1. Introduction
The BRICARD 6100107 Door Closer is designed to provide controlled and secure closing for various doors, enhancing safety, maintaining environmental seals, and ensuring privacy. This compact standard arm (compass) door closer is suitable for common door sizes and offers an economical, adjustable force format. This manual provides detailed instructions for proper installation, operation, and maintenance to ensure the longevity and optimal performance of your door closer.

Figure 1: BRICARD 6100107 Door Closer with Compass Arm. This image displays the main components of the door closer, including the silver body and the adjustable compass arm.
2. Safety Information
- Always wear appropriate personal protective equipment (PPE), such as safety glasses and gloves, during installation.
- Ensure the door is securely propped open or removed from its hinges before beginning installation to prevent accidental closure.
- Do not attempt to disassemble the door closer unit. It contains pressurized components.
- Keep children and pets away from the work area during installation and adjustment.
- Verify that the mounting surface is structurally sound and capable of supporting the weight and forces exerted by the door closer.
3. Package Contents
Please check the package for the following items:
- BRICARD 6100107 Door Closer Unit
- Compass Arm Assembly
- Mounting Screws and Hardware
- Installation Template
- Instruction Manual (this document)
4. Specifications
| Feature | Specification |
|---|---|
| Model Number | 6100107 |
| Brand | BRICARD |
| Item Weight | 1.56 kg (3.43 lbs) |
| Product Dimensions (L x W x H) | 179 x 44 x 63 mm (7.05 x 1.73 x 2.48 inches) |
| Installation Type | Screw-In |
| Recommended Use | Secure and control closure of external doors |
| Force (EN) | 2 to 4 (up to 80 kg door weight) |
| Maximum Opening Angle | 180° |
| Operating Temperature | -15°C to +40°C |
| Material | Stainless Steel |
| Color | Silver (RAL 9006) |
| Certifications | CE |
5. Setup and Installation
The BRICARD 6100107 door closer is designed for quick and easy installation. It is reversible, allowing for installation on both left-hand and right-hand opening doors.
5.1. Preparing for Installation
- Determine the desired mounting position: The door closer can be mounted on the push side of the door (standard installation) or the pull side (top jamb installation). Refer to the included installation template for specific hole patterns.
- Ensure the door frame and door material are suitable for screw-in installation.
- Clean the mounting surface to ensure proper adhesion of the template.
5.2. Mounting the Door Closer Unit
- Apply Template: Use the provided installation template. Adhere it firmly to the door and door frame at the chosen mounting location. The template will indicate the precise drilling points for the door closer body and the arm bracket.
- Drill Pilot Holes: Carefully drill pilot holes at the marked points on the door and frame according to the template's specifications. Ensure the drill bit size matches the recommended size for the provided screws.
- Mount Closer Body: Attach the main body of the door closer to the door using the appropriate screws. Ensure it is level and securely fastened.
- Attach Arm Bracket: Secure the arm bracket to the door frame using the remaining screws.
- Assemble Arm: Connect the compass arm to the door closer body and the arm bracket. Ensure all connections are tight.

Figure 2: Dimensional Diagram. This diagram provides precise measurements for the door closer unit and its mounting points, crucial for accurate installation.

Figure 3: Installation and Adjustment Points. This illustration highlights the reversible nature of the device and the location of the two adjustment screws (labeled 1 and 2) for fine-tuning the closing speed and final latch action.
6. Operating Instructions
The BRICARD 6100107 door closer features two adjustment screws for precise control over the door's closing cycle.
6.1. Adjusting Closing Speed (180° - 15°)
The first adjustment screw (labeled 1 in Figure 3) controls the main closing speed of the door from its fully open position (180°) down to approximately 15° from the closed position.
- Turn the screw clockwise to decrease the closing speed (slower).
- Turn the screw counter-clockwise to increase the closing speed (faster).
Make small adjustments (quarter turns) and test the door's closing action after each adjustment.
6.2. Adjusting Final Latch Action / Kick (15° - 0°)
The second adjustment screw (labeled 2 in Figure 3) controls the speed of the final 15° of the closing cycle, often referred to as the 'latch action' or 'kick'. This adjustment is crucial for ensuring the door fully closes and latches without slamming.
- Turn the screw clockwise to decrease the latching speed (slower, softer close).
- Turn the screw counter-clockwise to increase the latching speed (faster, stronger kick).
Adjust this screw to ensure the door closes completely and latches securely without excessive force.
7. Maintenance
The BRICARD 6100107 Door Closer is designed for minimal maintenance. Regular checks can help ensure its continued performance.
- Periodic Inspection: Annually inspect all mounting screws and connections to ensure they remain tight. Tighten any loose screws.
- Cleaning: Wipe the exterior of the door closer with a soft, damp cloth to remove dust and grime. Do not use abrasive cleaners or solvents.
- Lubrication: The internal mechanism is factory-lubricated and sealed. No additional lubrication is required.
- Functionality Check: Periodically open and close the door to ensure the closer operates smoothly and the closing and latching speeds are still set correctly. Readjust if necessary.
8. Troubleshooting
If you encounter issues with your door closer, refer to the table below for common problems and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Door slams shut | Closing speed or latching speed set too fast. | Adjust screw 1 (closing speed) and/or screw 2 (latching speed) clockwise to slow down. |
| Door does not close completely / latch | Closing speed or latching speed set too slow; insufficient force. | Adjust screw 1 and/or screw 2 counter-clockwise to increase speed. Ensure door hinges are not binding. |
| Door closer leaks fluid | Internal seal failure; unit damage. | This indicates a serious issue. The unit cannot be repaired. Contact customer support for warranty claim. |
| Door closer makes excessive noise | Loose mounting screws; internal issue. | Check and tighten all mounting screws. If noise persists, contact customer support. |
9. Warranty and Support
The BRICARD 6100107 Door Closer is backed by a 10-year warranty from the date of purchase, covering defects in materials and workmanship under normal use and service.
This warranty does not cover damage resulting from improper installation, misuse, abuse, unauthorized repairs, or normal wear and tear.
For warranty claims or technical support, please contact BRICARD customer service through the retailer where the product was purchased or visit the official BRICARD website for contact information.