Hill-Rom P1900

Total Care Spo2rt P1900 ICU Bed User Manual

Model: P1900

Brand: Hill-Rom

Introduction

This manual provides comprehensive instructions for the safe and effective use, setup, operation, and maintenance of the Hill-Rom Total Care Spo2rt P1900 ICU Bed. This advanced medical bed is designed to provide comfort and support for patients, featuring an adjustable bed frame, an integrated air mattress, and an optional scale.

Hill-Rom Total Care Spo2rt P1900 ICU Bed with air mattress and scale, shown in an elevated position with the head section raised.

Figure 1: Hill-Rom Total Care Spo2rt P1900 ICU Bed. This image displays the bed with its head and knee sections elevated, showcasing the adjustable frame and the purple air mattress. Side rails are visible, indicating safety features.

Safety Information

It is crucial to read and understand all safety warnings and instructions before operating the Total Care Spo2rt P1900 ICU Bed. Failure to do so may result in injury or damage to the equipment.

Important Safeguards

  • Always use the side rails and locking mechanism when the bed is in use to prevent patient falls.
  • Do not attempt to assemble or disassemble the bed without following the provided instructions. Professional assistance is recommended for initial setup.
  • To maintain safety and prevent damage, wipe the bed with a damp cloth and mild soap only. Avoid harsh chemicals.
  • Ensure all electrical connections are secure and the power cord is not damaged before plugging in the unit.
  • Keep hands and clothing clear of moving parts during bed adjustments.

Setup Instructions

Proper setup ensures the bed operates safely and efficiently.

Unpacking and Placement

  1. Carefully remove all packaging materials. Inspect the bed for any signs of shipping damage. Report any damage immediately to your supplier.
  2. Position the bed on a flat, stable surface in the desired location. Ensure there is adequate space around the bed for operation and maintenance.
  3. Lock all casters to prevent unintended movement during setup and patient transfer.

Air Mattress Installation

  1. Unroll the air mattress onto the bed frame, ensuring it is centered and aligned with the frame.
  2. Connect the air mattress hose to the designated port on the bed's control unit.
  3. Plug the bed's power cord into a grounded electrical outlet.
  4. Turn on the bed's power switch. The air mattress will begin to inflate automatically. Allow sufficient time for full inflation before use.

Operating Instructions

The Total Care Spo2rt P1900 ICU Bed offers various functions for patient comfort and care.

Bed Frame Adjustments

The bed frame can be adjusted using the integrated control panel, typically located on the side rails or footboard.

  • Head Section Adjustment: Use the "Head Up" and "Head Down" buttons to raise or lower the patient's head.
  • Foot Section Adjustment: Use the "Foot Up" and "Foot Down" buttons to raise or lower the patient's feet.
  • Bed Height Adjustment: Use the "Bed Up" and "Bed Down" buttons to adjust the overall height of the bed.
  • Trendelenburg/Reverse Trendelenburg: Specific buttons may be available for these positions, allowing the entire bed to tilt. Consult the control panel for specific icons.

Air Mattress Operation

The integrated air mattress provides pressure redistribution and comfort.

  • Firmness Control: Adjust the mattress firmness using the controls on the bed's panel. Refer to the display for current pressure settings.
  • Therapy Modes: If equipped, select specific therapy modes (e.g., pulsation, alternation) for enhanced pressure relief.

Integrated Scale Function

The bed includes an integrated scale for patient weight monitoring.

  1. Ensure the bed is in a flat, level position and all side rails are up before weighing.
  2. Press the "Weigh" or "Scale" button on the control panel.
  3. Follow on-screen prompts to zero the scale if necessary (e.g., after placing blankets).
  4. The patient's weight will be displayed on the screen.

Maintenance and Care

Regular maintenance ensures the longevity and proper functioning of your ICU bed.

Cleaning Instructions

The bed is designed for easy cleaning.

  • Disconnect the bed from the power supply before cleaning.
  • Wipe all surfaces with a damp cloth and mild, non-abrasive soap.
  • For disinfection, use hospital-grade disinfectants compatible with plastic and metal surfaces. Always follow the disinfectant manufacturer's instructions.
  • Do not immerse any part of the bed in water.
  • Allow all surfaces to dry completely before reconnecting power.

Routine Checks

  • Periodically inspect the power cord for fraying or damage.
  • Check all casters for smooth rotation and ensure brakes engage properly.
  • Verify that side rails latch securely.
  • Listen for unusual noises during bed adjustments, which may indicate a need for professional service.

Troubleshooting Guide

This section provides solutions to common issues you might encounter. For problems not listed here, contact customer support.

ProblemPossible CauseSolution
Bed not responding to controlsPower cord unplugged; circuit breaker tripped; control panel locked.Check power connection; reset circuit breaker; unlock control panel (refer to operating instructions).
Air mattress not inflatingHose disconnected; air pump malfunction.Ensure air hose is securely connected; contact service if pump is not operating.
Side rails not lockingObstruction; latch mechanism damaged.Clear any obstructions; contact service for repair.
Bed making unusual noisesWorn components; lubrication needed.Contact qualified service personnel for inspection and repair.

Product Specifications

Key technical details for the Total Care Spo2rt P1900 ICU Bed.

  • Model: P1900
  • Brand: Hill-Rom
  • ASIN: B07VX5RT25
  • Color: Purple (for mattress/cover)
  • Material: Plastic, Metal
  • Product Care Instructions: Wipe with Damp Cloth
  • First Available: July 29, 2019
  • Key Features: Adjustable Bed Frame, Air Mattress, Safety Features (Side Rails, Locking Mechanism), Easy to Clean, Compact Size.

Warranty and Customer Support

For warranty information, please refer to the documentation provided at the time of purchase or contact Hill-Rom directly.

For technical support, service requests, or parts inquiries, please contact Hill-Rom customer service.

  • Manufacturer: Hill-Rom
  • Website: www.hill-rom.com
  • Contact Information: Refer to manufacturer's website or purchase documentation for current contact details.

© 2024 Hill-Rom. All rights reserved.

This manual is subject to change without notice.