Gree GUD85T/A-T, GUD85W/NhA-T

Gree 30000 BTU R32 8-Way Monocassette Air Conditioner User Manual

Models: GUD85T/A-T (Indoor Unit), GUD85W/NhA-T (Outdoor Unit)

1. Introduction

Thank you for choosing the Gree 30000 BTU R32 8-Way Monocassette Air Conditioner. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your air conditioning system. Please read this manual thoroughly before using the product and keep it for future reference.

This system is designed for mono-applications in small commercial and tertiary areas, including shops, offices, meeting rooms, hotels, restaurants, clubs, gyms, and open spaces.

Gree 8-Way Monocassette Indoor Unit and Outdoor Unit

Image 1.1: The Gree 8-Way Monocassette Air Conditioner system, showing both the indoor cassette unit designed for ceiling installation and the outdoor condenser unit.

2. Safety Information

Please observe the following safety precautions to prevent injury or damage to property. Improper operation due to ignoring instructions may cause harm or damage.

  • Installation must be performed by qualified and authorized personnel in accordance with national wiring regulations and this manual.
  • Do not attempt to repair, relocate, or modify the air conditioner yourself. Contact qualified service personnel for any service needs.
  • Ensure the power supply matches the specifications of the unit.
  • The unit uses R32 refrigerant. Handle with care and ensure proper ventilation during installation and servicing. R32 is a mildly flammable refrigerant.
  • Do not insert fingers or objects into the air inlet/outlet.
  • Keep the remote control away from children.
  • Ensure the drainage pipe is properly installed to prevent water leakage.

3. Product Features

The Gree Monocassette Air Conditioner offers advanced features for optimal comfort and efficiency:

  • 8-Way Air Supply: Provides 360° airflow distribution for uniform temperature throughout the room.
  • Oscillation Range: Flaps oscillate between 45° and 80°, adjusted automatically based on heating or cooling mode for maximum comfort.
  • Optimized Fan: Features aerodynamically optimized fan profiles for quiet operation.
  • Integrated Condensate Drain Pump: Capable of lifting condensate water up to 1100 mm, simplifying installation.
  • Compact Design: Attractive and space-saving design suitable for various interior aesthetics.
  • R32 Refrigerant: Utilizes R32 refrigerant, known for its lower environmental impact.
  • Infrared Remote Control: Included for convenient operation.

4. Setup and Installation

Installation of this air conditioning system requires specialized knowledge and tools. It must be carried out by certified professionals to ensure safety, proper functioning, and compliance with local regulations.

4.1. Components Included

  • Indoor Unit (Model: GUD85T/A-T)
  • Outdoor Unit (Model: GUD85W/NhA-T)
  • Cover Grille TF06 (TL10000220)
  • Infrared Remote Control

4.2. Pre-Installation Considerations

  • Location: Choose a location for the indoor unit that allows for even air distribution and easy access for maintenance. The outdoor unit should be placed in a well-ventilated area, away from direct sunlight or heat sources.
  • Structural Support: Ensure the ceiling structure can adequately support the weight of the indoor unit and panel.
  • Electrical Supply: Verify that the electrical supply meets the unit's requirements (220-240 V / 50 Hz / 1 Ph).
  • Refrigerant Piping: Plan the routing for the liquid and gas refrigerant lines (3/8" and 5/8" diameter respectively).
  • Drainage: Ensure proper routing for the condensate drain pipe, utilizing the integrated drain pump.

4.3. Installation Steps (Overview for Professionals)

  1. Prepare the ceiling opening for the indoor unit.
  2. Install the indoor unit and secure it to the ceiling structure.
  3. Mount the outdoor unit in its designated location.
  4. Connect the refrigerant piping between the indoor and outdoor units.
  5. Perform vacuuming and refrigerant charging (if necessary).
  6. Connect the electrical wiring according to the wiring diagram.
  7. Install the cover grille TF06.
  8. Test the system for proper operation.

5. Operating Instructions

Your Gree Monocassette Air Conditioner is operated using the included infrared remote control. Familiarize yourself with the remote control functions for optimal use.

5.1. Basic Functions

  • Power ON/OFF: Press the power button to turn the unit on or off.
  • Mode Selection: Select desired operating mode: Cooling, Heating, Fan, or Dehumidification.
  • Temperature Adjustment: Use the temperature up/down buttons to set your desired room temperature.
  • Fan Speed: Adjust the fan speed (e.g., Low, Medium, High, Auto). The unit supports 4/2 fan speed settings.
  • Swing/Louver Control: Activate the 8-way airflow and 360° oscillation feature for even air distribution.

5.2. Dehumidification

In Dehumidification mode, the unit removes excess moisture from the air. The dehumidification rate is approximately 2.8 liters per hour.

6. Maintenance

Regular maintenance ensures the longevity and efficient operation of your air conditioner. Always turn off the power supply before performing any maintenance.

6.1. Air Filter Cleaning

The air filters should be cleaned regularly (e.g., every two weeks or as needed) to maintain airflow and efficiency. Refer to the indoor unit's access panel for filter removal and cleaning instructions. Wash filters with mild detergent and water, then dry completely before reinstallation.

