1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Foset REGEL-4A Electric Shower Head. Please read these instructions thoroughly before installation and use, and retain them for future reference. The Foset REGEL-4A is designed to provide instant hot water with four adjustable temperature levels, ensuring a comfortable showering experience.

2. Safety Information

WARNING: Risk of Electric Shock. Installation must be performed by a qualified electrician in accordance with all local electrical codes and regulations. Failure to follow these instructions can result in electric shock, fire, or property damage.

3. Package Contents

Verify that all components are present and undamaged before proceeding with installation.

Foset REGEL-4A Electric Shower Head components including the shower head, arm, hose, sprayer, and support.

Figure 1: Components of the Foset REGEL-4A Electric Shower Head. This image displays the main electric shower head unit, the shower arm, a 1.50 meter PVC hose, a separate sprayer, and a wall-mounted support for the sprayer.

4. Specifications

FeatureSpecification
Model NumberREGEL-4A (45155)
BrandFoset
ManufacturerTruper
ColorBlue
Material (Body)Polypropylene Plastic
Material (Handle)Metal and/or Plastic
Temperature Levels4 (Tibia, Caliente, Muy Caliente)
Hose Length1.5 Meters
Dimensions (L x W x H)14.5 x 14.5 x 12.7 cm
Weight400 g
Power Requirement127 V, minimum 50 A circuit breaker
Foset REGEL-4A Electric Shower Head showing a diameter of 14.5 cm.

Figure 2: Dimensions of the Foset REGEL-4A Electric Shower Head, indicating a diameter of 14.5 cm.

5. Installation

5.1 Pre-installation Requirements

5.2 Physical Installation

  1. Turn off the main water supply to the installation area.
  2. Mount the shower arm securely to the wall, ensuring it is level and properly sealed to prevent leaks.
  3. Attach the Foset REGEL-4A Electric Shower Head to the shower arm. Hand-tighten first, then use a wrench if necessary, being careful not to overtighten.
  4. Connect the 1.5-meter PVC hose to the shower head and the sprayer. Mount the sprayer support to a convenient location on the wall.
  5. Turn on the main water supply and check for any leaks. Address any leaks before proceeding.

5.3 Electrical Connection

IMPORTANT: Ensure power is OFF at the main circuit breaker before making any electrical connections.

Diagram illustrating the electrical installation of the Foset REGEL-4A electric shower head, showing connections to a circuit breaker, wire gauges, and water tank height requirements.

Figure 3: Electrical Installation Diagram. This diagram shows the required independent electrical connection, wire color coding (Blue: Line, White: Neutral, Green: Ground), recommended wire gauges based on distance, and the necessary water tank height for proper operation.

  1. Identify the electrical wires from the shower head: Blue (Line), White (Neutral), and Green (Ground).
  2. Connect these wires to the corresponding wires of your dedicated electrical circuit. Ensure secure connections using appropriate electrical connectors.
  3. Verify that the ground wire (Green) is properly connected to the electrical system's ground.
  4. Once all connections are secure and insulated, close the electrical junction box.
  5. Double-check all connections before restoring power.

6. Operation

  1. After installation and before turning on the electrical power, allow water to flow through the shower head for at least 30 seconds to ensure the heating element is fully submerged. This prevents damage to the heating element.
  2. Restore power to the shower head at the circuit breaker.
  3. The Foset REGEL-4A features a selector for four temperature levels:
    • Off: No heating.
    • Tibia: Warm water.
    • Caliente: Hot water.
    • Muy Caliente: Very hot water.
  4. Rotate the selector on the shower head to your desired temperature setting.
  5. Adjust the water flow from your faucet to fine-tune the temperature. Lower flow generally results in hotter water, while higher flow results in cooler water for a given setting.

7. Maintenance

8. Troubleshooting

ProblemPossible CauseSolution
No hot water
  • No electrical power
  • Circuit breaker tripped
  • Insufficient water flow
  • Heating element failure
  • Check power supply to the shower head.
  • Reset the circuit breaker.
  • Ensure adequate water flow before turning on power.
  • Contact a qualified technician for inspection and repair.
Water is not hot enough
  • Temperature selector set too low
  • Excessive water flow
  • Low incoming water temperature
  • Adjust the temperature selector to a higher setting.
  • Reduce water flow from the faucet.
  • This is normal in colder climates; select a higher temperature setting.
Weak water flow
  • Clogged nozzles
  • Low water pressure
  • Clean the shower nozzles.
  • Check the main water supply and ensure the water tank height meets requirements (1-10 meters).

9. Warranty and Support

Foset products are manufactured under strict quality control standards. For warranty information, please refer to the warranty card included with your product or visit the official Foset website. For technical support, replacement parts, or service inquiries, please contact Foset customer service through their official channels.

Manufacturer: Truper

Brand: Foset