Product Overview
The CALT HB961 is a versatile 6-digit pulse indicator readout designed for industrial automation control. It supports various input signals and external sensors, offering addition and subtraction counting, phase identification, and alarm relay outputs. This manual provides detailed instructions for its installation, operation, and parameter configuration.

Image: Front view of the CALT HB961 Pulse Indicator Readout.
Key Features
- Input Signal Compatibility: Supports switch and pulse inputs (low pulse: -30V~+0.6V, high pulse: +4V~+30V).
- Sensor Support: Compatible with photoelectric tubes, proximity switches, Hall sensors, angle sensors, line grating displacement sensors, and encoders.
- Power Output for Sensors: Provides 5V and 24V DC voltage with 30mA current for external sensors.
- Configurable Parameters: Allows setting of ratio A, ratio B, initial value C, and decimal point position to meet diverse application needs.
- Data Retention: Current total value, alarm settings, and parameter values are retained even after power loss.
- Relay Outputs: Equipped with two relay outputs for scene control, supporting addition, subtraction, and phase identification counting.
Technical Specifications
| Specification | Value |
|---|---|
| Power Supply | AC 85-260V / DC 85-360V |
| Display Dimension | 0.56 inches |
| Relay Contact Capacity | AC 220V / 3A (Resistive load) |
| Relay Contact Life | 105 operations |
| Maximum Frequency | 30KHz (Raster Form: 15KHz) |
| Display Range | -199999 to 999999 |
| Operating Environment | 0℃ to +50℃; < 85%RH |
| Overall Dimensions | 96mm x 48mm x 82mm (Length x Width x Depth) |
| Panel Cutout Dimensions | 92mm x 45mm |

Image: Excerpt from the manual detailing technical specifications and count modes.
Installation and Wiring
Proper installation and wiring are crucial for the correct operation of the HB961 indicator. Refer to the diagrams and terminal descriptions below for guidance.
Terminal Connections
The HB961 features a 20-pin terminal block. Ensure all connections are secure and correctly matched to their functions.
| Terminal No. | Function |
|---|---|
| 1, 2 | AC/DC 85-260V Power Input |
| 3 | 5V DC Output (for sensors) |
| 4 | 30mA Current Output (for sensors) |
| 5, 6, 7 | COM (Common Ground) |
| 8 | RST (Reset Input) |
| 9 | IN2 (Input 2) |
| 10 | IN1 (Input 1) |
| 11, 12 | J2 Relay Output |
| 13, 14 | J1 Relay Output |

Image: Detailed wiring diagram showing connections for an encoder, power, and relay outputs.
Sensor Wiring Notes
- For strong interference or inductive loads, it is recommended to use a 220V AC power supply and relay, incorporating a 250V/220nF capacitance for safety regulations.
- The instrument is factory-configured for NPN type sensors. For PNP sensors, customization is required. If using PNP sensors, a suitable value resistor (recommended 510Ω) should be used for indirect IN and COM connections.

Image: Excerpt from the manual showing terminal configuration and various sensor wiring examples.
Operation and Parameter Settings
The HB961 indicator features a user-friendly interface for setting various operational parameters. The panel includes indicators for J1 and J2, a SET key, a Shift key (decrease numerals), and an Up key (reset key).

Image: Excerpt from the manual detailing the panel layout and parameter setting procedures.
Setting Count Mode
To enter the count mode settings, press the SET key and input the password "PP0089". Use the > and ^ keys to navigate and adjust parameters.
Function Parameters
The following table outlines the key function parameters:
| Symbol | Description | Range | Default Value |
|---|---|---|---|
| r1sn | J1 Output Mode | 1, 2, 3 | 1 |
| r2sn | J2 Output Mode | 1~11 | 1 |
| A | Ratio A | 1~999999 | 1 |
| b | Ratio b | 1~999999 | 1 |
| C | Initial Value | 1~999999 | 0 |
| dot | Decimal Point Position | Last one hot | Last one hot |
| End | End |
Alarm Parameters
To set alarm parameters, press the SET key and input the password "0001". The following table details the alarm parameters:
| Symbol | Description | Range | Default Value |
|---|---|---|---|
| J1 | Relay J1 Alarm Value 1 | 1~999999 | 20000 |
| J2 | Relay J2 Alarm Value 1 | 1~999999 | 10000 |
| J1-2 | Relay J1 Alarm Value 2 | 1~999999 | 40000 |
| J2-2 | Relay J2 Alarm Value 2 | 1~999999 | 30000 |
| J1 delay time | J1 Delay Time | 0.1~999.9 | 0.1 |
| J2 delay time | J2 Delay Time | 0.1~999.9 | 0.1 |
Relay Output Modes
The HB961 supports various relay output modes for J1 and J2, allowing flexible control based on counting requirements. Refer to the manual diagrams for detailed behavior of each mode (r1sn for J1: 1, 2, 3; r2sn for J2: 1-11).
Video: Instructions on how to set the HB961 indicator to count in inches.
Video: Guide on how to set the HB961 indicator with an incremental string encoder.
Maintenance
To ensure the longevity and accurate performance of your CALT HB961 Pulse Indicator Readout, follow these general maintenance guidelines:
- Cleaning: Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid abrasive cleaners or solvents.
- Environmental Conditions: Operate the device within the specified environmental conditions (0℃ to +50℃; < 85%RH humidity) to prevent damage.
- Connection Integrity: Periodically check all wiring connections to ensure they are secure and free from corrosion or damage.
- Power Supply: Ensure a stable power supply within the specified voltage range to prevent electrical damage.
Troubleshooting
If you encounter issues with your HB961 indicator, consider the following basic troubleshooting steps:
- No Display/Power: Verify the power supply connections and ensure the voltage is within the AC 85-260V / DC 85-360V range. Check for blown fuses if applicable.
- Incorrect Counting: Check sensor wiring for correct polarity and secure connections. Ensure the sensor type (NPN/PNP) is compatible or configured correctly. Verify parameter settings for ratio A, ratio B, and initial value C.
- Relay Malfunction: Confirm relay output mode settings (r1sn, r2sn) and alarm parameter values. Check the relay contact capacity and ensure the load does not exceed specifications.
- Interference Issues: If experiencing erratic readings, ensure proper shielding for sensor cables and consider adding capacitance as noted in the wiring section for inductive loads.
- Parameter Setting Issues: Ensure the correct passwords are used when attempting to access and modify parameters.
For persistent issues, contact CALT customer support or a qualified technician.
Support Information
For further assistance, technical support, or warranty inquiries regarding your CALT HB961 Pulse Indicator Readout, please refer to the contact information provided with your purchase or visit the official CALT website. Ensure you have your product model number (HB961) and any relevant purchase details available when seeking support.