FSTW 1

FSTW IP68 Waterproof Outdoor Biometric Fingerprint RFID Access Control Keypad System User Manual

1. Introduction

This manual provides comprehensive instructions for the FSTW IP68 Waterproof Outdoor Biometric Fingerprint RFID Access Control Keypad System. This system is designed for secure access management, offering multiple identification methods including fingerprint, RFID card, and password. It is suitable for outdoor installation due to its IP68 waterproof rating.

2. Product Components

The FSTW Access Control System package includes the following items:

  • 1x RFID Access Control Keypad
  • 1x Power Supply Unit
  • 1x Door Exit Button
  • 10x RFID Keyfobs (13.56 MHz)
  • 2x Management Cards

Note: Electric locks are not included in this package and must be purchased separately.

3. Specifications

3.1 Access Control Keypad

  • Material: High-quality ABS plastic
  • Operating Voltage: 12V DC
  • Panel: Touch screen panel
  • Waterproof Level: IP68 (suitable for outdoor installation)
  • Working Frequency: 13.56 MHz
  • User Capacity: 120 Fingerprints, 120 Cards, 1 Public Password
  • Card Type: Supports MF 1K card
  • Card Reading Distance: 0-5 cm
  • Identification Methods: Fingerprint, Card, Password
  • Backlight: Blue backlight
  • Doorbell Button: Supports wired doorbell
  • Wiegand Signal: WG26 / 34 input / output
  • Management Card Support: Yes
  • Operating Current: ≤ 30mA
  • Door Opening Time: 0-255 seconds (adjustable)
  • Operating Temperature: -20 °C ~ 70 °C
  • Operating Humidity: 20% ~ 90%
  • Product Size: 140 x 70 x 16 mm

3.2 Power Supply Unit

  • Material: Steel
  • AC Input: Standard AC100V-260V / 50-60HZ
  • DC Output: DC12V / 3A
  • Time Delay: 0-15 seconds (adjustable)
  • Dimension: 140 x 67 x 33 mm (L/W/H)

3.3 Door Exit Button

  • Material: Hard Plastic
  • Maximum Power Rating: 36V DC 3A - 5A output
  • Support: NC Mode (Fail Safe) and NO Mode (Fail Secure)
  • Dimension: 86 x 86 mm (L/W)

3.4 RFID Keyfobs

  • Material: ABS
  • Operating Frequency: 13.56 MHz
  • Chip: MF-1K (does not support EM4100 smart card)
  • Detection Range: 0-5 cm
  • Quantity: 10 pieces

4. Setup and Installation

The FSTW Access Control System operates on a DC12V system and requires professional wiring for proper installation. Ensure all connections are secure and follow local electrical codes.

4.1 Wiring Diagram

Refer to the following diagram for connecting the access controller, power supply, and exit button. Proper wiring is crucial for system functionality and safety.

Wiring Diagram for FSTW Access Control System
Figure 1: Wiring Diagram for FSTW Access Control System. This diagram illustrates the connections between the access controller, power supply, and door exit button, showing input/output terminals and power lines.

4.2 Keypad Dimensions

Before installation, ensure adequate space and proper mounting for the access control keypad. The dimensions are provided below.

Dimensions of FSTW Access Control Keypad
Figure 2: Dimensions of FSTW Access Control Keypad. The image shows the front, side, and back views of the keypad with measurements: 140mm height, 70mm width, 16mm depth, and mounting hole distances.

4.3 Power Supply Unit

The power supply unit converts AC input to DC12V for the system. It also allows for adjustment of the door opening time delay.

FSTW Power Supply Control Unit (AC110-260V to DC12V 3A)
Figure 3: FSTW Power Supply Control Unit. This image displays the power supply unit with its input/output specifications (AC110-260V to DC12V 3A) and adjustable time delay feature.

4.4 Exit Button and Keyfobs

The door exit button provides a convenient way to exit the secured area. The RFID keyfobs are used for card-based access.

