1. Introduction

Thank you for choosing the Dyna-Glo BFSS30LPT-2P 30,000 BTU Liquid Propane Blue Flame Thermostatic Vent Free Wall Heater. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your heater. Please read this manual thoroughly before installation or use and retain it for future reference. This heater is designed for safe, indoor supplemental heating and utilizes vent-free technology, meaning it does not require a flue or chimney.

Dyna-Glo BFSS30LPT-2P Blue Flame Thermostatic Vent Free Wall Heater, front view with blue flames visible through the grate.

Image 1: Front view of the Dyna-Glo BFSS30LPT-2P heater with blue flames.

2. Important Safety Information

Your safety and the safety of others are very important. Please read and understand all safety instructions before installing or operating this heater. Failure to follow these instructions could result in fire, explosion, property damage, personal injury, or death.

  • This heater is for use with Liquid Propane (LP) gas only. Do not attempt to use natural gas or any other fuel.
  • Ensure adequate ventilation when operating this heater.
  • The heater is equipped with an Oxygen Depletion Sensor (ODS) which will automatically shut off the heater if oxygen levels become too low. Do not tamper with or bypass this safety device.
  • Keep combustible materials, gasoline, and other flammable vapors and liquids away from the heater.
  • Do not install this heater in a bathroom or bedroom.
  • Check local regulations regarding installation restrictions and requirements for vent-free heaters. This product is not for sale in California or Canada.
  • Proposition 65 Warning: This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

For a complete list of safety warnings and detailed instructions, please refer to the official User Guide PDF available at: Dyna-Glo BFSS30LPT-2P User Guide (PDF).

3. Package Contents

Upon unpacking, ensure all components are present and undamaged. If any parts are missing or damaged, do not attempt to install or operate the heater. Contact customer service immediately.

  • Dyna-Glo BFSS30LPT-2P Wall Heater Unit
  • Mounting Hardware
  • Wall Mounting Bracket
  • Instruction Manual

Optional Accessories (Sold Separately):

  • WBL100 Base Legs (for floor mounting)
  • WHF100 Wall Heater Fan (for heat distribution)

4. Setup & Installation

This heater is designed for wall mounting. Ensure the installation location complies with all local codes and regulations, and provides adequate clearances from combustible materials. No electricity is required for the basic operation of the heater, making it suitable for emergency heating during power outages.

4.1 Wall Mounting

  1. Select a suitable wall location, ensuring it is structurally sound and provides required clearances.
  2. Attach the wall mounting bracket securely to the wall using the provided hardware.
  3. Carefully lift the heater and hang it onto the wall mounting bracket. Ensure it is seated firmly and level.
Dyna-Glo BFSS30LPT-2P heater mounted on a garage wall, demonstrating typical installation.

Image 2: Heater installed on a garage wall.

Dyna-Glo BFSS30LPT-2P heater mounted on a living room wall, showing aesthetic integration.

Image 3: Heater installed on a living room wall.

4.2 Propane Gas Connection

This heater operates on Liquid Propane (LP) only. A 100-lb. tank or larger with a two-stage adjustable regulator is required and available from your local gas company. Fuel conversion is not permitted.

  1. Locate the propane gas inlet on the heater.
  2. Connect the gas supply line from your propane tank and regulator to the heater's inlet. Ensure all connections are tight and leak-free. Use a gas leak detection solution to check for leaks.
  3. Open the propane tank valve slowly and check for any gas odors.
Close-up view of the propane gas inlet connection point on the heater.

Image 4: Detail of the propane gas inlet.

5. Operating Instructions

The Dyna-Glo BFSS30LPT-2P features thermostatic control and a battery-assisted igniter for convenient operation.

5.1 Ignition

  1. Ensure the propane supply is open.
  2. Press and turn the control knob to the 'PILOT' position.
  3. While holding the knob in, press the battery-assisted igniter button repeatedly until the pilot flame ignites. Continue to hold the control knob for approximately 30-60 seconds after ignition to allow the thermocouple to heat up.
  4. Release the control knob. If the pilot flame extinguishes, repeat the ignition process.
Close-up of the control knob and igniter button on the heater.

