1. Product Overview

The Kamoer KCM-ODM is a compact stepper peristaltic pump designed for precise liquid dosing applications. It features a 12V/24V power input, adjustable flow rate from 10 to 452 mL/min, and comes equipped with a driver board (2802 Controller) for direct use. The pump utilizes Pharmed BPT tubing (4.8mm ID × 8.0mm OD) and a 3-rotor design for consistent performance. Its integrated controls allow for easy adjustment of flow speed and direction.

Kamoer KCM-ODM Peristaltic Pump

Image 1: Kamoer KCM-ODM Stepper Peristaltic Pump with integrated driver board.

2. Specifications

FeatureDetail
VoltageDC 12V/24V
Flow Rate10~452 mL/min
Tubing MaterialPharmed BPT (4.8mm ID × 8.0mm OD)
Working Temperature0~40℃
Relative Humidity<80%
Rotor Type3 rotors
Driver BoardIntegrated 2802 Controller
Pump Head MaterialSilicone (food-grade)
Dimensions (Package)7.09 x 4.92 x 4.69 inches
Weight (Package)1.92 Pounds
Peristaltic pump head with 3 rotors and BPT tubing

Image 2: Close-up view of the 3-rotor pump head and BPT tubing.

3. Setup and Installation

The KCM-ODM pump comes pre-assembled with its driver board, simplifying installation. Ensure the pump is placed on a stable, level surface in an environment within the specified working temperature and humidity ranges.

3.1 Electrical Connection

Connect the pump to a DC 12V or 24V power source. The integrated 2802 Controller is designed for direct wiring. Refer to the wiring diagram for proper connections.

Kamoer KCM-ODM Controller and Driver Wiring Diagram

Image 3: Wiring diagram for the KCM-ODM controller and driver.

Note on Resistors:

  • For 5V interface voltage: No resistor needed; connect directly.
  • For 12V interface voltage: Connect a 1K resistor in series.
  • For 24V interface voltage: Connect a 2.7K resistor in series.

3.2 Tubing Connection

Connect the inlet and outlet tubing to your liquid source and destination. Ensure all connections are secure to prevent leaks. The pump uses threaded joints for reliable connections.

Threaded joint for Kamoer peristaltic pump tubing

Image 4: Detail of the threaded joint for tubing connection.

4. Operation

The KCM-ODM pump features intuitive controls for easy operation.

Kamoer KCM-ODM pump controls: Start/Stop, Flow Direction, Speed Knob, LED Display

Image 5: KCM-ODM pump with labeled control buttons and speed knob.

  1. Start/Stop: Use the green button to start or stop the pump.
  2. Flow Direction: Use the red button to change the direction of liquid flow. This operation should be performed when the pump is paused.
  3. Speed Adjustment: Rotate the black knob to adjust the flow speed. The current speed setting will be displayed on the integrated LED digital display.

Always monitor the liquid flow and adjust the speed as needed for your specific application. Ensure the tubing is properly primed before starting operation to avoid airlocks.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your Kamoer KCM-ODM pump.

  • Tubing Replacement: Peristaltic pump tubing is a wear-and-tear component. Regularly inspect the tubing for signs of wear, cracks, or degradation. Replace the tubing as necessary to maintain accurate flow rates and prevent leaks. The lifespan of the tubing depends on the pumped liquid, operating pressure, and frequency of use.
  • Cleaning: If pumping corrosive or viscous liquids, flush the tubing with an appropriate cleaning solution or distilled water after use. Ensure the exterior of the pump and control board are kept clean and dry.
  • Storage: When not in use for extended periods, disconnect the power and store the pump in a clean, dry environment away from direct sunlight and extreme temperatures.

6. Troubleshooting

This section addresses common issues you might encounter with your KCM-ODM pump.

ProblemPossible CauseSolution
Pump does not startNo power, incorrect wiring, faulty power adapter.Check power connection and adapter. Verify wiring according to the diagram (Image 3).
No liquid flow or inconsistent flowTubing kinked or blocked, air in tubing, worn tubing, incorrect speed setting.Inspect tubing for obstructions. Prime the tubing to remove air. Replace worn tubing. Adjust speed using the black knob.
Speed adjustment knob is stiff or stuckMechanical obstruction, internal issue.Ensure no external debris is obstructing the knob. If the issue persists, contact support.
Pump is noisyImproper mounting, worn components, foreign object.Ensure pump is securely mounted. Inspect for any loose parts or foreign objects. If noise is excessive, contact support.

7. Applications

The Kamoer KCM-ODM peristaltic pump is suitable for a variety of applications requiring precise and controlled liquid transfer, including:

  • Filling and packaging systems
  • Laboratory experiments and research
  • Chemical dosing in industrial processes
  • Food and beverage dispensing
  • Medical and pharmaceutical applications (e.g., secretion analysis, blood cell analysis)
  • Environmental monitoring (e.g., water quality sampling)
Various applications of Kamoer peristaltic pumps in laboratory and industrial settings

Image 6: Examples of Kamoer peristaltic pump applications.

8. Warranty and Support

For warranty information or technical support, please contact Kamoer Fluid Tech (Shanghai) Co., Ltd. or your authorized distributor. Keep your purchase receipt for warranty claims.

Certifications for Kamoer products including ISO, EC Declaration of Conformity, and RoHS

Image 7: Product certifications.

© 2023 K KAMOER. All rights reserved.

Related Documents - KCM-ODM

Preview KCP-KK300-D Adjustable Peristaltic Pump User Manual
User manual for the Kamoer KCP-KK300-D adjustable peristaltic pump, detailing its features, specifications, operating conditions, interface description, and safety precautions.
Preview Kamoer KAS Micro Peristaltic Pump Product Manual | Technical Specifications & Applications
Comprehensive product manual for the Kamoer KAS Micro Peristaltic Pump. Details technical specifications, performance characteristics, typical applications, and adapter hose information. Includes model definitions and flow rate curves.
Preview Kamoer UIP WIFI E Smart Peristaltic Pump User Manual
Comprehensive user manual for the Kamoer UIP WIFI E Smart Peristaltic Pump, detailing its features, operation modes (Continuity, Ration, Remote), system settings, maintenance, and technical specifications.
Preview Kamoer KDS Peristaltic Pump Product Manual - Model KDS-3 Rotor
Comprehensive product manual for the Kamoer KDS peristaltic pump, model KDS-3 Rotor, detailing specifications, performance, applications, and technical parameters for DC brush, synchronous, and stepper motor variants.
Preview Kamoer KDS3000 Peristaltic Pump Product Manual | Specifications & Applications
Comprehensive product manual for the Kamoer KDS3000 Peristaltic Pump, detailing specifications, dimensions, motor options, applications, certifications, and accessories.
Preview Kamoer UIP WIFI E Smart Peristaltic Pump: Quick Start Guide and Technical Specifications
Quick start guide and technical specifications for the Kamoer UIP WIFI E Smart Peristaltic Pump, detailing its features, interface, app connectivity, and warranty information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.