1. Introduction
The Generic SFXD-CD05A Disinfection ULV Cold Fogger Sprayer is a versatile and efficient device designed for a wide range of applications requiring fine mist dispersion. Utilizing the principle of air atomization and negative pressure adsorption, it produces very fine particles for effective disinfection, sterilization, epidemic prevention, air purification, disease prevention, and pest control.
This manual provides essential information for the proper use and maintenance of your fogger, ensuring optimal performance and safety.

Figure 1.1: Front view of the Disinfection ULV Cold Fogger Sprayer.

Figure 1.2: The ULV Fogger Sprayer highlighting its primary functions: sterilization, insecticidal application, and humidification.
2. Safety Instructions
Read all safety warnings and instructions before operating the device. Failure to follow the warnings and instructions may result in electric shock, fire, or serious injury.
- Electrical Safety: Ensure the power supply matches the device's requirements (220V). Do not operate with damaged cords or plugs. Always turn off the power immediately if unusual sounds are heard during operation.
- Chemical Handling: This fogger handles both oil- and water-based chemical solutions. Always wear appropriate personal protective equipment (PPE) such as gloves, eye protection, and a respirator when handling and spraying chemicals. Refer to the chemical manufacturer's safety data sheet (SDS) for specific handling instructions.
- Ventilation: Use the fogger in well-ventilated areas. Avoid inhaling the mist directly.
- Storage: Store the device in a cool, dry place, away from direct sunlight and out of reach of children.
- Maintenance Safety: Always unplug the device from the power source before performing any cleaning or maintenance.
- Emergency Shutdown: In case of malfunction or unusual operation, immediately turn off the power and unplug the device.
3. Product Components
Familiarize yourself with the main components of your ULV Cold Fogger Sprayer:
- Main Unit: Houses the motor and internal mechanisms.
- Solution Tank: 5-liter capacity for holding chemical solutions. Features a semi-transparent design with a scale for convenient and precise solution mixing.
- Nozzle Assembly: Adjustable nozzle for controlling particle size (10-150µm).
- Hose: Flexible hose connecting the main unit to the nozzle assembly.
- Filter Element: Easy-to-pull type base filter design for quick replacement.
- Power Cord: For connecting to a 220V power source.
- Portable Straps: For convenient carrying and operation.

Figure 3.1: Side view of the fogger, showing the main unit and the attached nozzle assembly.

Figure 3.2: Detailed view of the adjustable nozzle and the easy-to-pull filter element.
4. Setup
- Unpack: Carefully remove the fogger and all accessories from the packaging. Inspect for any damage.
- Positioning: Place the fogger on a stable, level surface before filling.
- Fill Solution Tank: Unscrew the cap of the 5-liter solution tank. Carefully pour the desired oil- or water-based chemical solution into the tank. Use the integrated scale for accurate measurement. Do not overfill. Securely close the cap.
- Connect Power: Ensure the fogger's power switch is in the OFF position. Plug the power cord into a grounded 220V electrical outlet.
- Adjust Particle Size (Optional): If specific particle size is required, adjust the nozzle with different aperture settings. The particle size is adjustable from 10-150µm.
5. Operating Instructions
Follow these steps for safe and effective operation of your ULV Cold Fogger Sprayer:
- Preparation: Ensure the solution tank is filled with the appropriate chemical and the power cord is securely plugged in. Wear all necessary personal protective equipment (PPE).
- Power On: Turn the power switch to the ON position. The motor will start, and the fogger will begin to atomize the solution.
- Adjust Atomization Volume: The atomization volume is adjustable, with a maximum of 470ml/min. Adjust as needed for your application.
- Application: Direct the nozzle towards the area to be treated. Maintain an effective range of 3-8 meters for optimal coverage. Move steadily to ensure even distribution of the fog.
- Power Off: Once the application is complete, turn the power switch to the OFF position.
- Unplug: Disconnect the power cord from the electrical outlet.

Figure 5.1: Examples of the ULV fogger being used for disinfection in different environments.
6. Maintenance
Regular maintenance ensures the longevity and efficient operation of your fogger:
- Cleaning After Use: If the machine is not used for a long time, or after using certain chemicals, fill the tank with clean water and spray it for approximately 1 minute. This helps to flush out residual chemicals and prevent clogging.
- Filter Element Replacement: The unique easy-to-pull type base filter design allows for quick replacement of the filter element. Regularly inspect the filter and replace it when it appears dirty or clogged to ensure optimal performance and prevent damage to the motor.
- Exterior Cleaning: Wipe the exterior of the fogger with a damp cloth. Do not use harsh chemicals or abrasive cleaners.
- Storage: After cleaning, ensure the tank is empty and dry. Store the fogger in a dry, cool place.
7. Troubleshooting
This section addresses common issues you might encounter with your ULV Cold Fogger Sprayer:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fogger does not turn on. | No power supply; Power switch off; Damaged power cord. | Check power outlet; Ensure switch is ON; Inspect power cord for damage and replace if necessary. |
| No mist or weak mist. | Solution tank empty; Nozzle clogged; Filter clogged; Incorrect particle size setting. | Refill tank; Clean nozzle; Clean or replace filter; Adjust particle size setting. |
| Unusual sounds during operation. | Internal malfunction; Obstruction in motor/pump. | Immediately turn off power and unplug. Do not attempt to repair. Contact customer support. |
| Leakage from tank or hose. | Tank cap not secured; Hose connection loose; Damaged tank/hose. | Ensure tank cap is tightly closed; Check and tighten hose connections; If damaged, contact customer support for replacement parts. |
If the problem persists after attempting these solutions, please contact customer support.
8. Specifications
Technical specifications for the Disinfection ULV Cold Fogger Sprayer (Model: SFXD-CD05A):
| Parameter | Value |
|---|---|
| Model | SFXD-CD05A |
| Type | 5L Disinfection ULV Cold Fogger Sprayer Electric Portable ULV Fogger |
| Atomization Volume | 470ml/min (adjustable) |
| Particle Size | 10-150µm (adjustable) |
| Effective Range | 3-8 Meters |
| Motor Voltage | 220V |
| Power | 1000W |
| Tank Capacity | 5 Liters / 1.1 Gallons |
| Net / Gross Weight | 2.61 kg / 3.78 kg |
| Dimensions (L*W*H) | 560*240*320mm |
| Chemical Compatibility | Handles both oil- and water-based chemical solutions |

Figure 8.1: Visual representation of the 5L capacity and 3-8 meter spray distance.
9. Warranty and Support
This product comes with a standard manufacturer's warranty. Please refer to your purchase documentation for specific warranty terms and conditions.
For technical support, troubleshooting assistance beyond what is covered in this manual, or to inquire about replacement parts, please contact your retailer or the manufacturer's customer service department. Keep your purchase receipt and model number (SFXD-CD05A) handy when contacting support.