1. Introduction
The Beok BOT-313W is a programmable room thermostat designed for controlling water boilers. It features an LCD digital display and operates on two 1.5V AA batteries. The thermostat monitors the ambient room temperature and activates or deactivates the boiler to maintain the desired set temperature, ensuring efficient heating and energy savings.

Image 1.1: Front view of the Beok BOT-313W Thermostat.
2. Safety Information
- Always disconnect power before installation or maintenance to prevent electric shock.
- Installation should be performed by a qualified electrician or heating engineer.
- Do not expose the thermostat to water or excessive humidity.
- Keep out of reach of children.
- Ensure correct battery polarity when inserting batteries.
3. Package Contents
Verify that all items are present in the package:
- Beok BOT-313W Thermostat
- User Manual (Guiding Book)
- 2 Mounting Screws

Image 3.1: Contents included in the Beok BOT-313W package.
4. Product Overview and Display Icons
The thermostat features an LCD display with touch buttons for easy interaction. Understanding the icons is crucial for operation.

Image 4.1: Explanation of icons and display elements.
Key Display Elements:
- Room Temp: Displays the current ambient temperature.
- Set Temp: Displays the desired temperature.
- Time/Day: Shows current time and day of the week.
- Heating On: Indicates when the boiler is active.
- Child Lock: Indicates if the child lock function is active.
- Frost Protection: Indicates if frost protection is active.
5. Installation
5.1 Mounting the Thermostat
The thermostat can be mounted on a wall using two screws. Ensure the mounting location is away from direct sunlight, drafts, or heat sources for accurate temperature readings.

Image 5.1: Thermostat dimensions and wall mounting illustration.
5.2 Wiring Diagram
Follow the wiring diagram carefully. Incorrect wiring can damage the thermostat or the boiler system. Consult a professional if you are unsure.

Image 5.2: Wiring connections for the BOT-313W thermostat.
- Open the thermostat casing using a screwdriver as shown in the diagram.
- Connect the boiler control wires to the designated terminals (COM, NO).
- Ensure all connections are secure before closing the casing.
6. Setup
6.1 Battery Installation
The thermostat requires two 1.5V AA batteries for operation. Open the battery compartment, insert the batteries according to the polarity markings, and close the compartment.
6.2 Initial Power-On
Upon first power-on or after battery replacement, the thermostat will display the current time and temperature. You may need to set the current time and day.
7. Operation
7.1 Setting the Temperature
Use the Up and Down arrow buttons to adjust the desired set temperature. The thermostat will automatically activate the boiler when the room temperature falls below the set temperature and deactivate it when the set temperature is reached.
7.2 Programming (5+1+1 Periods)
The thermostat supports a 5+1+1 programmable schedule, allowing you to set different temperatures for various times of the day across weekdays, Saturday, and Sunday. This optimizes comfort and energy efficiency.

Image 7.1: Example of a 5+1+1 programmable schedule.
- Press the M (Menu) button to enter programming mode.
- Use the Up and Down buttons to navigate through periods and adjust time/temperature settings.
- Confirm each setting by pressing the M button or wait for automatic exit from programming mode.
7.3 Child Lock Function
The child lock feature prevents unauthorized changes to the thermostat settings.

Image 7.2: Child Lock function activated.
To activate/deactivate the child lock, refer to the specific instructions in the guiding book, typically involving a long press of a combination of buttons.
7.4 Other Functions
- Manual Mode: Allows temporary override of the programmed schedule.
- Temperature Calibration: Adjusts the displayed temperature for accuracy.
- Frost Protection: Automatically activates heating if the temperature drops below a set minimum (e.g., 5°C) to prevent pipes from freezing.
- High-Temperature Protection: Prevents the temperature from exceeding a safe limit.
8. Maintenance
- Clean the thermostat's screen and casing with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Replace batteries annually or when the low battery indicator appears on the display.
- Ensure the thermostat's vents (if any) are not obstructed to allow for proper air circulation and accurate temperature sensing.
9. Troubleshooting
If you encounter issues, try the following common solutions:
- No Display: Check battery installation and replace if necessary.
- Incorrect Temperature Reading: Ensure the thermostat is not exposed to direct heat/cold sources or drafts. Calibrate temperature if needed (refer to guiding book).
- Boiler Not Responding: Check wiring connections. Ensure the thermostat is in heating mode and the set temperature is above the ambient temperature.
- Settings Not Saving: Ensure batteries are not critically low.
For persistent issues, contact customer support.
10. Specifications
| Feature | Specification |
|---|---|
| Brand | BEOK CONTROLS |
| Model Number | BOT-313W |
| Power Source | 2 x 1.5V AA Batteries |
| Voltage | 220 Volts (for boiler control circuit) |
| Temperature Accuracy | 0.5 °C |
| Adjustable Temperature Range | 5 °C to 35 °C |
| Display | LCD with Touch Buttons |
| Programmability | 5+1+1 periods |
| Dimensions | 11.1 x 10 x 6.7 cm (Package) |
| Item Weight | 180 g |
| Backlight | Yes |
| UPC | 765117650981 |
11. Warranty and Support
BEOK CONTROLS offers a 100% satisfaction guarantee. If your thermostat does not meet your expectations, please contact customer support for assistance. We are committed to providing products that simplify your life and resolve any issues promptly.
For support, refer to the contact information provided in your product packaging or on the official BEOK CONTROLS website.