1. Introduction and Overview
This manual provides essential instructions for the safe installation, operation, and maintenance of your Airand LED Ceiling Light Fixture, Model A6005. This 12.8-inch square, 24W LED light delivers 2050 lumens of 5000K daylight white illumination. Designed for flush mounting, it features an IP44 waterproof rating, making it suitable for various indoor environments including bathrooms, kitchens, hallways, bedrooms, and living rooms.

Image 1.1: Airand 12.8-inch Square LED Ceiling Light Fixture (Model A6005)
This image displays the Airand 12.8-inch square LED ceiling light fixture, showcasing its sleek, low-profile design suitable for modern interiors.
Key Features:
- Reliable & Safety: Overload and short-circuit protection to prevent electrical hazards.
- Easy Installation: Built-in LED chips, no incandescent bulbs needed. Designed for quick installation.
- Energy Savings: 24W LED equivalent to a 180W fluorescent tube, saving up to 85% electricity.
- Wide Application: IP44 waterproof rating for use in kitchens, bathrooms, hallways, bedrooms, basements, and more.
- Eye Protection: Milk white plastic housing and qualified LED chips reduce harsh glare and flickering.

Image 1.2: Versatile Application Examples
This image demonstrates the light fixture installed in various rooms including a living room, kitchen, dining room, and corridor, highlighting its adaptability.
2. Safety Information
Please read all safety instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or other hazards.
- Always turn off the power at the circuit breaker before installing, cleaning, or servicing the fixture.
- Ensure the voltage supply matches the fixture's requirements (120 Volts).
- All wiring connections must be in accordance with local and national electrical codes. If you are unsure about wiring, consult a qualified electrician.
- Do not attempt to modify the fixture. Any modifications may void the warranty and create safety risks.
- This fixture is rated IP44 for water resistance, suitable for damp locations, but not for direct water immersion.
- Keep packaging materials away from children.
3. Package Contents
Verify that all components are present and undamaged before proceeding with installation.

Image 3.1: Package Contents and Installation Overview
This image illustrates the items included in the package and a visual summary of the installation process.
- 1x Airand LED Ceiling Light Fixture (Integrated LED)
- 1x Instruction Manual
- 1x Mounting Bracket
- 1x Wiring Port (Connector)
- 4x Screws
- 4x Expansion Screws
- 2x Wiring Caps (Wire Nuts)
4. Specifications
| Feature | Detail |
|---|---|
| Brand | Airand |
| Model | A6005 |
| Product Dimensions | 12.8"L x 12.8"W x 1.9"H |
| Wattage | 24W |
| Brightness | 2050 Lumens |
| Color Temperature | 5000K (Daylight White) |
| Voltage | 120 Volts |
| Material | Plastic |
| Water Resistance Level | IP44 (Water Resistant) |
| Light Source Type | LED (Integrated) |
| Control Method | Wall Switch |
| CRI (Color Rendering Index) | 90.00 |
| Lifespan | 30,000 hours |
| Installation Type | Flush Mount |
| Certification | FCC |

Image 4.1: Product Dimensions and Key Features
This image shows the side profile of the light fixture with its dimensions (1.89 inches / 4.8 cm thickness, 12.8 inches / 32.5 cm width) and highlights features like Non-Dimmable, Super Bright, A++ Energy Star, 180° Beam Angle, No Flickering, and Eye Protection.

Image 4.2: High Color Rendering Index (CRI)
This image demonstrates the high CRI (Color Rendering Index) of 80+, showing how the light renders colors more vividly and naturally compared to lower CRI lights.
5. Installation Instructions
Follow these steps carefully to install your Airand LED Ceiling Light Fixture. Ensure the power is OFF at the circuit breaker before beginning.
- Turn Off Power: Locate the circuit breaker controlling the light fixture's circuit and turn it OFF. Verify power is off using a voltage tester.
- Remove Mounting Bracket: Pull the bracket lock outward from the light fixture and detach the mounting bracket.
- Fix Mounting Bracket: Use the provided screws and expansion screws to securely fix the mounting bracket to the ceiling or wall.
- Wire Connections:
- Option 1 (Using Wiring Port): Pull up the orange buttons on the wiring port to 90°. Insert the live (L) and neutral (N) wires from your ceiling into the corresponding ports. Push down the orange buttons to lock the wires securely.
- Option 2 (Using Wiring Caps): If preferred, use the provided wiring caps to connect the live and neutral wires from your ceiling to the corresponding wires on the light fixture. Ensure connections are tight and insulated.
- Mount Light Fixture: Align the light fixture with the installed mounting bracket and push it into place until it clicks securely.
- Restore Power: Turn the power back ON at the circuit breaker. The ceiling light should illuminate immediately.

Image 5.1: Detailed Installation Steps
This image provides a visual guide for the installation process, showing how to detach the mounting bracket, fix it to the ceiling, connect wires using the wiring port, and finally mount the light fixture.
6. Operating Instructions
The Airand LED Ceiling Light Fixture is designed for straightforward operation.
- Power On/Off: Control the light using a standard wall switch.
- Non-Dimmable: This fixture is non-dimmable. Do not connect it to a dimmer switch, as this may damage the unit or cause improper operation.
7. Maintenance
The Airand LED Ceiling Light Fixture requires minimal maintenance due to its long-lasting LED technology.
- Cleaning: Ensure the power is OFF before cleaning. Wipe the fixture with a soft, dry, or slightly damp cloth. Do not use harsh chemicals, abrasive cleaners, or solvents, as these may damage the finish or electrical components.
- LED Lifespan: The integrated LED chips have an estimated lifespan of 30,000 hours, providing years of maintenance-free illumination under normal use.

Image 7.1: Eye Protection Design
This image highlights the flicker-free and eye-protective design of the light fixture, contributing to a better reading experience and overall visual comfort.
8. Troubleshooting
If you encounter issues with your light fixture, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. | No power supply. Loose wiring connection. Faulty wall switch. | Check circuit breaker. Ensure all wires are securely connected (power OFF first). Test the wall switch with another device or consult an electrician. |
| Light flickers. | Incompatible dimmer switch. Loose wiring. | This fixture is non-dimmable; remove any dimmer switch. Check wiring connections (power OFF first). |
| Light is too dim. | Not designed for dimming. Incorrect expectation of brightness. | This fixture is non-dimmable. Ensure it is used in an appropriate space for its 2050 lumen output. |
9. Warranty and Support
Airand provides a 3-year limited warranty for this LED ceiling lamp. If any failure occurs within this period, Airand promises to offer a free replacement or refund.
For any questions, concerns, or warranty claims, please contact Airand customer support. Contact details are typically found on the product packaging or the official Airand website. Please have your model number (A6005) and purchase information ready when contacting support.