1. Introduction
The EDIKUN FS2P3 is a 3-pedal USB foot switch designed to provide hands-free input for computers. It allows users to program keyboard and mouse operations to each pedal, enhancing efficiency and reducing strain on hands and wrists. This device is compatible with Japanese keyboards and offers both standard and advanced programming options.

Figure 1: EDIKUN FS2P3 3-Pedal USB Foot Switch with USB cable.
2. Setup
2.1 Package Contents
Before proceeding, ensure all components are present:
- EDIKUN FS2P3 3-Pedal USB Foot Switch
- USB Cable (integrated)
- Quick Start Guide (if included)
2.2 Connecting the Device
- Locate an available USB 2.0 (or later) port on your computer.
- Connect the USB cable from the FS2P3 foot switch to the USB port on your computer.
- The device is plug-and-play for basic functionality, but software is required for programming.
2.3 Software Installation
To program the foot switch, dedicated software is required. This software is compatible with Windows XP or above, and Mac operating systems.
- Download the latest programming software from the official Japan Ergonomics Co., Ltd. support page.
- Follow the on-screen instructions to install the software on your computer.
- Launch the software after installation to begin configuration.

Figure 2: Programming software interface showing Standard and Advanced settings.
3. Operating Instructions
3.1 Basic Operation
Once connected and programmed, simply press a pedal with your foot to activate the assigned keyboard or mouse signal. The FS2P3 features a low-profile design and patented technology to ensure quick response and minimize accidental activations.

Figure 3: Ergonomic design for comfortable and precise foot operation.
3.2 Programming Pedals (Standard Settings)
The programming software allows you to assign various functions to each pedal:
- Keyboard Operations: Assign any key, such as Enter, Space, Shift, F-keys, or Ctrl+A.
- Mouse Operations: Assign left-click, right-click, double-click, or scroll functions.
- Japanese Keyboard Compatibility: Register 'half-angle/full-angle key' and 'non-conversion keys'.
To program:
- Open the programming software.
- Select the pedal you wish to configure.
- Choose the desired action from the 'Standard Settings' menu.
- Apply the settings to the foot switch.
3.3 Advanced Settings (Windows Only)
For more complex tasks, the 'Advanced Settings' provide additional customization options:
- Mouse Pointer Movement: Configure and adjust the speed of mouse pointer movement.
- Simultaneous Key Press: Assign multiple keys to be pressed at once.
- Key Macros: Create sequences of key presses.
- Continuous Output: Set a key or action to repeat while the pedal is held down.
Advanced settings can be saved to a file (Windows only) for easy backup or transfer to other foot switches.
4. Maintenance
4.1 Cleaning
To maintain optimal performance and appearance, clean the foot switch periodically:
- Disconnect the device from your computer before cleaning.
- Use a soft, dry cloth to wipe the exterior surfaces.
- For stubborn dirt, a slightly damp cloth with mild soap can be used, followed by a dry cloth.
- Avoid using harsh chemicals, abrasive cleaners, or excessive moisture, as these can damage the device.
4.2 Storage
When not in use, store the foot switch in a clean, dry environment away from direct sunlight and extreme temperatures.
5. Troubleshooting
If you encounter issues with your EDIKUN FS2P3, refer to the following common solutions:
- Device Not Recognized: Ensure the USB cable is securely connected to both the foot switch and the computer. Try a different USB port or a different computer to rule out port issues.
- Pedal Not Responding: Verify that the programming software has successfully applied the settings to the foot switch. Re-program the pedal if necessary.
- Side Button for Mouse Cannot Be Set: This issue can often be resolved by setting the function to 'Alt + Arrow key' within the programming software. Refer to the quick start guide for detailed instructions.
- Software Not Launching/Crashing: Ensure your operating system meets the minimum requirements (Windows XP or above, Mac). Reinstall the software from the official support page.
- Incorrect Output: Double-check the assigned function for the specific pedal in the programming software. Ensure no conflicting software or drivers are interfering.
For further assistance, contact customer support as detailed in the 'Warranty and Support' section.
6. Specifications
| Feature | Detail |
|---|---|
| Model Number | FS2P3 |
| Number of Pedals | 3 |
| Connectivity | USB (Type A, approx. 3m cable) |
| Operating Systems | Windows XP or above, Mac (USB 2.0 or later port required) |
| Actuator Type | Push Button |
| Operation Mode | ON-OFF |
| Switch Type | High-quality Omron® switch |
| Durability | Durable Japanese-made spring, 1 million uses |
| Material | Reinforced plastic (3mm thick cover, multiple ribs) |
| Dimensions (Approx.) | 304.5mm (Width) x 111.6mm (Depth) x 30.0mm (Height, excluding cable) |
| Weight | Approximately 0.28 g (0.01 Ounces) |
| International Protection Rating | IP00 |

Figure 4: Dimensional overview of the foot switch.

Figure 5: Internal view highlighting the Omron switch and durable spring.

Figure 6: Details of the robust cover, non-slip rubber feet, and durable USB cable.
7. Warranty and Support
7.1 Product Warranty
The EDIKUN FS2P3 Foot Switch comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects under normal use. Please retain your proof of purchase for warranty claims.
7.2 Customer Support
For technical support, troubleshooting assistance, or warranty inquiries, please visit the official support page of Japan Ergonomics Co., Ltd. (the manufacturer). The support page provides resources, FAQs, and contact information for further assistance.
Manufacturer: 株式会社エジクン技研 (Japan Ergonomics Co., Ltd.)