Speedaire 13X520

User Manual

Speedaire 13X520 Zero Loss Drain Pilot Operated 1/2 Inch NPT

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Speedaire 13X520 Zero Loss Drain. This device is designed to automatically remove condensate from compressed air systems without air loss, ensuring optimal system performance and longevity. Please read this manual thoroughly before installation and operation.

2. Safety Information

WARNING: Failure to follow these safety instructions may result in serious injury or property damage.

  • Always depressurize the air system before installing, servicing, or removing the drain.
  • Ensure electrical connections are made by a qualified electrician and comply with local codes.
  • Verify the voltage supply (90-260V, 50-60Hz) matches the drain's requirements.
  • Do not exceed the maximum operating pressure of 230 PSI.
  • Wear appropriate personal protective equipment (PPE) during installation and maintenance.
  • Ensure the drain outlet is directed to an appropriate waste disposal system.

3. Product Overview

The Speedaire 13X520 is a pilot-operated, automatic condensate drain designed for robust industrial applications. It features an aluminum body and an IP65 enclosure for durability and protection against dust and water ingress.

Speedaire 13X520 Zero Loss Drain

Figure 1: Speedaire 13X520 Zero Loss Drain. This image shows the external view of the drain unit, highlighting its compact design and robust construction suitable for industrial environments.

4. Setup and Installation

  1. Preparation: Depressurize and drain the compressed air system completely. Ensure the installation location is stable, accessible for maintenance, and within the specified operating temperature range (36 to 180 °F).
  2. Mounting: Mount the drain vertically with the condensate inlet at the top and the drain outlet at the bottom. Ensure sufficient clearance for the bowl and electrical connections.
  3. Air Connection: Connect the 1/2 NPT inlet of the drain to the condensate collection point of your compressed air system. Use appropriate thread sealant. The drain outlet (1/2 inch diameter) should be connected to a suitable waste disposal line.
  4. Electrical Connection: Connect the drain to a 90-260V, 50-60Hz AC power supply. The drain consumes 0.15 Amps AC. Ensure proper grounding and protection against electrical hazards. Refer to local electrical codes for wiring requirements.
  5. Initial Check: Once installed, slowly repressurize the air system and check for any leaks at the connections.

5. Operating Instructions

The Speedaire 13X520 Zero Loss Drain operates automatically once installed and powered. It is a pilot-operated drain, meaning an internal pilot mechanism controls the opening and closing of the drain valve based on condensate levels.

  • Automatic Operation: The drain will sense the condensate level in its 490mL bowl. When the level reaches a predetermined point, the pilot mechanism activates, opening the drain valve to discharge the condensate.
  • Zero Air Loss: The design ensures that only condensate is discharged, preventing the loss of compressed air during the draining cycle.
  • Pilot Pressure: The drain requires a minimum pilot pressure of 11.5 PSI and can operate up to 230 PSI. Ensure your system's pressure falls within this range for proper function.
  • Drain Rate: At 100 PSI, the drain rate is approximately 1.2 GPM (gallons per minute).

6. Maintenance

Regular maintenance ensures the longevity and reliable operation of your Speedaire 13X520 drain.

  • Daily Inspection: Visually inspect the drain for any signs of leaks, damage, or unusual operation.
  • Weekly Cleaning: Depressurize the system and disconnect power. Remove the condensate bowl and clean it thoroughly. Inspect the internal components for debris or blockages. Reassemble carefully, ensuring all seals are properly seated.
  • Annual Service: It is recommended to perform a more thorough inspection annually, checking all connections, electrical wiring, and internal valve components for wear. Replace any worn parts as necessary.

7. Troubleshooting

Refer to the following table for common issues and their solutions.

ProblemPossible CauseSolution
Drain not operating / No condensate dischargeNo power supply
System pressure too low
Drain clogged
Faulty pilot mechanism
Check electrical connections and power source.
Ensure system pressure is above 11.5 PSI.
Depressurize, disconnect power, and clean the drain.
Contact qualified service personnel.
Continuous air loss / Drain constantly openDebris in valve seat
Worn valve seal
Incorrect installation
Depressurize, disconnect power, and clean the valve area.
Replace valve seal.
Verify correct vertical mounting and connections.
Leaks from connectionsLoose fittings
Damaged thread sealant
Tighten connections.
Depressurize, remove, reapply thread sealant, and reassemble.

8. Specifications

FeatureSpecification
Operation TypePilot Operated
Maximum Pressure (PSI)230
Minimum Pressure (PSI)11.5
Drain Rate at 100 PSI (GPM)1.2
Bowl Capacity490 mL
Pilot Pressure Range11.5 to 230 psi
Inlet Connection1/2 NPT
Drain Outlet Diameter1/2 Inch
Operating Temperature (Min./Max.)36 to 180 °F
Voltage90-260V
Frequency50-60Hz
Amperage0.15 Amps AC
Enclosure RatingIP65
Body MaterialAluminum
Height7 Inches
Width3 Inches
Depth7 Inches

9. Warranty and Support

For warranty information or technical support, please refer to the documentation provided with your purchase or contact Speedaire customer service. Keep your purchase receipt for warranty claims.

Related Documents - 13X520

Preview Speedaire 4MU10A Stationary Air Compressor Repair Parts Manual
Comprehensive repair parts manual for the Speedaire 4MU10A Stationary Air Compressor, including specifications, detailed parts lists, illustrations, and warranty information.
Preview Speedaire Air Compressor Repair Parts Manual (4ME97A, 4ME98A)
Official repair parts manual for Speedaire air compressor models 4ME97A and 4ME98A. Includes technical specifications, torque settings, exploded view diagrams, and warranty information.
Preview Speedaire 5 & 7.5 HP Two-Stage Air Compressors: Operating Instructions & Parts Manual
Comprehensive operating instructions and parts manual for Speedaire 5 & 7.5 HP Two-Stage Air Compressors. Covers installation, operation, maintenance, troubleshooting, and parts lists for models 4XA and 1WD series.
Preview Speedaire Permanently Lubricated Twin Cylinder Air Compressor - Operating Instructions & Parts Manual
Operating instructions, safety guidelines, and parts manual for the Speedaire Permanently Lubricated Twin Cylinder Air Compressor (Model 4UP73). Covers setup, operation, maintenance, and troubleshooting for home, farm, and medium-duty industrial use.
Preview Speedaire 1WC94 "Site Boss" Air Compressor: Operating Instructions and Parts Manual
This manual provides operating instructions, safety guidelines, maintenance procedures, and parts lists for the Speedaire 1WC94 "Site Boss" Air Compressor, designed for home, farm, and medium-duty industrial use by Dayton Electric Mfg. Co.
Preview Speedaire Two-Stage Air Compressor Pump Parts Kits Manual (2NYC1, 2NYC2, 2NYC3, 2NYC4)
Comprehensive repair and maintenance manual for Speedaire two-stage air compressor pump kits, including models 2NYC1, 2NYC2, 2NYC3, and 2NYC4. Covers valve and overhaul procedures, torque specifications, and parts lists.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.