1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of your magree Auto Pool Dosing Pump. This pump is designed for precise chemical dosage and sanitizing in swimming pool environments, ensuring optimal water quality. It is generally used in conjunction with a water quality monitor for automated or semi-automated control.

magree Auto Pool Dosing Pump installed near a swimming pool

Image: The magree Auto Pool Dosing Pump positioned near a swimming pool, illustrating a typical installation environment.

2. Safety Information

Please read all safety warnings and instructions carefully before installing or operating the pump. Failure to do so may result in injury or damage to the equipment.

  • Always disconnect power before performing any maintenance or service on the pump.
  • Ensure the pump is installed in a dry, well-ventilated area, away from direct sunlight and extreme temperatures.
  • Handle pool chemicals with extreme care. Always wear appropriate personal protective equipment (PPE) such as gloves and eye protection.
  • Do not operate the pump if any part is damaged or if there are signs of leakage.
  • Keep the pump out of reach of children and unauthorized personnel.
  • Refer to local electrical codes and regulations for proper installation.

3. Package Contents

Verify that all items listed below are included in your package:

  • 1 x magree Auto Pool Dosing Pump
  • 1 x Set of Connection Fittings (e.g., injectors, filters)
  • 1 x Clear Tubing
  • 1 x Opaque Tubing
magree Auto Pool Dosing Pump with included accessories

Image: The magree Auto Pool Dosing Pump shown alongside its various components, including tubing and connection fittings.

Close-up of magree dosing pump connection fittings and filters

Image: A detailed view of the connection fittings, including the injector, and the white and beige filters, which are essential for pump operation.

4. Product Overview

The magree Auto Pool Dosing Pump is a robust and efficient device designed for precise chemical injection into your swimming pool system. Its compact design and minimal moving parts contribute to its low maintenance requirements.

Front view of the magree Auto Pool Dosing Pump

Image: A front-angle view of the magree Auto Pool Dosing Pump, highlighting its main body, transparent dosing head, and connection ports.

Key Features:

  • High Output: Capable of outputting up to 516 GDP (Gallons per day).
  • High Pressure: Supports output pressure up to 125 PSI.
  • Adjustable Stroke: Features 4-stroke regulation for small doses at high operating rates.
  • Low Maintenance: Simple, high-efficiency design with minimal moving parts.
  • Easy Installation: C-600P injector has an autofocus frame and front-side access for easy installation and adjustment.

5. Setup

Follow these steps for the initial setup of your dosing pump:

  1. Mounting: Securely mount the pump in a suitable location near your pool's circulation system. Ensure it is easily accessible for maintenance and away from direct water spray.
  2. Tubing Connection: Connect the clear tubing to the suction side of the pump and immerse the other end into your chemical reservoir. Connect the opaque tubing to the discharge side of the pump and route it to the injection point in your pool's plumbing system.
  3. Clear tubing for magree dosing pumpOpaque tubing for magree dosing pump

    Image: Examples of the clear and opaque tubing used for chemical suction and discharge, respectively.

  4. Electrical Connection: Connect the pump to a suitable power source according to the electrical specifications provided in Section 8. Ensure the power supply is protected by a Ground Fault Circuit Interrupter (GFCI).
  5. Priming: Before initial operation, prime the pump according to the specific instructions for your chemical type to ensure proper flow and prevent airlocks.
  6. Integration with Water Quality Monitor (Optional): If using with a water quality monitor, follow the monitor's instructions for connecting and calibrating it with the dosing pump for automated control.

6. Operating Instructions

Once installed and primed, the magree Auto Pool Dosing Pump is ready for operation. The pump's stroke regulation allows for precise control over chemical dosage.

  • Power On: Turn on the power supply to the pump.
  • Adjust Dosage: Adjust the stroke regulation setting on the pump to achieve the desired chemical dosage rate. Refer to your pool's chemical requirements and the chemical manufacturer's guidelines.
  • Monitor Performance: Regularly monitor the pump's operation and the pool's chemical levels to ensure effective and safe dosing.
  • Automatic Control: If connected to a water quality monitor, the pump will automatically adjust its operation based on the monitor's readings.
magree Auto Pool Dosing Pump with water splash effect

Image: The magree Auto Pool Dosing Pump, illustrating its robust design suitable for environments where water may be present.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your dosing pump.

  • Inspect Tubing: Periodically inspect the suction and discharge tubing for cracks, kinks, or blockages. Replace if necessary.
  • Clean Filters: Check and clean the filters on the suction line regularly to prevent debris from entering the pump.
  • Check Connections: Ensure all connections are tight and free from leaks.
  • Dosing Head Inspection: Inspect the dosing head for any signs of wear or chemical buildup. Clean as needed.
  • Winterization: If applicable, follow proper winterization procedures to protect the pump from freezing temperatures. Consult a professional if unsure.

8. Troubleshooting

This section provides solutions to common issues you might encounter with your dosing pump.

ProblemPossible CauseSolution
Pump not dosingNo power; Airlock in tubing; Clogged suction filter; Empty chemical reservoir; Damaged tubing.Check power supply; Prime the pump; Clean or replace filter; Refill reservoir; Inspect and replace tubing.
Inconsistent dosingPartial airlock; Fluctuating power supply; Worn pump components.Re-prime the pump; Ensure stable power; Contact support for component replacement.
Pump making unusual noiseAir in the system; Mechanical issue.Check for air leaks and prime; Disconnect power and inspect for obstructions; Contact support if noise persists.
Chemical leakageLoose connections; Damaged tubing or seals.Tighten all connections; Inspect and replace any damaged tubing or seals.

9. Specifications

FeatureSpecification
Maximum Working Pressure125 psi (8.6 bar)
Maximum Fluid Temperature130 ℉ (54 ℃)
Operating Temperature Range14 ℉ to 110 ℉ / -10℃ to 43 ℃
Output QuantityUp to 516 GDP (Gallons per day)
Stroke Regulation4-stroke
Model Numbermagreepb1g0ed49z2081
Manufacturermagree
Country of OriginChina
StyleAbove Ground
Item Package Quantity1

10. Warranty and Support

For warranty information and technical support, please refer to the documentation included with your purchase or contact magree customer service directly. Keep your proof of purchase for warranty claims.

For further assistance, please visit the official magree website or contact their customer support line.

© 2023 magree. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.