detectors have a limited lifespan. The 4098-9714 detector should be replaced according to manufacturer recommendations or local fire codes, typically every 10 years. Refer to the date of manufacture on the detector label.

Troubleshooting

This section provides solutions to common issues. For complex problems, contact a qualified fire alarm technician.

ProblemPossible CauseSolution
Detector not responding / No LED activityNo power; Incorrect wiring; Detector not properly seated on base.Check power to control panel; Verify wiring connections; Ensure detector is twisted and locked onto base.
False alarmsDust/debris in sensing chamber; High humidity; Cooking fumes; Improper placement.Clean the detector (see Maintenance); Relocate if consistently affected by environmental factors.
Trouble signal at control panelDirty detector; Wiring fault; Detector nearing end of life.Clean detector; Check wiring integrity; Consider detector replacement if cleaning does not resolve.

Specifications

Warranty and Support

The Fire-Lite 4098-9714 detector typically comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation provided with your purchase or contact Fire-Lite Alarms directly. For technical support, installation assistance, or troubleshooting beyond this manual, please contact a certified fire alarm system technician or the manufacturer's customer service.

Manufacturer: FIRE-LITE ALARMS

Note: Warranty information provided in the product data was "1", which is not detailed. I will state that the user should refer to the documentation or manufacturer.

Related Documents - 4098 - 9714

Preview Fire-Lite PK-9200W Windows-Based Programming Utility Software Manual
This manual details the Fire-Lite PK-9200W Windows-Based Off-Line Programming Utility software, designed for programming and managing the MS-9200 Addressable Fire Alarm Control Panel. It covers installation, system requirements, software features, and operational procedures for configuring fire alarm systems.
Preview Fire-Lite BB-17F Battery Box Installation Drawing and Guide
Detailed installation drawing and guide for the Fire-Lite BB-17F Battery Box. Learn how to mount and connect the battery box to your Fire Alarm Control Panel (FACP) with step-by-step instructions and parts list.
Preview Manual de Instrucciones y Guía Rápida: Detector de Humo Fotoeléctrico Fire-Lite SD365
Guía rápida y manual de instrucciones para el detector de humo fotoeléctrico direccionable Fire-Lite modelo SD365 y sus variantes. Incluye información de conexión, operación y especificaciones eléctricas.
Preview Fire-Lite MINISCAN 112/124 Fire Alarm Control Panel Instruction Manual
Comprehensive instruction manual for the Fire-Lite MINISCAN 112/124 fire alarm control panel. Details installation, system wiring diagrams, controls, indicators, battery selection, and troubleshooting. Essential guide for system setup and maintenance.
Preview Fire-Lite MS-9200UDLS / MS-9200UDLSE Installation and Programming Manual
Comprehensive manual for the Fire-Lite MS-9200UDLS and MS-9200UDLSE Fire Alarm Control Panels (FACPs) and Digital Alarm Communicator/Transmitters (DACTs), covering installation, programming, and operation for fire protection systems.
Preview Fire-Lite AFM-16AF Annunciator Fixed Module - Technical Manual
Comprehensive technical manual for the Fire-Lite AFM-16AF Annunciator Fixed Module, covering installation, operation, specifications, and warranty for the Sensiscan 2000 Fire Alarm Control Panels.