1. Introduction
The Infurider YF-38C is a compact, pen-type digital multimeter designed for safe and accurate electrical troubleshooting in various applications, including automotive and household circuits. This device features a 6000-count display and offers automatic ranging for ease of use. It is capable of measuring AC/DC voltage, resistance, capacitance, and continuity, as well as performing diode tests. Its ergonomic design ensures comfortable handling, and integrated features like a backlight and flashlight enhance usability in diverse environments.
2. Safety Information
Always adhere to the following safety precautions to prevent personal injury or damage to the multimeter:
- Ensure the multimeter is in good working condition before use. Inspect test leads for damage.
- Do not apply voltage or current that exceeds the maximum specified limits for the meter. The YF-38C features double insulation protection and is rated CE 600V CAT III.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
- Always disconnect power to the circuit under test before measuring resistance, capacitance, or continuity.
- Do not operate the meter in explosive gas, vapor, or dusty environments.
- Replace batteries immediately when the low battery indicator appears to ensure accurate readings.
- A buzzer will sound when the circuit is disconnected or connected, providing an audible safety alert.
3. Product Features
The Infurider YF-38C Digital Pen Multimeter offers a range of features for efficient electrical testing:
- 6000 Counts Display: Provides high-resolution measurements.
- Auto-Ranging: Automatically selects the correct measurement range.
- AC/DC Voltage Measurement: Measures from 600mV to 600V.
- Resistance Measurement: Measures from 600Ω to 60MΩ.
- Capacitance Measurement: Supports capacitance testing.
- Continuity Test: Audible buzzer for quick circuit checks.
- Diode Test: For checking diode functionality.
- Data Hold: Freezes the displayed reading for convenient recording.
- LCD Backlight: Improves visibility in dimly lit conditions.
- Flashlight: Integrated LED light for illuminating the work area.
- Automatic Power Off: Conserves battery life after a period of inactivity.
- Double Insulation Protection: Enhances user safety.

Figure 1: Key features of the Infurider YF-38C Pen Multimeter.
4. Package Contents
Verify that all items are present in the package:
- Infurider YF-38C Digital Pen Multimeter
- Test Leads (integrated)
- 2 x 1.5V AAA Batteries
- User Manual

Figure 2: Included items in the product package.
5. Device Layout
Familiarize yourself with the components of your YF-38C multimeter:
- LCD Display: Shows measurement readings, units, and function symbols.
- Function Switch: Rotates to select measurement modes (e.g., V~, V-, Ω, CAP, Diode, Continuity).
- HOLD Button: Press to freeze the current reading on the display. Long press to activate/deactivate backlight and flashlight.
- SELECT Button: Used to switch between AC/DC modes or other sub-functions within a main mode.
- Input Jack (Red): For the positive test lead.
- Input Jack (Black): For the common (negative) test lead.
- Flashlight LED: Provides illumination for the work area.
- Battery Compartment: Located at the rear for AAA batteries.

Figure 3: Front view of the YF-38C multimeter.
6. Battery Installation
The YF-38C multimeter requires two 1.5V AAA batteries for operation.
- Locate the battery compartment cover on the back of the multimeter.
- Use a screwdriver to loosen the screw securing the battery cover.
- Remove the cover and insert two AAA batteries, observing the correct polarity (+ and -).
- Replace the battery cover and tighten the screw.
Note: The multimeter will display a low battery indicator when the battery voltage is insufficient for accurate measurements. Replace batteries promptly.

Figure 4: Low battery indication and battery type.
7. Operating Instructions
Follow these steps for various measurement functions:
7.1. AC/DC Voltage Measurement
- Turn the function switch to the 'V~' (AC Voltage) or 'V-' (DC Voltage) position. The meter will automatically select the appropriate range.
- Connect the red test lead to the positive side of the circuit and the black test lead to the negative side (or neutral/ground for AC).
- Read the voltage value on the LCD display.
- Use the SELECT button to switch between AC and DC voltage if the function switch combines them.

