ApooDr ASF16-18H2B

ApooDr 18000 BTU Mini Split Air Conditioner Ductless Inverter System User Manual

Model: ASF16-18H2B | Brand: ApooDr

1. Introduction and Product Overview

The ApooDr 18000 BTU Mini Split Air Conditioner with Heat Pump is an advanced, energy-efficient system designed to provide optimal climate control for your space. Featuring inverter technology, it offers both powerful cooling and effective heating, suitable for areas up to 1000 sq ft. This system operates quietly and includes a comprehensive installation kit for convenience. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.

ApooDr 18000 BTU Mini Split Air Conditioner with indoor unit, outdoor unit, and remote control.

Figure 1.1: Complete ApooDr Mini Split Air Conditioner System with indoor unit, outdoor unit, remote, and installation accessories.

2. Package Contents

Upon unpacking, please verify that all components listed below are present and in good condition. If any items are missing or damaged, contact customer support immediately.

  • Indoor Unit
  • Outdoor Unit
  • Backlit LCD Remote Control
  • Pre-flared, Insulated Copper Line Set (approx. 16 FT)
  • Communication Wires
  • Installation Accessories (e.g., drain hose, wall sleeve)
Image showing the indoor unit, outdoor unit, communication wires, pre-flared insulated copper line set, and remote control included in the package.

Figure 2.1: Visual representation of the main components included in your order.

3. Setup and Installation

Professional installation is required for this mini split system to ensure proper function, safety, and warranty validity. Incorrect installation can lead to system malfunction, property damage, or personal injury.

3.1 Pre-Installation Checklist

  • Ensure the installation area meets local building codes and regulations.
  • Verify electrical supply (220V/60Hz) is compatible and sufficient.
  • Confirm proper drainage for condensate.
  • Ensure adequate clearance around both indoor and outdoor units for airflow and maintenance.

3.2 Installation Steps (Overview)

While professional installation is mandatory, a general overview of the process includes:

  1. Mounting the indoor unit on the wall.
  2. Installing the outdoor unit on a stable, level surface.
  3. Connecting the pre-flared copper line set between the indoor and outdoor units.
  4. Connecting electrical wiring and communication cables.
  5. Vacuuming the refrigerant lines to remove air and moisture.
  6. Checking for leaks and performing a test run.

For detailed, step-by-step installation instructions, please refer to the official Installation Manual (PDF).

A person giving a thumbs up next to an installed indoor mini split unit and an outdoor unit, indicating successful installation.

Figure 3.1: Example of a professionally installed ApooDr Mini Split System.

4. Operating Modes

The ApooDr Mini Split system offers five distinct operating modes to ensure your comfort in various conditions. All modes are easily accessible and controllable via the included backlit LCD remote.

4.1 Available Modes

  • Auto Mode: The system automatically selects the appropriate operating mode (Cool, Heat, or Fan) based on the set temperature and current room temperature.
  • Cool Mode: Provides cooling to lower the room temperature. Adjustable from 62℉ (16.7℃) to 90℉ (32.2℃).
  • Dry Mode (Dehumidification): Reduces humidity in the room without significant temperature change.
  • Heat Mode: Provides heating to raise the room temperature. Adjustable from 32℉ (0℃) to 86℉ (30℃).
  • Fan Mode: Circulates air without heating or cooling. Fan speed can be adjusted.

4.2 Remote Control Functions

The backlit LCD remote allows you to:

  • Turn the unit ON/OFF.
  • Select operating modes.
  • Adjust temperature settings.
  • Control fan speed.
  • Set timer functions (Timer ON/OFF).
  • Activate Sleep mode for quiet operation and energy saving.
  • Control oscillation (swing) of the air deflector.
  • Access special features like Turbo, Clean, LED display control, and Follow Me function.
Image showing the indoor unit with air flowing out, indicating both cooling and heating capabilities, and listing the five operating modes: Auto, Cool, Dry, Heat, and Fan.

Figure 4.1: The ApooDr Mini Split system offers 5 versatile operating modes for year-round comfort.

Close-up image of the backlit LCD remote control for the ApooDr Mini Split Air Conditioner, showing various function buttons and the digital display.

Figure 4.2: The intuitive backlit LCD remote control for easy system management.

5. Maintenance

Regular maintenance ensures the longevity and efficient operation of your ApooDr Mini Split system. Always turn off the power to the unit before performing any maintenance.

5.1 Air Filter Cleaning

The indoor unit is equipped with a permanently washable and easy-to-clean air filter. Regular cleaning of the air filter is crucial for maintaining air quality and system efficiency.

