1. Introduction and Overview

This instruction manual provides comprehensive guidance for the safe and effective use of the UPSBatteryCenter® BR900G-FR compatible replacement battery pack. Designed specifically for the APC Back-UPS Pro 900VA (model BR900G-FR), this battery pack ensures your uninterruptible power supply operates reliably, providing critical backup power.

Key features of this replacement battery pack include:

  • 100% Compatible with APC Back-UPS Pro 900VA BR900G-FR.
  • Brand new, fresh stock for optimal performance.
  • Plug & Play Installation, allowing for hot-swapping without downtime.
  • Sealed, Non-Spillable Lead Acid Battery (SLA) technology.

2. Safety Information

Please read and understand all safety warnings before handling or installing the battery pack. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Do not short circuit battery terminals: This can cause severe burns or fire.
  • Do not disassemble or drop the battery: Internal components may be hazardous.
  • Discontinue charging if battery becomes hot: An overheated battery indicates a potential issue.
  • Do not expose to flame or spark: Batteries can explode if exposed to high heat or ignition sources.
  • Keep out of reach of children: Batteries contain corrosive materials.
  • In case of physical contact with liquid: Immediately flush the affected area with water. Seek medical attention if irritation persists.
  • Proper Disposal: This battery is a sealed, non-spillable lead-acid battery and must be recycled. Do not dispose of in household waste. Contact your local recycling center for proper disposal instructions.

3. Setup and Installation

The UPSBatteryCenter® BR900G-FR replacement battery pack is designed for easy, plug-and-play installation. It is hot-swappable, meaning you can replace the battery without shutting down your APC Back-UPS Pro 900VA unit, ensuring no downtime.

Installation Steps:

  1. Locate the battery compartment on your APC Back-UPS Pro 900VA unit. Refer to your UPS manual if unsure.
  2. Carefully remove the old battery pack. The battery pack features tabs for easy disconnection.
  3. To Disconnect Battery: Lift the tabs and pull the battery pack out.
  4. Side view of the UPSBatteryCenter BR900G-FR replacement battery pack showing the 'TO DISCONNECT BATTERY LIFT TABS AND PULL' instructions on red labels.

    Image 3.1: Side view of the battery pack illustrating the disconnect tabs.

  5. To Connect Battery: Orient the new UPSBatteryCenter® BR900G-FR battery pack correctly. The top of the battery pack clearly indicates "INSERT THIS WAY TO CONNECT BATTERY".
  6. Top view of the UPSBatteryCenter BR900G-FR replacement battery pack with blue labels indicating 'INSERT THIS WAY TO CONNECT BATTERY' and safety warnings.

    Image 3.2: Top view of the battery pack showing the correct insertion orientation and safety warnings.

  7. Slide the new battery pack into the compartment until it is fully seated and connected.
  8. Close the battery compartment cover.
  9. Allow the UPS to charge the new battery pack fully before relying on it for extended backup.

4. Operating Instructions

Once installed, the UPSBatteryCenter® BR900G-FR replacement battery pack operates seamlessly with your APC Back-UPS Pro 900VA unit. The UPS will automatically manage the charging and discharging of the battery.

  • Ensure your APC Back-UPS Pro 900VA is connected to a stable power source to allow the battery to charge.
  • Monitor the UPS's display or software for battery status and charge level.
  • The battery will automatically provide power to connected devices during a power outage or fluctuation.

5. Maintenance

To maximize the lifespan and performance of your UPSBatteryCenter® replacement battery pack, consider the following maintenance tips:

  • Temperature: Operate the UPS and battery in a cool, dry environment. Extreme temperatures (hot or cold) can reduce battery life.
  • Charging: Keep the UPS connected to power to ensure the battery remains fully charged. Frequent deep discharges without full recharges can shorten battery life.
  • Regular Checks: Periodically check the battery pack for any signs of physical damage or swelling. If any issues are observed, discontinue use and contact support.
  • Cleaning: Keep the battery compartment and terminals clean and free of dust.

6. Troubleshooting

If you encounter issues with your replacement battery pack, consider the following common troubleshooting steps:

  • UPS Not Recognizing Battery:
    • Ensure the battery pack is fully and correctly inserted into the UPS compartment.
    • Verify that the battery pack is indeed compatible with your specific APC Back-UPS Pro 900VA model (BR900G-FR).
    • Try restarting the UPS unit.
  • Battery Not Holding Charge / Short Runtime:
    • Confirm the UPS is connected to a working power outlet.
    • Allow sufficient time for the battery to charge fully (typically 24 hours after installation).
    • Ensure the ambient temperature is within the recommended operating range.
    • If the battery is old, its capacity may have naturally degraded.
  • Battery Overheating:
    • Immediately disconnect the battery and UPS from power.
    • Do not attempt to use the battery if it feels excessively hot. Contact support.

If these steps do not resolve the issue, please refer to the Warranty and Support section for further assistance.

7. Specifications

AttributeValue
Model NameBR900G-FR
BrandUPS Battery Center
ManufacturerUPSBatteryCenterLtd.
Battery TypeSealed Lead Acid (SLA)
Voltage12V
Capacity7Ah (Ampere-hour)
ReusabilityRechargeable
Compatible UPS ModelAPC Back-UPS Pro 900VA (BR900G-FR)

8. Warranty and Support

Your UPSBatteryCenter® BR900G-FR replacement battery pack comes with a 1-Year Warranty from the date of purchase, covering manufacturing defects.

For technical support, warranty claims, or recycling inquiries, please contact UPSBatteryCenter® directly:

Please have your product model number (BR900G-FR) and purchase details ready when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.