Leeson Electric CZ6T17WC376A
Leeson Electric CZ6T17WC376A General Purpose Washdown Duty Motor User Manual
Model: CZ6T17WC376A | Brand: Leeson Electric
1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Leeson Electric CZ6T17WC376A General Purpose Washdown Duty Motor. This motor is designed for demanding environments requiring frequent washdowns, featuring a stainless steel construction for durability and corrosion resistance. Please read this manual thoroughly before attempting any procedures to ensure proper handling and to prevent injury or damage to the equipment.

Figure 1: Leeson Electric CZ6T17WC376A General Purpose Washdown Duty Motor. This image shows the motor's robust stainless steel construction, including the fan cover at one end and the conduit box for electrical connections. The motor shaft is visible at the opposite end.
2. Safety Information
WARNING: Failure to follow these safety instructions can result in serious injury, death, or equipment damage.
- Always disconnect power before performing any installation, maintenance, or inspection procedures. Lock out and tag out the power source to prevent accidental re-energization.
- Installation and wiring must be performed by qualified personnel in accordance with all national and local electrical codes and safety regulations.
- Ensure proper grounding of the motor to prevent electrical shock.
- Protect rotating parts. Keep hands, clothing, and tools clear of the motor shaft and any connected equipment during operation.
- Do not operate the motor in environments exceeding its specified temperature or humidity ratings.
- Wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when working with the motor.
- Verify that the motor's voltage and frequency ratings match the power supply before connection.
3. Setup and Installation
- Unpacking and Inspection: Carefully remove the motor from its packaging. Inspect for any visible damage that may have occurred during shipping. Report any damage to the carrier immediately.
- Mounting: This motor features a C-Face Flange mounting type. Ensure the mounting surface is flat, rigid, and capable of supporting the motor's weight (approximately 60 lbs) and any connected load. Secure the motor using appropriate fasteners.
- Alignment: Proper alignment between the motor shaft and the driven equipment is crucial to prevent premature bearing failure and vibration. Use precision alignment tools for optimal results.
- Electrical Connections:
- Ensure the power supply is disconnected and locked out.
- Connect the motor to a 3-phase power supply matching the motor's voltage rating (208-230/460 V). Refer to the motor's nameplate for specific wiring diagrams.
- Ensure all connections are tight and properly insulated.
- Verify proper grounding.
- Initial Start-up: Before applying full load, perform a no-load test run to check for unusual noises, vibrations, or overheating. Verify correct rotation direction.
4. Operating Instructions
The Leeson Electric CZ6T17WC376A motor is designed for continuous duty in washdown environments. Once properly installed and connected, operation typically involves energizing the motor circuit. Observe the following:
- Monitoring: Regularly monitor the motor for unusual noises, excessive vibration, or overheating during operation.
- Load Management: Do not exceed the motor's rated horsepower (2 hp) or service factor (1.15). Overloading can lead to premature failure.
- Environmental Conditions: While designed for washdown, avoid direct high-pressure spray on the motor's electrical connections or bearings. Ensure proper drainage around the motor.
- Stopping: De-energize the motor circuit to stop operation.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your washdown duty motor.
- Cleaning: The stainless steel construction and TEFC enclosure make this motor suitable for washdown. Use mild detergents and low-pressure water for cleaning. Avoid harsh chemicals or high-pressure sprays directly on seals or electrical components.
- Bearing Inspection: The motor is equipped with ball bearings. While often sealed for life, periodic inspection for noise or excessive heat can indicate wear. Consult a qualified technician for bearing replacement if necessary.
- Shaft and Coupling: Inspect the motor shaft and coupling for wear, corrosion, or misalignment. Address any issues promptly.
- Electrical Connections: Periodically check all electrical connections for tightness and signs of corrosion.
- Ventilation: Ensure the fan cover and cooling fins are free from debris to maintain proper airflow and prevent overheating.
6. Troubleshooting
Refer to the following table for common issues and their potential solutions. Always disconnect power before troubleshooting.
| Problem | Possible Cause | Solution |
|---|---|---|
| Motor does not start | No power, incorrect wiring, tripped overload, seized bearings. | Check power supply, verify wiring, reset overload, inspect bearings. |
| Motor overheats | Overload, insufficient ventilation, incorrect voltage, bearing issues. | Reduce load, clear fan/fins, verify voltage, inspect bearings. |
| Excessive vibration | Misalignment, loose mounting, unbalanced load, worn bearings. | Check alignment, tighten mounting bolts, balance load, inspect bearings. |
| Unusual noise | Worn bearings, foreign object, loose components. | Inspect bearings, check for obstructions, tighten loose parts. |
If the problem persists after attempting these solutions, contact a qualified service technician or Leeson Electric support.
7. Specifications
| Specification | Value |
|---|---|
| Model Number | CZ6T17WC376A (Manufacturer Part Number: 119524) |
| Motor Category | General Purpose Motor (Stainless Steel) |
| Motor Phase | 3 ph |
| Motor Horsepower | 2.00 hp |
| Synchronous RPM | 1800 rpm |
| Motor Supply Voltage | 208-230/460 V |
| Frame Size | 56C |
| Enclosure Type | TEFC (Totally Enclosed Fan Cooled) |
| Frequency Rating | 50/60 Hz |
| Mounting Type | C-Face Flange |
| Thermal Protection | None |
| Full Load Efficiency | 0.87 % |
| Motor Poles | 4-pole |
| Shaft Diameter | 0.63 in |
| Overall Length (C-Dimension) | 13.19 in |
| Bearing Type | Ball |
| NEMA Design Class | B |
| Service Factor | 1.15 |
| Insulation Class | F4 |
| IP Rating | 69 |
| Material | Stainless Steel |
| Weight | 60 lbs |
8. Warranty and Support
This Leeson Electric CZ6T17WC376A motor comes with a 3-Year Warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service.
For technical support, warranty claims, or service inquiries, please contact Leeson Electric customer service or an authorized service center. Ensure you have your motor's model number (CZ6T17WC376A) and serial number (if applicable) available when contacting support.
Ask a question about this manual