1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Mirage Inverter X Mini Split Air Conditioner. Please read this manual thoroughly before using the unit and retain it for future reference. This unit is designed to provide both cooling and heating functions for residential or commercial spaces.

Image 1.1: The indoor unit of the Mirage Inverter X Mini Split Air Conditioner. This unit is responsible for circulating conditioned air within the room.
2. Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury. This unit operates on 110V electricity and contains refrigerant R-32. Only qualified personnel should perform installation, maintenance, and repairs.
- Do not attempt to install or service the unit yourself. Refer to qualified service personnel.
- Ensure the power supply is disconnected before any cleaning or maintenance.
- Do not insert objects into the air outlet or inlet.
- Keep children and pets away from the unit during operation.
- Do not use flammable sprays near the unit.
- If the unit emits smoke or unusual odors, immediately turn off the power and contact service.
3. Setup and Installation
3.1 Professional Installation
Installation of the Mirage Inverter X Mini Split system requires specialized tools and knowledge. It is mandatory to have the unit installed by a certified HVAC technician to ensure proper function, safety, and warranty validity. Incorrect installation can lead to refrigerant leaks, electrical hazards, and inefficient operation.
3.2 Unit Placement
- Indoor Unit: Mount the indoor unit on a wall where airflow is unobstructed and away from direct sunlight or heat sources. Ensure sufficient space around the unit for maintenance.
- Outdoor Unit: Place the outdoor unit on a stable, level surface, ensuring adequate clearance for air circulation. Avoid locations exposed to strong winds or excessive dust. The outdoor unit is required for operation.
3.3 Electrical Connection
The unit operates on a 110 Volt electrical supply. All electrical wiring must comply with local codes and regulations. A dedicated circuit is recommended. The electrical connection should only be performed by a licensed electrician.
4. Operating Instructions
Your Mirage Inverter X Mini Split comes with a remote control for convenient operation. Ensure the remote control batteries are installed correctly.
4.1 Basic Functions
- Power On/Off: Press the ON/OFF button to start or stop the unit.
- Mode Selection: Press the MODE button to cycle through available modes:
- Cool (Frio): For cooling the room.
- Heat (Calor): For heating the room.
- Fan: Circulates air without cooling or heating.
- Dry: Reduces humidity.
- Auto: Automatically selects mode based on room temperature.
- Temperature Adjustment: Use the TEMP UP/DOWN buttons to set your desired temperature.
- Fan Speed: Press the FAN button to adjust fan speed (Auto, Low, Medium, High).
4.2 Special Features
- Inverter Technology: The Inverter X system adjusts compressor speed to maintain a consistent temperature, leading to energy savings and quieter operation.
- Wi-Fi Compatibility: The unit is Wi-Fi compatible. An optional Wi-Fi module (sold separately) is required to enable control via a smartphone application.
- Soft Start: The compressor starts gradually to reduce initial power surge.
- Memory Key: Stores preferred settings for quick recall.
- Gold Fin: Corrosion-resistant coating on the condenser for extended lifespan.

Image 4.1: Diagram illustrating key features of the Mirage Inverter X, including Soft Start, Wi-Fi compatibility, Luxury Finish, Gold Fin, and Memory Key.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always disconnect power before performing any maintenance.
5.1 Air Filter Cleaning
- Clean the air filters every two weeks, or more frequently if the unit is used heavily or in dusty environments.
- Open the front panel of the indoor unit and remove the filters.
- Wash filters with lukewarm water and a mild detergent. Rinse thoroughly and allow them to dry completely before reinserting.
- Do not operate the unit without filters.
5.2 Outdoor Unit Care
- Keep the area around the outdoor unit clear of debris, leaves, and other obstructions to ensure proper airflow.
- Periodically clean the outdoor coil with a soft brush or vacuum cleaner.
- Do not spray water directly onto the electrical components.
5.3 Seasonal Checks
- Before the cooling or heating season, inspect the unit for any visible damage or unusual conditions.
- Ensure all connections are secure.
- Consider a professional inspection annually.
6. Troubleshooting
Before contacting service, review the following common issues and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not start | No power; remote control batteries dead; timer function active. | Check power supply; replace remote batteries; cancel timer. |
| Insufficient cooling/heating | Dirty air filters; blocked outdoor unit; windows/doors open; incorrect mode/temperature setting. | Clean filters; clear obstructions; close openings; adjust settings. |
| Water leakage from indoor unit | Clogged drain pipe; improper installation (slope); high humidity. | Clean drain pipe; ensure proper drainage slope; if problem persists, contact service. |
| Unusual noise | Loose parts; foreign objects; normal operating sounds (e.g., refrigerant flow). | Check for loose parts; remove foreign objects; if noise is excessive, contact service. |
If the problem persists after attempting these solutions, turn off the unit and contact a qualified service technician.
7. Specifications
| Feature | Detail |
|---|---|
| Brand | Mirage Paris |
| Model Name | Mirage Inverter X |
| Cooling Capacity | 12,000 BTU (1 Ton) |
| Voltage | 110 Volts |
| Refrigerant | R-32 |
| Operating Modes | Cooling, Heating, Fan, Dry, Auto |
| Inverter Type | Yes |
| Indoor Unit Dimensions (DxWxH) | 19.4 cm x 80.5 cm x 28.5 cm |
| Power Source | Corded Electric |
| Compressor Type | Rotary Scroll |
| Application | Residential or Commercial |
| Control Method | Remote Control, Touch (on unit) |
| UPC | 853244008659 |
8. Warranty and Support
8.1 Limited Warranty
The Mirage Inverter X Mini Split Air Conditioner comes with a limited warranty. Please refer to the warranty card included with your product for specific terms, conditions, and duration of coverage. Keep your purchase receipt as proof of purchase for warranty claims.
8.2 Customer Support
For technical assistance, service requests, or inquiries regarding your product, please contact Mirage Paris customer support. Contact information can typically be found on the manufacturer's website or in the product packaging. Ensure you have your model number and purchase details ready when contacting support.