ELSIST HOME950

ELSIST HOME950 Uninterruptible Power Supply (UPS) User Manual

Model: HOME950

1. Introduction

This manual provides essential information for the safe and efficient operation of your ELSIST HOME950 Uninterruptible Power Supply (UPS). A UPS is designed to provide emergency power to a load when the input power source or mains power fails. It also provides protection from power surges and voltage fluctuations. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Important Safety Instructions

Please observe the following safety precautions to ensure safe operation and to prevent damage to the UPS or connected equipment.

  • Placement: Install the UPS in a well-ventilated area, away from direct sunlight, heat sources, and excessive dust. Ensure adequate clearance around the unit for proper airflow.
  • Environment: Do not operate the UPS in environments with high humidity or near liquids. Avoid placing the UPS where it could be exposed to water or other fluids.
  • Power Source: Connect the UPS to a grounded AC power outlet. Do not remove the grounding prong from the power cord.
  • Overload: Do not overload the UPS. Ensure the total power consumption of connected devices does not exceed the UPS's rated capacity.
  • Servicing: There are no user-serviceable parts inside the UPS. Refer all servicing to qualified service personnel. Opening the casing may result in electric shock.
  • Battery: The UPS contains a sealed lead-acid battery. Do not dispose of batteries in a fire, as they may explode. Follow local regulations for battery disposal.

3. Package Contents

Verify that all items listed below are included in your package:

  • ELSIST HOME950 UPS Unit
  • User Manual (this document)
  • AC Power Cord

4. Product Overview

4.1 Front Panel

The front panel of the ELSIST HOME950 UPS features indicators and control buttons for easy operation.

ELSIST HOME950 UPS Front View

Image: Front view of the ELSIST HOME950 UPS, showing the power button and LED indicators.

  • Power Button: Press to turn the UPS ON or OFF.
  • LED Indicators: Display the operational status of the UPS (e.g., AC mode, battery mode, fault).

4.2 Rear Panel

The rear panel provides the necessary connections for power input and output.

  • AC Input: Connects the UPS to the mains power supply.
  • Schuko Output (Type F): Provides battery backup and surge-protected power to connected devices. This model features one Schuko Type F connector.

5. Setup

5.1 Placement

Choose a suitable location for your UPS:

  • Place the UPS on a flat, stable surface.
  • Ensure the ambient temperature is between 0°C and 40°C (32°F and 104°F).
  • Maintain relative humidity between 0% and 90% (non-condensing).
  • Keep the UPS away from sources of moisture, heat, and direct sunlight.

5.2 Connecting the UPS

  1. Connect the supplied AC power cord to the AC Input port on the rear of the UPS.
  2. Plug the other end of the AC power cord into a grounded wall outlet.
  3. Connect your computer, monitor, and other critical devices to the Schuko Type F output connector on the rear of the UPS.
  4. Allow the UPS to charge for at least 8 hours before initial use to ensure optimal battery runtime.

6. Operating the UPS

6.1 Powering On/Off

  • To Power On: Press and hold the Power Button on the front panel for approximately 3 seconds until you hear a beep and the indicators light up.
  • To Power Off: Press and hold the Power Button for approximately 3 seconds until the indicators turn off.

6.2 Understanding Indicators

The LED indicators on the front panel provide information about the UPS status:

  • Green LED (Solid): UPS is operating in AC mode, providing power to connected devices and charging the battery.
  • Green LED (Flashing) & Audible Alarm: UPS is operating in battery mode due to a power outage. The alarm indicates the remaining battery capacity is low.
  • Red LED (Solid) & Continuous Alarm: Indicates a fault condition. Refer to the Troubleshooting section.

6.3 Battery Mode

When the mains power fails, the UPS will automatically switch to battery mode, providing power to connected devices. The UPS will emit an audible alarm to indicate it is running on battery power. The duration of battery backup depends on the load connected and the battery's charge level.