6.2. Outdoor Unit Cleaning

Periodically clean the outdoor unit's coils and fins to remove dust, leaves, and debris. Ensure the area around the outdoor unit is clear of obstructions to allow for proper airflow.

6.3. Professional Servicing

It is recommended to have your air conditioning system inspected and serviced by a qualified technician at least once a year. This includes checking refrigerant levels, electrical connections, and overall system performance.

7. Troubleshooting

If you encounter issues with your air conditioner, refer to the following common troubleshooting steps. If the problem persists, contact qualified service personnel.

ProblemPossible CauseSolution
Unit does not turn onNo power supply; Remote control batteries depletedCheck circuit breaker; Replace remote control batteries
Insufficient cooling/heatingDirty air filters; Blocked outdoor unit; Incorrect temperature setting; Doors/windows openClean air filters; Clear obstructions from outdoor unit; Adjust temperature; Close doors/windows
Unusual noiseLoose parts; Obstruction in fanTurn off unit and inspect for loose parts or obstructions. Contact service if noise persists.
Water leakage from indoor unitBlocked drain pipe; Improper installationCheck and clear drain pipe; Contact installer for inspection.

8. Specifications

Detailed technical specifications for the Gree 30000 BTU R32 Monocassette Air Conditioner:

SpecificationValue
Cooling Capacity8.5 kW (30000 BTU)
Heating Capacity8.8 kW
SEER (Seasonal Energy Efficiency Ratio)6.1
SCOP (Seasonal Coefficient of Performance)4.0
Energy Class (Cooling)A++
Energy Class (Heating)A+
Power Supply220-240 V / 50 Hz / 1 Ph
Power Consumption (Cooling)2.80 kW
Power Consumption (Heating)2.65 kW
Refrigerant TypeR32
Refrigerant Charge1.80 kg / T.CO2 eq. 1.23
Airflow (Indoor Unit)1400-1310-1180-1040 m³/h
Fan Speed Settings4/2
Dehumidification Rate2.8 l/h
Sound Pressure (Indoor Unit)Max 50 dB(A) - Min 42 dB(A)
Liquid Pipe Diameter3/8" (9.52mm)
Gas Pipe Diameter5/8" (15.88mm)
Indoor Unit Dimensions (HxWxD)240 x 840 x 840 mm
Indoor Unit Weight (without packaging)29 kg
Outdoor Unit Dimensions (HxWxD)790 x 920 x 370 mm
Outdoor Unit Weight (without packaging)60 kg
Panel/Grille Dimensions (HxWxD)52 x 950 x 950 mm
Panel/Grille Weight (without packaging)6 kg

9. Warranty and Support

Gree products are distributed by ARGO, a historical Italian company specializing in air conditioning since 1929. Support for your Gree air conditioner is guaranteed by ARGO-approved service centers nationwide.

For warranty claims, technical assistance, or to locate an authorized service center, please refer to the contact information provided with your purchase documentation or visit the official ARGO website.

Related Documents - GUD85T/A-T, GUD85W/NhA-T

Preview GREE GMV-ND30T/NhD-T(U) 208-230V Ceiling Cassette Air Conditioner Specifications and Dimensions
Technical specifications, performance data, and physical dimensions for the GREE GMV-ND30T/NhD-T(U) 208-230V Ceiling Cassette Air Conditioner. Includes electrical data, refrigerant piping, and installation clearances.
Preview Gree GMV6 Mini DC Inverter VRF Outdoor Units Exploded View and Parts List
Detailed exploded view and parts list for Gree GMV6 Mini DC Inverter VRF Outdoor Units, covering models GMV-V36WL/NhC-T(U), GMV- V48WL/NhC-T(U), and GMV- V60WL/NhC-T(U). Includes part numbers, quantities, and contact information for Gree Electric Appliances.
Preview Gree Ultra Heat GMV5 Multi VRF Technical Sales Guide
This technical sales guide provides comprehensive information on the Gree Ultra Heat GMV5 Multi VRF air conditioning system, detailing product features, system equipment, controller options, selection procedures, refrigerant piping design, wiring principles, technical specifications, and installation dimensions.
Preview GREE GMV-ND36PHS/NhD-T(U) High Static Duct Type Air Conditioner Submittal Data
Submittal data sheet for the GREE GMV-ND36PHS/NhD-T(U) 208~230V High Static Duct Type air conditioner, including performance specifications, electrical data, dimensions, and refrigerant piping details.
Preview GREE Ultra Heat GMV Multi VRF System for North America - Technical Manual
Comprehensive technical manual for the GREE Ultra Heat GMV Multi VRF system, covering product specifications, installation, control, maintenance, and troubleshooting for North American applications.
Preview Gree Energy Recovery Ventilation System Service Manual
Comprehensive service manual for Gree Energy Recovery Ventilation Systems (ERV), covering product specifications, operation principles, installation guides, maintenance procedures, and troubleshooting for models like FHBQGL-D1.5DA-T, FHBQGL-D2.5DA-T, FHBQGL-D3.5DA-T, and FHBQGL-D5DA-T.