1. Introduction
Thank you for choosing the Airton Portable Reversible Air Conditioner. This appliance is designed to provide both cooling and heating for your indoor spaces, along with fan and dehumidification functions. This manual provides essential information for the safe and efficient use of your air conditioner. Please read it thoroughly before installation and operation, and retain it for future reference.
This model, with a cooling capacity of 3500W (12000 BTU) and heating capacity of 2500W, is suitable for areas between 30m² and 35m².

Figure 1: Approximate coverage area of the Airton Portable Air Conditioner.
2. Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury.
- Read all instructions before using the appliance.
- Ensure the power supply matches the voltage specified on the rating label.
- Do not operate the appliance with a damaged cord or plug.
- Do not block air inlets or outlets.
- Keep the appliance away from heat sources and direct sunlight.
- Do not use the appliance in wet environments or near water.
- Unplug the appliance before cleaning or servicing.
- This appliance uses R-290 refrigerant, which is flammable. Handle with care and ensure proper ventilation.
- Do not attempt to repair or modify the appliance yourself. Contact qualified service personnel.
- Keep children and pets away from the appliance during operation.
3. Product Overview
3.1 Components
The Airton Portable Reversible Air Conditioner includes the main unit, an exhaust hose, a condensation hose, and a window sealing kit.

Figure 2: Airton Portable Air Conditioner components and dimensions.
3.2 Rear View
The rear of the unit features the air intake, exhaust outlet, and drainage points.

Figure 3: Rear view of the Airton Portable Air Conditioner.
3.3 Control Panel and Remote Control
The unit features a digital display for selecting functions and monitoring settings. A remote control is provided for convenient operation from a distance.
- Digital Display: Shows temperature, mode, and timer settings.
- Remote Control: Allows adjustment of mode, temperature, fan speed, and timer.
4. Setup and Installation
4.1 Positioning the Unit
- Place the air conditioner on a flat, stable surface.
- Ensure there is at least 30 cm (12 inches) of space around the unit for proper airflow.
- Position the unit near a window or opening for exhaust hose installation.

Figure 4: Example of unit placement near a window.
4.2 Exhaust Hose Installation
- Attach one end of the exhaust hose to the air outlet on the rear of the unit.
- Extend the exhaust hose to the nearest window or opening.
- Use the provided window sealing kit to secure the hose in the window opening, ensuring minimal air leakage.
- Ensure the exhaust hose is as straight and short as possible to maximize efficiency. Avoid sharp bends.
4.3 Condensation Hose Installation (Dehumidification Mode)
For continuous drainage during dehumidification mode, connect the condensation hose to the designated drainage outlet and direct it to a suitable drain or container.
5. Operating Instructions
5.1 Power On/Off
Press the Power button on the control panel or remote control to turn the unit on or off.
5.2 Mode Selection
Press the Mode button to cycle through the available operating modes:
- Cooling Mode: For reducing room temperature. Set desired temperature using the Temperature Up/Down buttons.
- Heating Mode: For increasing room temperature. Set desired temperature.
- Fan Mode: Circulates air without cooling or heating. Adjust fan speed as desired.
- Dehumidification Mode: Removes excess moisture from the air. The unit will operate at a fixed fan speed. Ensure the condensation hose is properly connected for continuous drainage.
5.3 Temperature Adjustment
In Cooling or Heating mode, use the Temperature Up (▲) and Temperature Down (▼) buttons to set your desired temperature.
5.4 Fan Speed Adjustment
Press the Fan Speed button to select between low, medium, and high fan speeds. This function is available in Cooling, Heating, and Fan modes.
5.5 Timer Function
The timer function allows you to program the unit to turn on or off automatically after a set period (up to 24 hours).
- Press the Timer button.
- Use the Temperature Up/Down buttons to set the desired delay in hours.
- Press the Timer button again to confirm.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always unplug the unit before performing any maintenance.
6.1 Cleaning the Air Filter
- The air filter should be cleaned every two weeks, or more frequently depending on usage.
- Remove the air filter from the back of the unit.
- Wash the filter with warm, soapy water. Rinse thoroughly and allow it to air dry completely before reinserting.
- Do not operate the unit without the air filter.
6.2 Draining Accumulated Water
During cooling and dehumidification, water will accumulate inside the unit. The unit has an internal self-evaporation system, but in high humidity conditions, manual drainage may be required.
- When the internal water tank is full, the unit will stop operating and display an error code (e.g., "FL").
- Place a shallow pan or tray under the drainage outlet at the bottom rear of the unit.
- Remove the drain plug and allow the water to drain completely.
- Replace the drain plug securely before resuming operation.
6.3 Cleaning the Unit Exterior
Wipe the exterior of the unit with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
7. Troubleshooting
Before contacting customer support, please refer to the following table for common issues and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power supply. Power cord not plugged in. Internal water tank full. | Check power outlet. Ensure power cord is securely plugged in. Drain the internal water tank. |
| Insufficient cooling/heating. | Air filter clogged. Exhaust hose blocked or improperly installed. Room too large for unit capacity. Doors/windows open. | Clean the air filter. Check exhaust hose for obstructions and proper sealing. Ensure unit is used in appropriate room size. Close all doors and windows. |
| Unit is noisy. | Unit not on a flat surface. Air filter clogged. Normal operating noise (65 dB). | Place unit on a flat, stable surface. Clean the air filter. This unit operates at 65 dB, which is a normal operating sound level for portable air conditioners. |
| Water leakage. | Drain plug loose. Condensation hose improperly connected. | Ensure drain plug is securely tightened. Check condensation hose connection and ensure it is directed to a drain. |
8. Specifications

Figure 5: Energy Efficiency Label.
| Feature | Detail |
|---|---|
| Brand | Airton |
| Model Number | 409614 |
| Cooling Capacity | 3500W (12000 BTU) |
| Heating Capacity | 2500W |
| Air Flow Rate | 400 m³/h |
| Recommended Area | 30-35 m² |
| Functions | Cooling, Heating, Fan, Dehumidifier |
| Refrigerant | R-290 (Natural Hydrocarbon) |
| Noise Level | 65 dB(A) |
| Voltage | 220 Volts |
| Dimensions (D x W x H) | 42 cm x 72.2 cm x 36 cm |
| Weight | 31 kg |
| Energy Efficiency Class | A |
| Control Method | Remote Control, Digital Display |
9. Warranty and Support
This product comes with a limited warranty. Please refer to the warranty card included with your purchase for specific terms and conditions. For technical support, spare parts, or warranty claims, please contact your retailer or the official Airton customer service.
Manufacturer: Airton
Country of Origin: China