7. Maintenance

7.1 Battery Care

  • To maintain optimal battery life, ensure the UPS is connected to an AC outlet at all times to keep the battery charged.
  • Perform a full discharge and recharge cycle every 3-6 months if the UPS is not frequently used or experiences power outages.
  • Battery replacement should only be performed by qualified service personnel.

7.2 Cleaning

To clean the UPS, disconnect it from the power outlet and all connected devices. Use a soft, dry cloth to wipe the exterior. Do not use liquid or aerosol cleaners.

8. Troubleshooting

If you encounter issues with your ELSIST HOME950 UPS, refer to the table below for common problems and solutions.

ProblemPossible CauseSolution
UPS does not turn on.No AC input power. Battery is deeply discharged.Ensure the AC power cord is securely connected to a live wall outlet. Allow the UPS to charge for several hours.
UPS beeps continuously and Red LED is solid.Internal fault or battery failure.Turn off the UPS, disconnect all devices, and unplug from the wall. Wait a few minutes, then plug it back in and try to power on. If the issue persists, contact support.
Short battery backup time.Battery not fully charged. Battery nearing end of life. Overload.Allow the UPS to charge for at least 8 hours. Reduce the number of connected devices. Consider battery replacement if the battery is old.
UPS is in battery mode even with AC power present.Input voltage is too high or too low (AVR activating).This is normal operation for the Automatic Voltage Regulation (AVR) feature. The UPS is protecting your devices from voltage fluctuations.

If the problem persists after trying these solutions, please contact ELSIST customer support.

9. Specifications

Technical specifications for the ELSIST HOME950 UPS:

FeatureSpecification
ModelHOME950
Capacity950 VA / 570 W
Input Voltage220-240 VAC (Nominal)
Output Voltage220-240 VAC (Nominal)
Output Sockets1 x Schuko Type F
Transfer TimeTypically 2-6 ms
Battery TypeSealed Lead-Acid, Maintenance-Free
Recharge Time8 hours to 90% capacity (approx.)
Operating Temperature0°C - 40°C
Operating Humidity0% - 90% (non-condensing)

10. Warranty and Support

ELSIST products are manufactured to high-quality standards and are warranted against defects in materials and workmanship for a specified period from the date of purchase. Please refer to the warranty card included with your product or visit the official ELSIST website for detailed warranty terms and conditions.

For technical support, service, or warranty claims, please contact ELSIST customer service through their official channels. Have your product model and serial number ready when contacting support.

ELSIST Official Website: www.elsist.it (This is a placeholder link, please verify the actual support website)

Related Documents - HOME950

Preview Exenta MT-150 Industrial Touchscreen Monitor Specifications
Detailed specifications for the Exenta MT-150 industrial touchscreen monitor, including display, touch screen, mechanical, environmental, and accessory details. Manufactured by Elsist.
Preview Exenta MT-120 Industrial Monitor - Technical Specifications
Detailed technical specifications for the Exenta MT-120 industrial monitor, covering display, touch screen, mechanical, environmental, and accessory features. Includes dimensions and connectivity.
Preview Exenta MT-100 10.1-inch Industrial Monitor Specifications
Detailed specifications for the Exenta MT-100 10.1-inch industrial monitor by Elsist. Features include a 1280x800 TFT-LCD display, 400 cd/m² brightness, resistive touch panel, VGA/HDMI connectivity, and IP65 front panel rating. Covers display, touch, mechanical, environmental, and accessory details.
Preview Exenta MT-156C Industrial Touchscreen Monitor Specifications
Detailed technical specifications for the Exenta MT-156C industrial touchscreen monitor, including display, touch screen, mechanical, environmental, and accessory details. Features 15.6" TFT-LCD, 1920x1080 resolution, IP65 front panel rating, and VESA mounting options.
Preview Exenta MT-170 Industrial Monitor Specifications and Dimensions
Comprehensive technical specifications and dimensional details for the Exenta MT-170 industrial touchscreen monitor. This document covers display characteristics, touch interface, mechanical specifications, environmental resistance (IP65), and mounting options, making it ideal for industrial applications.