magree magreepb1g0ed49z2081
magree Auto Pool Dosing Pump Instruction Manual
Model: magreepb1g0ed49z2081
Brand: magree
1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your magree Auto Pool Dosing Pump. This pump is designed for precise chemical dosage and sanitizing in swimming pool environments, ensuring optimal water quality. It is generally used in conjunction with a water quality monitor for automated or semi-automated control.

Image: The magree Auto Pool Dosing Pump positioned near a swimming pool, illustrating a typical installation environment.
2. Safety Information
Please read all safety warnings and instructions carefully before installing or operating the pump. Failure to do so may result in injury or damage to the equipment.
- Always disconnect power before performing any maintenance or service on the pump.
- Ensure the pump is installed in a dry, well-ventilated area, away from direct sunlight and extreme temperatures.
- Handle pool chemicals with extreme care. Always wear appropriate personal protective equipment (PPE) such as gloves and eye protection.
- Do not operate the pump if any part is damaged or if there are signs of leakage.
- Keep the pump out of reach of children and unauthorized personnel.
- Refer to local electrical codes and regulations for proper installation.
3. Package Contents
Verify that all items listed below are included in your package:
- 1 x magree Auto Pool Dosing Pump
- 1 x Set of Connection Fittings (e.g., injectors, filters)
- 1 x Clear Tubing
- 1 x Opaque Tubing

Image: The magree Auto Pool Dosing Pump shown alongside its various components, including tubing and connection fittings.

Image: A detailed view of the connection fittings, including the injector, and the white and beige filters, which are essential for pump operation.
4. Product Overview
The magree Auto Pool Dosing Pump is a robust and efficient device designed for precise chemical injection into your swimming pool system. Its compact design and minimal moving parts contribute to its low maintenance requirements.

Image: A front-angle view of the magree Auto Pool Dosing Pump, highlighting its main body, transparent dosing head, and connection ports.
Key Features:
- High Output: Capable of outputting up to 516 GDP (Gallons per day).
- High Pressure: Supports output pressure up to 125 PSI.
- Adjustable Stroke: Features 4-stroke regulation for small doses at high operating rates.
- Low Maintenance: Simple, high-efficiency design with minimal moving parts.
- Easy Installation: C-600P injector has an autofocus frame and front-side access for easy installation and adjustment.
5. Setup
Follow these steps for the initial setup of your dosing pump:
- Mounting: Securely mount the pump in a suitable location near your pool's circulation system. Ensure it is easily accessible for maintenance and away from direct water spray.
- Tubing Connection: Connect the clear tubing to the suction side of the pump and immerse the other end into your chemical reservoir. Connect the opaque tubing to the discharge side of the pump and route it to the injection point in your pool's plumbing system.
- Electrical Connection: Connect the pump to a suitable power source according to the electrical specifications provided in Section 8. Ensure the power supply is protected by a Ground Fault Circuit Interrupter (GFCI).
- Priming: Before initial operation, prime the pump according to the specific instructions for your chemical type to ensure proper flow and prevent airlocks.
- Integration with Water Quality Monitor (Optional): If using with a water quality monitor, follow the monitor's instructions for connecting and calibrating it with the dosing pump for automated control.


Image: Examples of the clear and opaque tubing used for chemical suction and discharge, respectively.
6. Operating Instructions
Once installed and primed, the magree Auto Pool Dosing Pump is ready for operation. The pump's stroke regulation allows for precise control over chemical dosage.
- Power On: Turn on the power supply to the pump.
- Adjust Dosage: Adjust the stroke regulation setting on the pump to achieve the desired chemical dosage rate. Refer to your pool's chemical requirements and the chemical manufacturer's guidelines.
- Monitor Performance: Regularly monitor the pump's operation and the pool's chemical levels to ensure effective and safe dosing.
- Automatic Control: If connected to a water quality monitor, the pump will automatically adjust its operation based on the monitor's readings.

Image: The magree Auto Pool Dosing Pump, illustrating its robust design suitable for environments where water may be present.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your dosing pump.
- Inspect Tubing: Periodically inspect the suction and discharge tubing for cracks, kinks, or blockages. Replace if necessary.
- Clean Filters: Check and clean the filters on the suction line regularly to prevent debris from entering the pump.
- Check Connections: Ensure all connections are tight and free from leaks.
- Dosing Head Inspection: Inspect the dosing head for any signs of wear or chemical buildup. Clean as needed.
- Winterization: If applicable, follow proper winterization procedures to protect the pump from freezing temperatures. Consult a professional if unsure.
8. Troubleshooting
This section provides solutions to common issues you might encounter with your dosing pump.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump not dosing | No power; Airlock in tubing; Clogged suction filter; Empty chemical reservoir; Damaged tubing. | Check power supply; Prime the pump; Clean or replace filter; Refill reservoir; Inspect and replace tubing. |
| Inconsistent dosing | Partial airlock; Fluctuating power supply; Worn pump components. | Re-prime the pump; Ensure stable power; Contact support for component replacement. |
| Pump making unusual noise | Air in the system; Mechanical issue. | Check for air leaks and prime; Disconnect power and inspect for obstructions; Contact support if noise persists. |
| Chemical leakage | Loose connections; Damaged tubing or seals. | Tighten all connections; Inspect and replace any damaged tubing or seals. |
9. Specifications
| Feature | Specification |
|---|---|
| Maximum Working Pressure | 125 psi (8.6 bar) |
| Maximum Fluid Temperature | 130 ℉ (54 ℃) |
| Operating Temperature Range | 14 ℉ to 110 ℉ / -10℃ to 43 ℃ |
| Output Quantity | Up to 516 GDP (Gallons per day) |
| Stroke Regulation | 4-stroke |
| Model Number | magreepb1g0ed49z2081 |
| Manufacturer | magree |
| Country of Origin | China |
| Style | Above Ground |
| Item Package Quantity | 1 |
10. Warranty and Support
For warranty information and technical support, please refer to the documentation included with your purchase or contact magree customer service directly. Keep your proof of purchase for warranty claims.
For further assistance, please visit the official magree website or contact their customer support line.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.