Image 5: Control knob and igniter.

5.2 Setting the Temperature

Once the pilot is lit, turn the control knob to your desired heat setting. The thermostatic control will automatically adjust the heat output to maintain the set temperature. The heater offers adjustable heat output from 24,000 to 30,000 BTUs/hr, capable of heating up to 1,000 sq. ft.

5.3 Shutting Down the Heater

To turn off the heater, turn the control knob to the 'OFF' position. For extended periods of non-use, it is recommended to close the valve on the propane tank.

6. Maintenance

Regular maintenance ensures the safe and efficient operation of your heater. Always turn off the heater and disconnect the gas supply before performing any maintenance.

  • Cleaning: Keep the heater's exterior clean by wiping it with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Air Openings: Ensure all air openings are kept clear of dust, lint, and other obstructions.
  • Pilot and Burner: Periodically inspect the pilot and main burner for any blockages or debris. Consult the full user guide for detailed cleaning instructions for these components.
  • Gas Connections: Annually check all gas connections for leaks using a soap and water solution.
Close-up of the thermocouple, a safety device that detects the pilot flame.

Image 6: Detail of the thermocouple.

Close-up of the top vent of the heater, showing the design for heat convection.

Image 7: Detail of the top vent.

7. Troubleshooting

If you encounter issues with your heater, refer to the following common troubleshooting steps. For more detailed solutions, consult the comprehensive user guide.

ProblemPossible CauseSolution
Pilot will not light or stay lit.No gas supply, air in gas line, dirty pilot orifice, faulty thermocouple, low oxygen.Ensure propane tank valve is open. Bleed air from gas line. Clean pilot orifice. Check thermocouple connection. Ensure adequate ventilation.
Main burner does not ignite.Pilot not lit, control knob not set correctly, low gas pressure.Ensure pilot is lit. Turn control knob to a heat setting. Check propane tank level and regulator.
Heater shuts off unexpectedly.Oxygen Depletion Sensor (ODS) activated, low gas pressure, pilot flame extinguished.Increase ventilation. Check propane tank level. Relight pilot.

If problems persist after attempting these solutions, contact a qualified service technician or Dyna-Glo customer support.

8. Specifications

The following are the technical specifications for the Dyna-Glo BFSS30LPT-2P Liquid Propane Blue Flame Thermostatic Vent Free Wall Heater:

FeatureSpecification
BrandDyna-Glo
Model NumberBFSS30LPT-2P
Fuel TypeLiquid Propane (LP)
BTU Output24,000 - 30,000 BTU/hr (Adjustable)
Heating CoverageUp to 1,000 sq. ft.
Ignition TypeBattery-assisted Piezo Ignition
Control TypeThermostatic Control Knob
Safety FeaturesOxygen Depletion Sensor (ODS)
Installation TypeWall-Mounted (Optional floor stand available)
ColorWhite
Product Dimensions (D x W x H)10.51" x 28.07" x 24.09"
Item WeightApproximately 0.01 ounces (Note: This weight seems incorrect, refer to product packaging for actual weight)
UPC872076037811
Diagram showing the dimensions of the Dyna-Glo BFSS30LPT-2P heater: 28.07 inches wide, 24.09 inches high, and 10.51 inches deep.

Image 8: Product dimensions.

9. Warranty & Support

For detailed warranty information, please refer to the warranty card included with your product or visit the official Dyna-Glo website. Keep your proof of purchase for warranty claims.

For technical support, replacement parts, or further assistance, please contact Dyna-Glo customer service. Contact information can typically be found in the full user guide or on the manufacturer's website.

You can also refer to the comprehensive User Guide (PDF) for more information: Dyna-Glo BFSS30LPT-2P User Guide (PDF).