FEITA FT-001A
FEITA FT-001A Ionizing Air Blower User Manual
Model: FT-001A
1. Introduction
The FEITA FT-001A Ionizing Air Blower is designed to neutralize static charges and eliminate dust from targeted work surfaces. This device provides protection against the destructive effects of Electrostatic Discharge (ESD) in various industrial and scientific applications. It generates a balanced stream of positive and negative ions to rapidly neutralize static electricity.

Figure 1: FEITA FT-001A Ionizing Air Blower in operation, showing emitted ions.
Key Features:
- Effective static charge decay rates (1-3 seconds).
- Adjustable air flow (45CFM-110CFM).
- Compact, quiet, and lightweight design for versatile placement.
- Suitable for electronics assembly, biological products, LED manufacturing, pharmaceuticals, injection molding, and printing industries.
2. Safety Information
Please read all safety instructions before operating the device to prevent injury or damage. Keep this manual for future reference.
- Power Supply: Ensure the device is connected to an AC110V power source. Do not use with incompatible voltage.
- High Voltage: The internal components operate at high voltage. Do not open the casing or attempt repairs unless qualified. Refer all servicing to qualified personnel.
- Placement: Place the blower on a stable, level surface or mount securely. Ensure adequate ventilation around the unit.
- Moisture: Do not expose the device to water or excessive moisture.
- Cleaning: Disconnect power before cleaning. Use a dry cloth for external cleaning. Follow specific instructions for ion needle cleaning.
- Children and Pets: Keep out of reach of children and pets.

Figure 2: Rear view of the blower, highlighting the power input and high voltage warning label.
3. Product Overview and Components
Familiarize yourself with the various parts of your FEITA FT-001A Ionizing Air Blower.

Figure 3: Front view with labeled components.
- Point Cleaner Knob: Used for cleaning the ion needles.
- Lock Knob: Secures the blower's angle adjustment.
- Ion Release Indicator: Light that indicates ion generation.
- Fan Speed Knob: Controls the air flow intensity (stepless speed regulation).
- Dual Purpose Bracket: Allows for tabletop placement or mounting.
- Installation Screw Hole: For secure mounting.
- Pure Copper Ion Needle: Generates positive and negative ions.
- Cleaning Brush: Tool for maintaining ion needles.

Figure 4: Detail of the pure copper ion needle and cleaning brush.
4. Setup and Installation
Follow these steps to set up your ionizing air blower.
- Unpacking: Carefully remove the blower from its packaging and inspect for any damage.
- Placement:
- For tabletop use, place the blower on a stable, flat surface.
- For mounting, use the installation screw holes on the dual-purpose bracket to secure the unit to a wall or fixture. Ensure it is firmly attached.
- Adjust Angle: Loosen the lock knobs on both sides of the unit to adjust the angle of the blower to direct the airflow as needed. Tighten the lock knobs to secure the desired angle.
- Power Connection: Connect the US standard power cord to the power input on the back of the unit, then plug it into a standard AC110V outlet.

Figure 5: Adjusting the blower angle using the lock knobs.
5. Operating Instructions
Operating the FEITA FT-001A is straightforward.
- Power On: Rotate the Fan Speed Knob clockwise from the "OFF" position to "ON". The ion release indicator light will illuminate, indicating that the unit is generating ions.
- Adjust Airflow: Continue rotating the Fan Speed Knob clockwise to increase the airflow intensity from low to high (HI). Adjust to the desired level for your application.
- Static Elimination: Position the blower so that the ionized air stream covers the work area where static elimination is required. The effective range for static neutralization is approximately 40cm x 60cm, with an optimal installation distance of 30-45cm.
- Power Off: To turn off the unit, rotate the Fan Speed Knob counter-clockwise until it clicks into the "OFF" position. The ion release indicator light will turn off.

Figure 6: The fan speed knob for power and airflow control.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your ionizing air blower.
Ion Needle Cleaning:
The pure copper ion needles should be cleaned regularly to maintain effective ion generation. Frequency of cleaning depends on the operating environment, but generally, it is recommended to clean them weekly or bi-weekly.
- Disconnect Power: Always unplug the unit from the power outlet before performing any maintenance.
- Rotate Point Cleaner Knob: Locate the point cleaner knob at the center of the outlet grille. Simply rotate this knob clockwise until it reaches its stop (approximately one full turn).
- Release: Release the knob. This action uses the internal cleaning brush to wipe away any accumulated debris from the ion needles.
- Repeat: Repeat this process a few times if necessary.

Figure 7: The point cleaner knob for maintaining ion needle cleanliness.
General Cleaning:
- Wipe the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Ensure the fan grille is free from dust and obstructions.
7. Troubleshooting
If you encounter issues with your FEITA FT-001A, refer to the table below for common problems and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not power on. | No power supply; loose power cord; faulty outlet. | Check power cord connection; try a different outlet; ensure power switch is ON. |
| No ionized air/Static not eliminated effectively. | Dirty ion needles; fan speed too low; unit too far from target. | Clean ion needles (refer to Maintenance section); increase fan speed; reposition unit closer to the work surface (30-45cm). |
| Unusual noise during operation. | Obstruction in fan; loose components. | Disconnect power and inspect fan for obstructions. If noise persists, contact customer support. |
8. Specifications
Technical specifications for the FEITA FT-001A Ionizing Air Blower.
- Model: FT-001A
- Input Voltage: AC110V
- Wattage: 27 watts
- Discharge Time: 1-3 seconds (neutral and rapid)
- Air Flow Characteristics: 40cm x 60cm (effective area)
- Optimal Installation Distance: 30-45cm
- Air Velocity: 45CFM-110CFM (adjustable)
- Noise Level: 52 Decibels
- Product Dimensions: 4.08"D x 7.48"W x 9.68"H (10.36cm D x 18.99cm W x 24.59cm H)
- Weight: 4.4 Pounds (2 kg)
- Color: White
- Manufacturer: FEITA INTERNATIONAL LIMITED

Figure 8: Product dimensions diagram.
9. Applications and Performance
The FEITA FT-001A Ionizing Air Blower is suitable for a wide range of applications requiring static control.

Figure 9: Examples of applications and static neutralization performance data.

Figure 10: Various industrial scenes where the ionizing air blower can be applied.
Typical Use Cases:
- Electronics assembly and repair
- Precision electronic production
- Semiconductor manufacturing
- Medical device manufacturing
- Optical instrument assembly
- Printing and packaging industries
- Preventing dust attraction and component sticking
Performance Data (Example):
| Test Conditions | Test Distance | |||
|---|---|---|---|---|
| Test Voltage: 1KV-100V | Ambient Temperature: 71.6°F | 300mm | 600mm | 900mm |
| Neutral Time | Positive | 1.2s | 2.5s | 3.9s |
| Negative | 1.3s | 2.6s | 4.1s | |
| Residual Voltage | Positive | 8V | 5V | 4V |
| Negative | -7V | -6V | -3V | |
10. Warranty and Support
For warranty information or technical support, please refer to the product packaging or contact FEITA customer service directly. Keep your purchase receipt as proof of purchase.
Manufacturer: FEITA INTERNATIONAL LIMITED