1. Introduction
This manual provides essential instructions for the safe and effective operation of your OdorFree Autel 1000 Ozone Machine. This device is designed for professional odor removal in unoccupied spaces by generating ozone (O3) to neutralize odor-causing molecules.
2. Important Safety Information
WARNING: Use Only in Unoccupied Spaces.
Ozone is a powerful oxidizer. Exposure to high concentrations of ozone can be harmful to humans and animals. Adhere strictly to the following safety guidelines:
- The American Lung Association, EPA, and FDA recommend that ozone only be used in unoccupied spaces.
- Ensure no people, pets, or plants are present in the area during ozone treatment.
- Wait at least two hours after the ozone machine has turned off before reoccupying the treated space. Open windows and doors to ventilate the area if possible.
- Individuals with respiratory issues such as COPD, asthma, or emphysema should consult with their physician before any ozone treatment is performed in their environment.
- Do not operate the unit in wet or damp conditions.
- Always unplug the unit before cleaning or maintenance.

Image: Official safety guidelines from the EPA, FDA, and American Lung Association, emphasizing that ozone should only be used in unoccupied spaces and detailing precautions.
3. Product Features
The OdorFree Autel 1000 is engineered for efficient and reliable odor elimination. Key features include:
- Variable Ozone Output: Adjustable from 150-900 mg/hr to suit different odor intensities and room sizes.
- Integrated Timer: A 0 to 60-minute timer for precise treatment durations, with a "Hold" function for extended operation.
- Durable Construction: Heavy-duty metal casing ensures longevity.
- Easy Maintenance: Removable ceramic plates for simple cleaning and replacement.
- Wide Coverage: Effectively treats areas up to 1,000 square feet.
- Low Energy Consumption: Operates efficiently at 30 watts.

Image: The OdorFree Autel 1000 Ozone Machine, showcasing its compact design and control panel.

Image: Detail of the control panel, illustrating the adjustable ozone output and timer settings.

Image: The back of the unit, demonstrating the removable ceramic plates for maintenance and the integrated cord holder.
4. Setup
The OdorFree Autel 1000 is designed for immediate use with no assembly required. Follow these steps to prepare the unit for operation:
- Unpack: Remove the ozone machine from its packaging.
- Placement: Place the unit in the center of the area to be treated, ensuring it is on a stable, flat surface. For optimal air circulation, avoid placing it directly against walls or furniture.
- Power Connection: Plug the power cord into a standard electrical outlet.

Image: The unit is ready to use out of the box, requiring no tools for setup.
5. Operating Instructions
Follow these steps for effective odor treatment:
- Prepare the Area: Ensure the space is completely unoccupied by people, pets, and plants. Remove any valuable artwork or delicate items if concerned about prolonged exposure.
- Place the Unit: Position the OdorFree Autel 1000 in the center of the room or vehicle to be treated.
- Select Ozone Output: Turn the "Ozone Output" knob to the desired level (Low, Medium, or High) based on the severity of the odor. Higher settings are for stronger odors.
- Set Treatment Time: Turn the "Timer" knob to the desired treatment duration (0-60 minutes). For treatments longer than 60 minutes, select the "HOLD" setting.
- Initiate Treatment: Once the timer is set, the unit will begin generating ozone. Immediately vacate the area.
- Post-Treatment Ventilation: After the set time, the unit will turn off. Wait at least two hours before re-entering the treated space. Open windows and doors to ventilate thoroughly.

Image: Visual guide to the four easy steps for operating the OdorFree Autel 1000.

Image: Example of the OdorFree Autel 1000 in use for treating odors inside a vehicle.
Suggested Treatment Times for Autel 1000
Treatment times vary based on the size of the area and the severity of the odor. The table below provides general guidelines. Repeat treatment if necessary.

Image: A table outlining recommended treatment durations for various spaces and odor levels.
| Area | Mild Odor | Medium Odor | Strong Odor |
|---|---|---|---|
| Auto | ½ Hour | 1 Hour | 2 – 8 Hours |
| Hotel Room | ½ Hour | 1 Hour | 2 – 4 Hours |
| Square Feet | |||
| 500 | 1 Hour | 2 Hours | 4 – 6 Hours |
| 1000 | 2 Hours | 4 Hours | 6 – 8 Hours |
| 1500 | 4 Hours | 6 Hours | 8 – 12 Hours |
| Use "HOLD" setting for longer than 60 minutes. Repeat if necessary. | |||
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your OdorFree Autel 1000.
Cleaning Ceramic Ozone Plates
The ceramic ozone plates should be cleaned periodically, especially if you notice a decrease in ozone output or a change in the unit's efficiency. The frequency depends on usage and air quality.
- Disconnect Power: Always unplug the unit from the power outlet before performing any maintenance.
- Access Plates: Locate the plate access panel, typically at the rear of the unit. Carefully slide out the ceramic plates.
- Clean Plates: Use a soft brush or a damp cloth to gently wipe away any dust or residue from the ceramic plates. For stubborn buildup, a mild detergent solution can be used, ensuring the plates are completely dry before reinstallation.
- Reinstall Plates: Carefully slide the clean, dry ceramic plates back into their slots.
- Close Panel: Secure the plate access panel.
Replacement plates are available from OdorFree if the original plates become damaged or worn.
7. Troubleshooting
If your OdorFree Autel 1000 is not functioning as expected, consult the following common issues and solutions:
- Unit Not Turning On:
- Ensure the power cord is securely plugged into a working electrical outlet.
- Check if the timer knob is set correctly (not on "OFF").
- Verify the power outlet is functional by plugging in another device.
- Low Ozone Output:
- Check the "Ozone Output" knob setting; ensure it is not on "LOW".
- Clean the ceramic ozone plates as described in the Maintenance section. Dirty plates can reduce ozone production.
- Ensure the unit's air intake and exhaust vents are not obstructed.
- Odor Persists After Treatment:
- Increase the treatment time or ozone output level.
- Ensure the space was completely sealed during treatment (windows and doors closed).
- Consider repeating the treatment. For very strong, embedded odors, multiple treatments may be necessary.
- Ensure the source of the odor has been removed or cleaned prior to ozone treatment.
If issues persist after attempting these solutions, please contact OdorFree customer support.
8. Specifications
| Feature | Detail |
|---|---|
| Brand | OdorFree |
| Model Number | Autel 1000 |
| Ozone Output | 150-900 mg/hr (Adjustable) |
| Coverage Area | Up to 1000 Square Feet |
| Timer | 0-60 Minute with "HOLD" function |
| Wattage | 30 watts |
| Product Dimensions | 12"D x 9"W x 8"H |
| Item Weight | 10.33 pounds |
| Color | Blue |
| Controller Type | Button Control (Knobs) |
| Special Feature | Re-Usable Plates and Filters Included |
| UPC | 853137004003 |
9. Warranty and Support
Warranty Information
The OdorFree Autel 1000 comes with a comprehensive warranty:
- 5-Year Limited Warranty: For 5 years from the date of purchase by the original owner, OdorFree will replace any defective part due to a manufacturing defect at no charge.
- 90-Day Full Coverage: For the first 90 days from the original date of purchase, OdorFree will replace or repair the product without charge to the customer should the unit prove to have a manufacturing defect or shipping damage.
Customer Support
For technical assistance, troubleshooting, or warranty claims, please contact OdorFree customer support. Support is available 9 AM - 9 PM EST, 7 days a week.
Visit the OdorFree Store for more information and contact details.