MEDCOS PZ-IO

EZ-IO Compatible IO Needle Trainer User Manual

Model: PZ-IO | Brand: MEDCOS

Introduction

This manual provides comprehensive instructions for the proper use, setup, and maintenance of the MEDCOS EZ-IO Compatible IO Needle Trainer. This device is designed exclusively for medical instructors to facilitate teaching vascular access device skills. It is not intended for patient use.

Product Components

The MEDCOS EZ-IO Compatible IO Needle Trainer set includes the following items:

  • One (1) EZ-IO 25mm 15-Gauge Trainer Intraosseous Needle Set
  • One (1) EZ-Connect Extension Set
  • One (1) EZ-IO Wristband (for training purposes)
  • One (1) NeedleVise 1-Port Sharps Block by Teleflex Arrow
MEDCOS EZ-IO Compatible IO Needle Trainer components

Image: All components included in the MEDCOS EZ-IO Compatible IO Needle Trainer kit. Shown are the trainer needle, extension set, sharps block, and a wristband.

Setup Instructions

Before beginning any training session, ensure all components are present and in good condition. This trainer is designed to be used with a compatible trainer drill (sold separately).

  1. Prepare the Training Site: Secure your anatomical training model (e.g., bone replica) on a stable surface.
  2. Attach the Needle to the Drill: Carefully insert the EZ-IO 25mm 15-Gauge Trainer Intraosseous Needle into the chuck of your compatible trainer drill. Ensure it is securely fastened.
  3. Trainer needle attached to a drill and inserted into a training bone

    Image: A black MEDCOS trainer drill with the red and clear trainer needle attached, demonstrating insertion into a beige bone training model.

Operating Instructions

Follow these steps for effective training simulations:

  1. Simulated Insertion: With the needle attached to the drill, position the needle tip at the desired insertion site on the training model. Activate the drill to simulate the intraosseous insertion process.
  2. Remove Drill: Once the simulated insertion is complete, carefully detach the trainer drill from the needle. The needle should remain in the training model.
  3. Hand detaching the drill from the trainer needle

    Image: A gloved hand carefully detaching the black MEDCOS trainer drill from the red and clear trainer needle, which remains embedded in the training bone.

  4. Remove Needle Stylet: Remove the stylet from the trainer needle, simulating the preparation for fluid administration.
  5. Hand removing the stylet from the trainer needle

    Image: A gloved hand removing the blue stylet from the clear and red trainer needle, which is still inserted into the training bone.

  6. Connect Extension Set: Attach the EZ-Connect Extension Set to the hub of the trainer needle. This simulates connecting the line for fluid or medication delivery.
  7. Connecting the EZ-Connect Extension Set to the trainer needle

    Image: A gloved hand connecting the clear EZ-Connect Extension Set to the red and clear trainer needle, which is inserted into the training bone.

  8. Simulated Fluid Administration: Practice connecting and securing simulated fluid lines to the extension set.
  9. Needle Removal: After the training scenario, carefully remove the trainer needle from the training model.
  10. Sharps Disposal: Dispose of the trainer needle in the NeedleVise 1-Port Sharps Block provided, or an appropriate sharps container, even though it is for training purposes only.

Maintenance and Storage

Proper maintenance ensures the longevity and effectiveness of your trainer components.

  • Cleaning: After each use, wipe down the reusable components (e.g., extension set, sharps block) with a damp cloth and mild disinfectant. Ensure they are completely dry before storage.
  • Inspection: Regularly inspect the trainer needle and extension set for any signs of wear, damage, or degradation. Replace components as necessary.
  • Storage: Store all components in a clean, dry place away from direct sunlight and extreme temperatures. Keep out of reach of children.

Troubleshooting

This section addresses common issues that may arise during the use of the trainer.

ProblemPossible CauseSolution
Needle not securely attaching to drill.Drill chuck not tightened sufficiently; incompatible drill.Ensure the drill chuck is fully tightened. Verify drill compatibility with the trainer needle.
Difficulty inserting needle into training model.Incorrect angle; worn training model; dull trainer needle.Adjust insertion angle. Consider replacing the training model or the trainer needle if excessively worn.
Extension set not connecting properly.Misalignment; damaged connector.Ensure proper alignment before pushing and twisting. Inspect connectors for damage and replace if necessary.

Specifications

AttributeDetail
Model NumberPZ-IO
Needle Gauge15-Gauge
Needle Length25mm
ManufacturerMEDCOS
Item Weight2.08 ounces
Package Dimensions4.84 x 3.66 x 0.83 inches
ASINB08TB7SCMW
Date First AvailableJanuary 19, 2021

Warranty and Support

MEDCOS stands behind its products. If you encounter any defects with your trainer needle(s), replacements may be offered. For support or warranty inquiries, please contact the seller directly through the platform where the product was purchased.

Seller: ULTRALIGHT/MEDCOS

© 2024 MEDCOS. All rights reserved. This manual is for informational purposes only.