1. Introduction
This manual provides essential information for the safe and effective use of your NMD KS-30 Black Inline Rotary Household On/Off Lamp Switch. Please read these instructions carefully before installation and operation. Retain this manual for future reference.
1.1 Safety Information
- Always disconnect power to the circuit at the main breaker or fuse box before installing, servicing, or removing the switch. Failure to do so may result in serious injury or death.
- This switch is designed for use with 5.5mm thick double wire. Ensure your wiring is compatible.
- Installation should be performed by a qualified electrician or a person with appropriate electrical knowledge.
- Do not exceed the specified electrical ratings of the switch.
- Keep the switch away from water and moisture.
2. Product Overview
The NMD KS-30 is an inline rotary switch designed to provide convenient on/off control for household lamps and other low-power electrical devices. Its compact design allows for integration directly into the power cord.

Figure 2.1: The NMD KS-30 inline rotary lamp switch. This image shows the compact black housing of the switch with its rotary knob visible on the side and screw terminals on the top for wire connection.
2.1 Features
- Operation Mode: ON-OFF
- Actuator Type: Rotary
- Connector Type: Wire Leads
- Terminal: Screw
- Compatibility: Designed for 5.5mm thick double wire.
3. Setup (Installation)
Follow these steps to properly install the NMD KS-30 inline rotary switch into your lamp cord.
3.1 Tools Required
- Small flat-head screwdriver
- Wire strippers
- Utility knife (optional, for splitting wire)
3.2 Installation Steps
- Disconnect Power: Ensure the lamp or appliance is unplugged from the wall outlet.
- Prepare the Cord: Determine the desired location for the switch on the lamp cord. Carefully cut one of the two wires within the cord at this location. Do not cut both wires.
- Open the Switch Housing: Use a small screwdriver to carefully pry open the two halves of the switch housing.
- Strip Wires: Strip approximately 6-8mm (1/4 inch) of insulation from the cut ends of the wire.
- Connect Wires: Insert the stripped wire ends into the screw terminals inside the switch. Ensure that each cut end connects to a separate terminal. Tighten the screws securely to hold the wires in place. The other uncut wire should pass through the channel provided in the switch housing without being cut or stripped.
- Verify Wire Compatibility: The switch is designed for 5.5mm thick double wire. Refer to the image below for visual confirmation of wire size.

Figure 3.1: A digital caliper measuring a double wire, indicating a thickness of 5.5mm. This illustrates the compatible wire size for the NMD KS-30 switch.
- Close the Housing: Carefully align the two halves of the switch housing, ensuring all wires are properly seated in their channels and not pinched. Snap or screw the housing halves together securely.
- Test: Plug the lamp or appliance back into the wall outlet and test the switch operation.
4. Operating
The NMD KS-30 switch features a simple rotary mechanism for operation.
- To turn the connected device ON, rotate the knob clockwise until you feel a click and the device powers on.
- To turn the connected device OFF, rotate the knob counter-clockwise until you feel a click and the device powers off.
5. Maintenance
The NMD KS-30 switch requires minimal maintenance.
- Cleaning: Periodically wipe the exterior of the switch with a dry, soft cloth to remove dust. Do not use liquid cleaners or immerse the switch in water.
- Inspection: Regularly inspect the switch and the connected cord for any signs of damage, fraying, or loose connections. If any damage is observed, discontinue use and replace the switch.
6. Troubleshooting
If you encounter issues with your NMD KS-30 switch, refer to the following common troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn ON/OFF | No power to the circuit Loose wire connection Faulty bulb/device | Check main power supply/breaker. Unplug device, open switch, re-secure wire connections. Test device with another power source or replace bulb. |
| Switch feels loose or damaged | Physical damage Improper installation | Discontinue use immediately. Replace the switch. Ensure housing is securely closed. |
If the problem persists after attempting these solutions, contact customer support.
7. Specifications
Technical details for the NMD KS-30 Inline Rotary Lamp Switch:
- Model: KS-30
- Brand: NMD
- Operation Mode: ON-OFF
- Contact Type: Normally Open
- Connector Type: Wire Leads
- Terminal: Screw
- Circuit Type: 2-way
- Actuator Type: Rotary
- International Protection Rating: IP30
- Number of Positions: 1
- Compatible Wire Thickness: 5.5mm (double wire)
- ASIN: B0829C9WWH
- Date First Available: December 3, 2019
8. Warranty and Support
For warranty information or technical support regarding your NMD KS-30 Inline Rotary Lamp Switch, please refer to the product packaging or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.