1. Introduction

This manual provides detailed instructions for the safe and efficient installation, operation, and maintenance of your Dornbracht 3586097090 Wall-Mounted Single-Lever Mixer. Please read this manual thoroughly before beginning installation or use to ensure proper function and longevity of the product.

2. Safety Information

  • Always turn off the main water supply before beginning any installation or maintenance work.
  • It is recommended that installation be performed by a qualified professional to ensure compliance with local plumbing codes and standards.
  • Use appropriate tools and personal protective equipment during installation.
  • Ensure all connections are securely tightened to prevent leaks.
  • This product is made of lead-free brass, ensuring safe water contact.

3. Package Contents

Verify that all components are present before beginning installation:

  • Pre-assembly kit (main mixer unit)
  • Mounting bracket
  • Water protection sleeve
  • Sound insulation block (100 mm thick)
  • Screws and wall plugs for mounting
  • Sealing material
  • Instruction manual
Dornbracht 3586097090 pre-assembly kit with mounting hardware

Figure 1: Overview of the Dornbracht 3586097090 pre-assembly kit, including the main mixer unit, mounting bracket, water protection sleeve, sound insulation block, screws, wall plugs, and sealing material.

4. Setup and Installation

The Dornbracht 3586097090 mixer is designed for wall-mounted installation. Adhere to the specified installation depths for optimal performance.

4.1. Pre-Installation Checks

  • Ensure the wall structure can support the weight of the mixer and associated plumbing.
  • Confirm water supply lines (cold and hot) are accessible and correctly positioned.
  • Verify the required installation depth: minimum 80 mm, maximum 95 mm.
  • If using an xGRID mounting rail, an additional 10 mm installation depth may be required.

4.2. Installation Steps

  1. Prepare Wall Opening: Create an opening in the wall according to the dimensions specified in the product's technical drawings (not provided in this manual, refer to manufacturer's specifications).
  2. Mount Pre-assembly Kit: Position the pre-assembly kit within the wall opening. Use the provided mounting bracket, screws, and wall plugs to securely fasten the unit to the wall. Ensure the unit is level and at the correct installation depth (between 80 mm and 95 mm).
  3. Connect Water Supply: Connect the 1/2" cold and hot water supply lines (DN 15) to the designated inlets on the mixer unit. Use appropriate sealing material to ensure watertight connections.
  4. Connect Outlets: Connect the 1/2" IG outlet for the wall outlet and the 1/2" IG main outlet to their respective plumbing lines.
  5. Install Protection Components: Place the water protection sleeve and the 100 mm thick sound insulation block around the mixer unit. These components help protect the unit and reduce noise transmission.
  6. Leak Test: Once all connections are made and secured, slowly turn on the main water supply and carefully check all connections for any signs of leaks. Address any leaks immediately before proceeding.
  7. Final Wall Closure: After successful leak testing, the wall can be closed and finished according to standard construction practices.

5. Operation

The Dornbracht 3586097090 is a single-lever mixer, providing intuitive control over water flow and temperature.

  • Water Flow Control: Lift the lever upwards to increase water flow. Push the lever downwards to decrease or stop the water flow.
  • Temperature Control: Move the lever to the left for hot water and to the right for cold water. Adjust the lever position between left and right to achieve the desired water temperature.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your mixer.

  • Cleaning: Clean the visible parts of the mixer regularly with a soft cloth and a mild, non-abrasive cleaning agent. Avoid using harsh chemicals, abrasive sponges, or acidic cleaners, as these can damage the brass finish.
  • Aerator Maintenance: If water flow becomes weak or uneven, the aerator (if applicable to the final trim) may be clogged. Unscrew the aerator, clean it of any debris or mineral deposits, and reattach it.
  • Leak Checks: Periodically inspect the area around the mixer for any signs of water leaks. Address any leaks promptly to prevent water damage.

7. Troubleshooting

Below are common issues and their potential solutions:

ProblemPossible CauseSolution
Low Water FlowClogged aerator; partially closed stopcock; low water pressure.Clean or replace aerator; ensure stopcocks are fully open; check main water pressure.
Water Leaks from ConnectionsLoose connections; worn seals.Tighten connections; replace seals or O-rings.
Inconsistent Water TemperatureFaulty mixer cartridge; issues with hot/cold water supply.Contact a qualified plumber to inspect or replace the cartridge; check hot water heater settings.

If the problem persists after attempting these solutions, please contact a qualified plumber or Dornbracht customer service.

8. Specifications

FeatureDetail
ManufacturerDornbracht
Model Number3586097090
Product Dimensions (L x W x H)22.5 x 22.5 x 21.5 cm
Weight1.63 Kilograms
MaterialBrass
FinishBrass
Installation MethodWall-mounted
Number of Handles1
Handle MaterialBrass
Special FeatureLead-free
Minimum Installation Depth80 mm
Maximum Installation Depth95 mm
Connections2x 1/2" (cold/hot) DN 15
Outlets1x 1/2" IG for wall outlet, 1x 1/2" IG main outlet
Sound Insulation100 mm thick block included
CompatibilityxGRID (with mounting rail, +10 mm depth)

9. Warranty and Support

Information regarding specific warranty terms and spare parts availability for the Dornbracht 3586097090 Wall-Mounted Single-Lever Mixer is not provided in the product details. For detailed warranty information, technical support, or to inquire about spare parts, please contact Dornbracht customer service directly or consult your authorized retailer.