1. Important Safety Information
WARNING: Ultraviolet (UV-C) Radiation Hazard.
- Direct exposure to UV-C light can cause severe eye and skin damage. Never look directly at an illuminated UV-C bulb.
- Ensure the power is disconnected before installing, replacing, or handling the bulb.
- This bulb is designed for use in enclosed fixtures that prevent direct exposure to UV-C radiation. Do not use in open fixtures.
- Keep out of reach of children and pets.
- Dispose of used bulbs according to local regulations for hazardous waste, as they may contain mercury.
2. Product Overview
The Anyray 5W UV-C Germicidal Ultraviolet Replacement Bulb (Model AUVC-5W) is designed for germicidal applications, typically found in water purification systems, air purifiers, or aquarium filters. This bulb emits UV-C light, which is effective in neutralizing bacteria, viruses, and other microorganisms.
Key features include:
- Wattage: 5 Watts
- Base Type: G23 (2-pin single-ended base with one molded snap)
- Lifespan: Approximately 9,000 hours or more under normal usage conditions.
- Compatibility: Works with 110V, 120V, 130V, 220V, 230V, 240V systems.
- Germicidal Efficacy: Delivers at least 16,000 microwatt seconds per square centimeter.
Image 2.1: Two Anyray 5W UV-C Germicidal Ultraviolet Replacement Bulbs. These bulbs feature a clear tubular design with a G23 2-pin base at the bottom.
3. Installation Instructions
- Power Disconnection: Before attempting any installation, ensure the power supply to the fixture is completely disconnected. This is critical for safety.
- Remove Old Bulb (if applicable): If replacing an existing bulb, carefully grasp the base of the old bulb and gently pull it straight out from the socket. Avoid twisting or bending the bulb, as it may break.
- Inspect New Bulb: Carefully unpackage the new Anyray UV-C bulb. Inspect it for any signs of damage, such as cracks or broken pins. Do not use a damaged bulb.
- Insert New Bulb: Align the two pins of the G23 base with the corresponding slots in the fixture's socket. Gently push the bulb straight into the socket until it clicks securely into place. The G23 base has one molded snap to ensure correct orientation. Do not force the bulb.
- Verify Installation: Ensure the bulb is firmly seated in the socket.
- Restore Power: Once the bulb is securely installed and you have confirmed that the fixture is properly assembled and enclosed (to prevent UV-C exposure), restore power to the unit.
Image 3.1: Close-up of two Anyray 5W UV-C Germicidal Ultraviolet Replacement Bulbs, showing the EPA Est. #100578-WA-1 marking on the base of each bulb. This marking indicates the manufacturing establishment registration with the Environmental Protection Agency.
4. Operation
Once installed in a compatible fixture and power is supplied, the Anyray UV-C bulb will begin emitting germicidal ultraviolet light. The bulb is designed for continuous operation within its intended application (e.g., water or air purification). Always ensure the fixture is fully enclosed during operation to prevent UV-C exposure.
The effective lifespan of the bulb is approximately 9,000 hours. After this period, while the bulb may still illuminate, its germicidal effectiveness will significantly decrease. It is recommended to replace the bulb at or before this interval to maintain optimal performance of your purification system.
5. Maintenance and Replacement
The Anyray UV-C bulb itself requires no specific maintenance other than periodic replacement. To ensure continuous and effective germicidal action, replace the bulb after approximately 9,000 hours of operation, or as recommended by your fixture's manufacturer.
When replacing the bulb, follow the safety and installation instructions outlined in Section 1 and Section 3 of this manual.
6. Troubleshooting
- Bulb does not light up:
- Ensure the power supply to the fixture is active.
- Check that the bulb is correctly and securely seated in the G23 socket.
- Inspect the bulb for any visible damage.
- If the fixture uses a ballast, ensure the ballast is functioning correctly.
- If the bulb is old, it may have reached the end of its operational life and requires replacement.
- Bulb lights up but germicidal effectiveness seems low:
- The bulb may have exceeded its effective lifespan (9,000 hours). Even if it still glows, its UV-C output diminishes over time. Replace the bulb.
- Ensure the fixture's quartz sleeve (if applicable) is clean and free of deposits that could block UV-C light.
- Bulb burns out quickly (within days/weeks):
- Verify that the bulb's wattage and voltage rating match the requirements of your fixture. This bulb is 5W and compatible with 110-240V systems.
- Ensure the fixture provides stable power. Fluctuations or incorrect voltage can shorten bulb life.
- Check for proper ventilation within the fixture; excessive heat can reduce bulb lifespan.
- If multiple bulbs fail quickly, there might be an issue with the fixture itself (e.g., faulty ballast or wiring).
7. Specifications
| Feature | Specification |
|---|---|
| Brand | Anyray |
| Model | AUVC-5W |
| Wattage | 5 Watts |
| Bulb Base | G23 (2-pin) |
| Light Color | Ultraviolet (UV-C) |
| Voltage Compatibility | 110V, 120V, 130V, 220V, 230V, 240V |
| Bulb Shape | Tubular (T) |
| Material | Copper (base contacts) |
| Average Lifespan | 9,000+ hours |
| UV-C Dosage | At least 16,000 microwatt seconds per square centimeter |
| EPA Establishment No. | 100578-WA-1 |
| Item Weight | 2.08 ounces (approx.) |
| Package Dimensions | 6.14 x 2.28 x 1.65 inches (approx.) |
8. Warranty and Support
Specific warranty information for this product is not provided in the available documentation. For any questions regarding product performance, installation, or troubleshooting beyond this manual, please contact Anyray customer support through their official channels or the retailer from whom the product was purchased.
Always refer to the instructions provided with your specific UV-C fixture for detailed compatibility and operational guidelines.