Getmorv GE918
User Manual: 100PCS 125KHz RFID Key Fob
Model: GE918 | Brand: Getmorv
Introduction
This manual provides essential information for the proper use and integration of the Getmorv 100PCS 125KHz RFID Key Fobs. These key fobs are designed for use with compatible 125KHz RFID proximity access control and ID management systems.
Important Compatibility Information
- These key fobs operate at a frequency of 125KHz. They are not compatible with other frequencies such as 13.56MHz.
- They are read-only and cannot be rewritten or reprogrammed.
- These fobs are not compatible with encrypted systems (e.g., HID, Indala, Cobra, APCiK, Paradox, Kaba, Isonas).
- They are not compatible with Tuya or TTLock smart locks.
- Ensure your existing access control system uses unencrypted 125KHz technology before attempting to add these key fobs.
Product Overview
The Getmorv 125KHz RFID Key Fobs are contactless proximity ID cards designed for various access control applications. Each fob is pre-programmed with a unique 10-digit ID number, which is engraved on its casing.

Image: A bulk quantity of black 125KHz RFID key fobs, each with a metal keyring, indicating a package of 100 units.

Image: A close-up view of two individual black 125KHz RFID key fobs. One fob displays its front side with a visible engraved 10-digit ID number (e.g., 0004011630), while the other shows its plain reverse side, highlighting the compact design and integrated keyring hole.
These fobs are constructed from durable ABS plastic and are black in color. Their compact size makes them convenient for daily use.
Setup
To integrate these RFID key fobs into your access control system, follow the instructions provided with your specific RFID reader or access control panel.
- Verify Compatibility: Confirm that your access control system operates on an unencrypted 125KHz frequency. These fobs are compatible with universal 125KHz tags like EM4100/4102.
- Identify Unique ID: Each key fob has a unique 10-digit ID number engraved on its casing. This number is crucial for adding the fob to your system.
- Add to System: Refer to your access control system's manual for the procedure to add new ID cards or key fobs. Typically, this involves entering the engraved ID number into the system's database or scanning the fob with a programming device connected to the system.
- Test Functionality: After adding, test each key fob by presenting it to the RFID reader to ensure it grants access as intended.
Note: These fobs are read-only. You cannot use a card writer to change their pre-programmed ID.
Operating Instructions
Using the 125KHz RFID Key Fob is straightforward once it has been successfully added to a compatible access control system.
- Present Fob: Hold the key fob within close proximity (typically 1-5 cm) of the RFID reader on your access control system.
- System Response: The reader will detect the fob's unique ID. If the ID is recognized and authorized by the system, access will be granted (e.g., a door will unlock, a gate will open).
- Visual/Audible Feedback: Most systems provide visual (e.g., LED indicator) or audible (e.g., beep) feedback to confirm successful reading and access.
Maintenance
The Getmorv RFID Key Fobs require minimal maintenance to ensure long-term functionality.
- Cleaning: Wipe the fobs with a soft, dry cloth if they become dirty. Avoid using harsh chemicals or abrasive cleaners.
- Storage: Store fobs in a cool, dry place away from extreme temperatures and strong magnetic fields, which could potentially interfere with their internal components.
- Physical Damage: While durable, avoid subjecting the fobs to excessive force, bending, or dropping, as this could damage the internal RFID chip.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Key fob does not grant access. |
|
|
| Engraved ID number does not work. | System requires a different format or internal ID. | Some systems may require scanning the fob to obtain the correct internal ID, rather than using the engraved number directly. Consult your system's manual. |
| Key fob falls apart. | Manufacturing defect or excessive physical stress. | Discontinue use of the damaged fob. Use another fob from the package. |
Specifications
| Model Number | GE918 |
| Frequency | 125KHz |
| Type | Read Only |
| Compatibility | Universal 125KHz tags (e.g., EM4100/4102) |
| Material | ABS Plastic |
| Color | Black |
| Fob Size (Approx.) | 1.58 x 1.26 x 0.18 inches |
| Unique ID | Pre-programmed 10-digit number (engraved) |
| Quantity | 100 PCS |
Warranty and Support
For warranty information or technical support, please refer to the seller's policies or contact Getmorv customer service directly. Contact details are typically available on the product packaging or the seller's official website.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.