Shyfour 1
User Manual for Shyfour LIPO-Light Machine
Model: 1
1. Product Overview
The Shyfour LIPO-Light Machine (Model: 1) is designed for body shaping and fat reduction. It utilizes LIPO-Light Nano Technology, a non-invasive method to target and reduce small fat deposits. This process is intended to be less painful and have a shorter recovery time compared to surgical liposuction, with a lower risk of loose skin.

Figure 1: The Shyfour LIPO-Light Machine with its main unit and six red light pads extended, ready for use.

Figure 2: Illustration of LIPO-Light pads applied to the body, demonstrating the non-invasive nature of the technology.
2. Safety Information
Please read all instructions carefully before using the device. Adhere to all safety guidelines to ensure proper operation and prevent injury.
- This device is for professional salon and spa use only.
- Ensure the voltage matches your local power supply (AC110V-240V/50Hz-60Hz).
- Do not operate the machine if it is damaged or malfunctioning.
- Keep the device away from water or excessive moisture.
- Use only the provided accessories.
- Wear the provided goggles during operation to protect your eyes from the light.
- The device operates with air cooling. Ensure proper ventilation during use.
- Environmental requirements: 0-40 Degree Celsius, Non-condensing humidity Below 75%RH.
3. Package Contents
Verify that all items listed below are present in your package:
- HKS907 LIPO-Light Machine Main Unit
- 6 LIPO-Light Pads (total 54 diodes)
- Elastic Bands (for securing pads)
- Power Cord
- Goggles (eye protection)

Figure 3: The LIPO-Light Machine with its pads in a folded position, illustrating its compact form factor.
4. Setup
Follow these steps for initial setup:
- Unpack all components from the box.
- Place the main unit on a stable, flat surface.
- Connect the power cord to the main unit and then to a suitable electrical outlet.
- Attach the LIPO-Light pads to the main unit as indicated in the diagram (refer to the physical manual for detailed diagrams if available).
- Ensure all connections are secure before powering on the device.
5. Operating Instructions
The LIPO-Light treatment can be performed in an office setting or at home. A typical session takes approximately 30-60 minutes, and normal activities can be resumed immediately afterward. No anesthesia is involved.

Figure 4: The LIPO-Light Machine in active operation, with its pads glowing red, indicating the emission of light.
Application Process:
- Identify the area of the body to be treated.
- Attach the paddle-like applicators (LIPO-Light pads) to the target area using the provided elastic bands.
- Ensure the pads are in direct contact with the skin.
- Power on the machine.
- Select the desired mode of operation:
- Continuous Mode: Recommended for light skin types.
- Pulse Mode: Recommended for dark skin types.
- Set the treatment duration (e.g., 20, 30, 40, 50, or 60 minutes).
- The pads will emit light that penetrates the skin and heats up the fat cells underneath. This process is designed to damage the membranes of the fat cells, leading to their dissolution. The body then naturally absorbs the dissolved fat cells.
- After the session, power off the machine and remove the pads.
It typically takes about 8-12 weeks to observe the final results of the treatment. Consistent use is key for optimal outcomes. Some individuals may require more than one treatment cycle for desired results.

Figure 5: Visual representation of the LIPO-Light treatment process, including the application of pads and the expected timeframe for results.
6. Maintenance
Proper maintenance ensures the longevity and optimal performance of your LIPO-Light Machine.
- Cleaning: Wipe the main unit and pads with a soft, dry cloth after each use. Do not use abrasive cleaners or immerse the device in water.
- Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it in its original packaging or a protective case when not in use.
- Cord Care: Avoid kinking or bending the power cord excessively. Do not place heavy objects on the cord.
7. Troubleshooting
If you encounter issues with your LIPO-Light Machine, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Power cord not properly connected; power outlet malfunction; device internal issue. | Check power cord connection. Try a different outlet. If problem persists, contact customer support. |
| Pads are not emitting light. | Pads not securely connected; selected mode is incorrect; internal diode issue. | Ensure pads are firmly connected. Verify correct mode (Continuous/Pulse) is selected. If individual pads fail, contact support. |
| Machine resets or turns off during operation. | Power supply instability; overheating; internal component issue. | Ensure stable power supply. Allow device to cool if it feels warm. Contact customer support for persistent issues. |
For issues not listed here, or if the suggested solutions do not resolve the problem, please contact Shyfour customer support.
8. Specifications
Technical specifications for the HKS907 LIPO-Light Machine:
- Model: 1 (HKS907)
- Wave Length: 635/650nm
- Energy Output: 54 * 150mW
- Voltage: AC110V-240V/50Hz-60Hz
- Diode Laser Type: Mitsubishi ML 101J27
- Safety Classification: Electrical Class 1, Type B applied part
- Cooling Requirements: Air cooling
- Mode of Operation: Continuous/Pulse
- Diodes Standard: 54 Diodes (across 6 pads)
- Environmental Requirements: 0-40°C (Non-condensing humidity Below 75%RH)
- Package Size: 18 x 13 x 7 inches
- Weight: 14 LBS (approx. 6.35 kg)
- UPC: 791571202657
- ASIN: B08HLRBGKD
9. Warranty and Support
Shyfour stands behind the quality of its products. For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official Shyfour website.
Please retain your proof of purchase for warranty claims.