  • Frequency: Clean the filter every two weeks or more frequently depending on usage and air quality.
  • Steps:
    1. Open the front panel of the indoor unit.
    2. Gently remove the air filter(s).
    3. Wash the filter(s) with lukewarm water and a mild detergent.
    4. Rinse thoroughly and allow to air dry completely before re-installing. Do not expose to direct sunlight.
    5. Re-install the dry filter(s) and close the front panel.

5.2 Outdoor Unit Maintenance

Periodically inspect the outdoor unit for any obstructions (leaves, debris) around the condenser coils and fan. Gently clear any blockages to ensure proper airflow. Professional cleaning of the outdoor coil may be required annually.

6. Troubleshooting

If you encounter issues with your ApooDr Mini Split system, please refer to the official Troubleshooting Guide (PDF) for detailed solutions. Below are some common issues and general advice:

6.1 Common Issues and Solutions

  • Unit not turning on: Check power supply, circuit breaker, and ensure the remote control batteries are not depleted.
  • Insufficient cooling/heating: Verify correct mode selection and temperature setting. Clean air filters. Ensure no obstructions to airflow. Check for ice on the outdoor unit (in heating mode, during defrost cycle).
  • Unusual noises: Minor noises during operation are normal. Excessive or unusual noises may indicate a problem; consult the troubleshooting guide or a professional.
  • Water leakage from indoor unit: Check the condensate drain line for blockages or improper slope.

If problems persist after consulting the troubleshooting guide, contact a qualified HVAC technician or ApooDr customer support.

7. Specifications

Key technical specifications for the ApooDr 18000 BTU Mini Split Air Conditioner (Model: ASF16-18H2B):

FeatureSpecification
Cooling Capacity18000 BTU
Heating Capacity18000 BTU
SEER2 (Seasonal Energy Efficiency Ratio 2)18.3
HSPF2 (Heating Seasonal Performance Factor 2)8.70
Voltage208/230V / 60Hz
Coverage AreaUp to 1000 sq ft
Noise Level (Indoor)30 dB
Refrigerant TypePre-Charged R-410A
Indoor Working Temperature (Cooling)62℉ ~ 90℉ (16.7℃ ~ 32.2℃)
Indoor Working Temperature (Heating)32℉ ~ 86℉ (0℃ ~ 30℃)
Outdoor Working Temperature (Cooling)5℉ ~ 122℉ (-15℃ ~ 50℃)
Outdoor Working Temperature (Heating)5℉ ~ 86℉ (-15℃ ~ 30℃)
CertificationsAHRI Certified & UL Certified

8. Warranty and Support

8.1 Product Warranty

The ApooDr Mini Split Air Conditioner comes with the following warranty coverage:

  • Compressor: 5-Year Warranty
  • Parts: 2-Year Warranty

Please retain your proof of purchase for warranty claims. The warranty is valid only with professional installation.

8.2 Customer Support

For any questions, technical assistance, or warranty claims, please contact ApooDr customer support. Refer to the contact information provided with your product packaging or visit the official ApooDr website for support details.

Related Documents - ASF16-18H2B

Preview ApooDr ASF16 Series Air Conditioner Owner's and Installation Manual
Comprehensive guide for ApooDr ASF16 series air conditioners, covering owner's information, installation procedures, maintenance, troubleshooting, and specifications. Learn how to safely install and operate your ApooDr air conditioning unit.
Preview ApooDr Split-Type Room Air Conditioner Owner's Manual & Installation Guide
Comprehensive guide for ApooDr split-type room air conditioners, covering safety precautions, unit specifications, features, care and maintenance, troubleshooting, accessories, and detailed installation procedures for both indoor and outdoor units. Includes refrigerant piping connection, air evacuation, electrical checks, and test run instructions.
Preview ApooDr Split Type Air Conditioner Instruction Manual
This instruction manual provides essential information and recommendations for the proper installation, operation, and maintenance of the ApooDr Split Type Air Conditioner to ensure optimal performance and longevity.
Preview ApooDr Ducted Heat Pump Split System Limited Warranty Statement
Official limited warranty statement for ApooDr Ducted Heat Pump Split Systems, detailing coverage, limitations, and product registration requirements.
Preview ApooDr AHU3G-24HFN-AB Series Air Conditioner Dimensions Guide
Detailed dimensional specifications in inches for the ApooDr AHU3G-24HFN-AB series air conditioning units, including indoor and outdoor components. Relevant for models AHU3G-24HFN-AB-50FT, AHU3G-24HFN-AB-25FT, and CAC-24k.
Preview ApooDr AHU 3rd Gen 3D Inverter Series Air Handler Service Manual
Service manual for the ApooDr AHU 3rd Gen 3D Inverter Series Air Handler units, covering installation, operation, troubleshooting, and safety precautions for models AHU3G-24HFN-A through AHU3G-60HFN-A.