Door Exit Button and 10 RFID Keyfobs (13.56MHz MF-1K)
Figure 4: Door Exit Button and RFID Keyfobs. This image shows the physical door exit button with its dimensions and a set of 10 blue RFID keyfobs, specifying their 13.56MHz MF-1K chip type.

5. Operating Instructions

The FSTW Access Control System offers multiple ways to gain access. The keypad features a touch interface, a doorbell button, and a fingerprint collector.

FSTW Access Control Keypad with Touch Key-press, Doorbell Button, and Fingerprint Collector
Figure 5: FSTW Access Control Keypad Features. This image highlights the touch key-press area, the doorbell button, and the fingerprint collector on the keypad.

5.1 Access Methods

  • Fingerprint: Place your registered finger on the fingerprint collector.
  • RFID Card: Present a registered RFID keyfob or card within 0-5 cm of the keypad.
  • Password: Enter your registered password using the touch keypad.

5.2 Doorbell Function

Press the doorbell button on the keypad to activate a connected wired doorbell.

5.3 Exit Button

To exit the secured area, press the door exit button. This button is typically installed on the inside of the door.

FSTW Access Control System Installed with Door and RFID Key Card
Figure 6: FSTW Access Control System in Use. This image shows the access controller and exit button installed on a door, with an RFID key card being used for access.

6. Programming

The FSTW Access Control System allows for full programming directly on the keypad, eliminating the need for external software. The included management cards simplify the programming process for users, fingerprints, and passwords.

6.1 User Management

The system supports up to 120 fingerprints, 120 RFID cards, and one public password. Refer to the detailed programming instructions provided with the product for adding, deleting, or modifying user credentials using the management cards.

7. Maintenance

To ensure the longevity and optimal performance of your FSTW Access Control System, follow these maintenance guidelines:

  • Cleaning: Regularly wipe the keypad surface with a soft, damp cloth. Avoid abrasive cleaners or solvents that could damage the touch panel or fingerprint collector.
  • Connection Checks: Periodically inspect all wiring connections to ensure they are secure and free from corrosion, especially for outdoor installations.
  • Environmental Protection: Although IP68 rated, avoid direct, prolonged exposure to extreme weather conditions if possible to extend product life.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates that may improve performance or add features.

8. Troubleshooting

If you encounter issues with your FSTW Access Control System, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Door opens randomlyUnstable power supply, wiring interference, faulty sensor.Check power supply stability. Verify all wiring connections are correct and shielded. Inspect the keypad for damage.
RFID card or fingerprint not recognizedCard/fingerprint not registered, dirty sensor, incorrect placement.Ensure the card/fingerprint is properly enrolled. Clean the fingerprint collector. Present the RFID card correctly within the reading range.
Keypad is unresponsiveNo power, loose connection, internal fault.Check the power supply unit and its connections. Ensure the DC12V output is correct. If the issue persists, contact technical support.
Door does not lock/unlockIncorrect lock wiring, faulty lock, power supply issue.Verify the electric lock wiring (NC/NO mode). Test the electric lock independently. Check the power supply output to the lock.

If these troubleshooting steps do not resolve the issue, please contact FSTW customer support for further assistance.

9. Safety Information

Please read and understand all safety instructions before installing and operating the FSTW Access Control System.

  • Electrical Safety: Installation should be performed by qualified personnel to prevent electrical shock or damage to the system. Disconnect power before performing any wiring or maintenance.
  • Outdoor Installation: While the keypad is IP68 waterproof, ensure all wiring connections are properly sealed and protected from moisture to prevent short circuits.
  • Component Handling: Handle all components with care. Avoid dropping or subjecting them to strong impacts.
  • Intended Use: Use this product only for its intended purpose of access control. Do not modify the system or use it for unauthorized applications.

10. Contact and Support

For technical support, warranty information, or further inquiries regarding your FSTW Access Control System, please refer to the contact details provided with your purchase or visit the official FSTW website.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.