Figure 5: Measuring AC Voltage.
7.2. Resistance Measurement
- Ensure the circuit under test is completely de-energized.
- Turn the function switch to the 'Ω' (Resistance) position.
- Connect the test leads across the component or circuit section where resistance is to be measured.
- Read the resistance value on the LCD display.
7.3. Continuity Test
- Ensure the circuit under test is completely de-energized.
- Turn the function switch to the continuity symbol (often shared with resistance or diode).
- Connect the test leads across the circuit or component.
- If the resistance is below approximately 50Ω, the buzzer will sound, indicating continuity.
7.4. Diode Test
- Ensure the circuit under test is completely de-energized.
- Turn the function switch to the diode symbol.
- Connect the red test lead to the anode and the black test lead to the cathode of the diode. The display will show the forward voltage drop.
- Reverse the leads. The display should show 'OL' (Open Line) for a good diode.
7.5. Capacitance Measurement
- Ensure the capacitor is fully discharged before testing to prevent damage to the meter.
- Turn the function switch to the capacitance symbol.
- Connect the test leads across the capacitor terminals.
- Read the capacitance value on the LCD display.
7.6. Data Hold, Backlight, and Flashlight
- Data Hold: Press the 'HOLD' button briefly to freeze the current reading. Press again to release.
- Backlight/Flashlight: Long press the 'HOLD' button to turn on the LCD backlight and the integrated flashlight. Long press again to turn them off.

Figure 6: Backlight, Flashlight, Data Hold, and Auto Power Off features.

Figure 7: Examples of AC Voltage, DC Voltage, Resistance, and Continuity Tests.
8. Maintenance
Proper maintenance ensures the longevity and accuracy of your multimeter:
- Cleaning: Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents.
- Storage: Store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
- Calibration: For professional use, periodic calibration by a qualified technician is recommended to maintain accuracy.
9. Troubleshooting
If you encounter issues with your YF-38C multimeter, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No display or dim display | Dead or low batteries; Incorrect battery installation | Replace batteries; Check battery polarity |
| 'OL' (Overload) displayed | Measurement exceeds selected range; Open circuit | Ensure correct range (auto-ranging should handle most cases); Check for open circuit in continuity/resistance tests |
| Inaccurate readings | Low battery; Poor test lead connection; External interference | Replace batteries; Ensure firm connection of test leads; Move away from strong electromagnetic fields |
| Buzzer not working for continuity | Circuit resistance too high; Meter not in continuity mode | Ensure resistance is below threshold (approx. 50Ω); Select continuity mode |
10. Specifications
Detailed technical specifications for the Infurider YF-38C Digital Pen Multimeter:
| Measurement Function | Range | Resolution | Accuracy |
|---|---|---|---|
| DC Voltage | 600.0mV - 600V | 0.1mV - 1V | ±(0.5% of rdg + 2 digits) for 600mV-60V; ±(0.8% of rdg + 2 digits) for 600V |
| AC Voltage | 6.000V - 600V | 1mV - 1V | ±(1.0% of rdg + 3 digits) for 6V-60V; ±(1.5% of rdg + 3 digits) for 600V |
| Resistance | 600.0Ω - 60.00MΩ | 0.1Ω - 10kΩ | Varies by range (e.g., ±(0.8% of rdg + 5 digits) for 600Ω) |
| Capacitance | Not explicitly detailed in provided specs, but supported. | N/A | N/A |
| Continuity | Audible buzzer below approx. 50Ω | N/A | N/A |
| Diode Test | Forward voltage drop display | N/A | N/A |
General Specifications:
- Display: 6000 Counts LCD
- Power Source: 2 x 1.5V AAA Batteries
- Overload Protection: 600V DC or AC RMS
- Impedance (Voltage): 10MΩ (More than 100MΩ on 600mV range)
- Frequency Range (AC): 40 to 2kHz
- Safety Compliance: CE 600V CAT III, FDA, FCC
- Operating Temperature: Up to 50°C
- Item Weight: 177 Grams
- Package Dimensions: 30.9 x 9.3 x 4.8 cm

Figure 8: Product Specification Test Table.
11. Warranty and Support
Infurider is committed to customer satisfaction. If you are not 100% satisfied with your product, please contact us. Our professional support team is dedicated to resolving any issues and aims to respond within 24 hours. For further assistance or warranty claims, please refer to the contact information provided with your purchase or visit the official Infurider website.