DEWIN AT1-2200X

DEWIN AT1-2200X Variable Frequency Drive User Manual

Model: AT1-2200X

1. Introduction

This manual provides essential information for the safe and efficient operation of your DEWIN AT1-2200X Variable Frequency Drive (VFD). This VFD is designed to convert single-phase 220V AC input into three-phase output, suitable for controlling 2.2kW three-phase asynchronous motors. Please read this manual thoroughly before installation and operation to ensure proper usage and to prevent damage or injury.

DEWIN AT1-2200X Variable Frequency Drive, front view with control panel and safety warning label.

Figure 1: Front view of the DEWIN AT1-2200X VFD, showing the control panel and safety label.

Key Features:

  • Multiple Protection Functions: Includes protection against overcurrent, overvoltage, undervoltage, module failure, overheating, short circuit, input/output phase loss, and more.
  • Excellent Performance: Achieves high torque, high precision, and a wide range of driving speeds with quick start/stop response and high torque at low speeds.
  • Stable Operation: Features good anti-trip performance and adaptability to power supply fluctuations, temperature, humidity, and dust. Equipped with a large heatsink for efficient heat dissipation.
  • Anti-interference Capability: Optimized PWM control technology and electromagnetic compatibility reduce noise and electromagnetic interference.
  • Simple Wiring: Connections are made via screw terminals for straightforward installation.

2. Safety Precautions

WARNING: Failure to follow these safety instructions may result in electric shock, fire, serious injury, or property damage.

  • Always read this manual carefully before operating the VFD.
  • Ensure the power supply is disconnected before performing any wiring or maintenance.
  • Only qualified personnel should perform wiring and installation to avoid electric shock or fire.
  • Do not install the inverter in environments with flammable materials.
  • The ground terminal of the inverter must be reliably grounded.
  • Avoid touching the inverter terminals immediately after disconnecting power, as residual voltage may be present.
Control panel of the DEWIN AT1-2200X VFD with a visible safety precautions label.

Figure 2: Safety precautions label on the VFD unit.

3. Setup and Wiring

Proper wiring is crucial for the safe and correct operation of the VFD. Refer to the wiring diagram below for connections.

Installation wiring diagram for the DEWIN AT1-2200X VFD, showing connections for ground, 220V input, and three-phase asynchronous motor, along with control terminals.

Figure 3: Installation Wiring Diagram.

Terminal Connections:

TerminalFunctionDetails
15V/24VPower Input/Output15V/24V power input, 200mA/15V/24V power supply output.
X6Input Terminal 6Wire control CW/CCW. Connects to COM for effective input signal.
X5Input Terminal 5Wire control CCW. Connects to COM for effective input signal.
X4Input Terminal 4Wire control CW. Connects to COM for effective input signal.
X3Input Terminal 3Speed range 3. Connects to COM for effective input signal.
X2Input Terminal 2Speed range 2. Connects to COM for effective input signal.
X1Input Terminal 1Speed range 1. Connects to COM for effective input signal.
COMCommon TerminalCommon terminal for control signals.
VI1External Analog Voltage Input0-5V/10V analog voltage input.
SP1Open Collector Output 1
SP2Open Collector Output 2
5V/10VPower Supply Output5V/10V 20mA power supply output.

Ensure all connections are secure and correctly matched to your motor and power supply specifications. The VFD requires a single-phase 220V input and provides a three-phase output for the motor.

Back view of the DEWIN AT1-2200X VFD showing power input/output terminals.

Figure 4: Rear view showing power terminals (L, N, W, V, U).

4. Operating Instructions

The DEWIN AT1-2200X VFD features an intuitive control panel for easy operation. Familiarize yourself with the buttons and display functions.

Close-up of the DEWIN AT1-2200X VFD control panel, showing the 5-digit LED display, movement, program, function/data, minus, plus, CW/CCW, stop/reset, and run keys.

Figure 5: Control Panel Buttons.

Control Panel Functions:

  • 5-Digit LED Display: Shows current operating parameters and settings.
  • DISP (Movement Key): Used to switch between monitoring parameters in the monitoring state or to move the data frame to edit bits in the second-level menu.
  • PROG (Programme Key): Exits the current operating state and switches to other states, primarily used to enter the monitoring state.
  • FUNC/DATA (Function/Save Key): Enters the menu step-by-step and saves the configured parameters.
  • ▼ (Minus Key): A short or long press decreases data values or function codes.
  • ▲ (Plus Key): A short or long press increases data values or function codes.
  • FWD/REV (CW/CCW Key): Press to run the motor in the forward direction (CW). Release to stop. Can also be configured for counter-clockwise (CCW) operation.
  • STOP/RESET (Stop/Reset Key): Stops the VFD operation and can be used to recover from a previous error interface.
  • RUN (Operation Key): Initiates the VFD operation.

5. Specifications

Below are the technical specifications for the DEWIN AT1-2200X Variable Frequency Drive:

ParameterValue
BrandDEWIN
Model NumberAT1-2200X
Input VoltageSingle-phase 220V AC
Output VoltageThree-phase 220V AC
Rated Power2.2 kW
Dimensions (L x W x H)18 cm x 31.8 cm x 12.5 cm
Weight1283 Grams
Power SourceCable Electric
GTIN / UPC723645761883
Two DEWIN AT1-2200X VFD units displayed side by side, illustrating the compact design.

Figure 6: DEWIN AT1-2200X VFD units showing dimensions.

6. Maintenance

Regular maintenance helps ensure the longevity and reliable performance of your VFD.

  • Cleaning: Periodically clean the exterior of the VFD with a soft, dry cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow for cooling.
  • Connection Checks: Regularly inspect all wiring connections for tightness and signs of wear or corrosion. Loose connections can lead to overheating or intermittent operation.
  • Environmental Conditions: Ensure the VFD is operated within its specified environmental conditions (temperature, humidity, dust levels) to prevent premature failure.
  • Professional Inspection: For complex issues or internal inspections, it is recommended to consult a qualified technician.
Internal view of the DEWIN AT1-2200X VFD, highlighting the large aluminum heatsink and two cooling fans for heat dissipation.

Figure 7: Internal view showing heatsink and cooling fans.

7. Troubleshooting

If you encounter issues with your VFD, refer to the following basic troubleshooting steps:

  • No Power: Check the main power supply and all input wiring connections. Ensure the circuit breaker or fuse is not tripped.
  • Motor Not Running: Verify that the RUN command is active and that the motor is correctly wired to the VFD output terminals. Check for any error codes on the LED display.
  • Overcurrent/Overload: Reduce the motor load or check for mechanical issues with the motor. Verify that the VFD's current limits are set appropriately for your motor.
  • Overheating: Ensure adequate ventilation around the VFD. Clean any dust from the heatsink and fans. Check ambient temperature.
  • Display Errors: If an error code appears, consult the full product manual (if available) for specific code meanings and resolutions. Try pressing the STOP/RESET key to clear temporary errors.

For persistent issues or complex problems, contact customer support or a qualified electrician.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation included with your purchase or contact your retailer. Keep your purchase receipt as proof of purchase for warranty claims.