1. Introduction
Thank you for choosing the Symphony MOVICOOL L 125 Portable Air Cooler. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your new air cooler. Please read it thoroughly before use and retain it for future reference.

Image 1.1: Front view of the Symphony MOVICOOL L 125 Portable Air Cooler, showcasing its grey design and front grille.
2. Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons.
- Ensure the power supply voltage matches the cooler's rating.
- Do not operate the cooler with a damaged cord or plug.
- Keep the cooler away from water sources and do not immerse it in water.
- Unplug the cooler before filling water, cleaning, or performing maintenance.
- Do not block air inlets or outlets.
- Supervise children and individuals with reduced physical, sensory, or mental capabilities when near the appliance.
- For optimal cooling and cross-ventilation, ensure a door or window is open when the cooler is in operation.
3. Package Contents
Verify that all items are present in the package:
- 1 x Symphony MOVICOOL L 125 Air Cooler Unit
- 4 x Castor Wheels
- 1 x User Manual (this document)
4. Setup
Follow these steps for initial setup:
- Unpacking: Carefully remove the air cooler and all accessories from the packaging.
- Attach Castor Wheels: Turn the cooler upside down or tilt it carefully. Insert the four castor wheels into the designated slots at the bottom of the unit until they click securely into place. Ensure all wheels are firmly attached for stability and mobility.
- Positioning: Place the air cooler on a flat, stable surface. For best performance, position the cooler near an open window or door to allow for proper cross-ventilation.
- Power Connection: Ensure the cooler is switched off before plugging it into a suitable electrical outlet.

Image 4.1: Dimensions of the Symphony MOVICOOL L 125 Air Cooler, showing approximate measurements of 87D x 44W x 140H Centimeters.
5. Operating Instructions
Operating your Symphony MOVICOOL L 125 is straightforward:
- Filling the Water Tank: Open the water inlet and fill the 125-liter water tank with clean water. Monitor the water level indicator to avoid overfilling. For enhanced cooling, you may add ice to the ice chamber if available.
- Power On: Plug the cooler into a power outlet. Turn the main power knob to the 'ON' position.
- Adjust Fan Speed: Use the fan speed knob to select your desired fan speed: Low, Medium, or High. The cooler features a powerful 3-speed fan.
- Activate Cooling: Turn the 'Cool' knob to activate the water pump and cool flow dispenser. This will moisten the honeycomb pads, initiating the evaporative cooling process.
- Adjust Louvers: The cooler is equipped with vertical swing louvers. Use the louver control to adjust the direction of the airflow. The louvers are fully closable to prevent dust entry when not in use.
- Power Off: To turn off the cooler, switch the 'Cool' knob to 'OFF' and then the main power knob to 'OFF'. Unplug the unit from the power outlet when not in use for extended periods.
Video 5.1: An official product video demonstrating the Symphony MOVICOOL L 125 Desert Cooler, highlighting its features and operation.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your air cooler.
- Water Tank Cleaning: Drain and clean the water tank regularly to prevent the buildup of algae, mold, and mineral deposits. Use a soft cloth and mild detergent. Rinse thoroughly.
- Honeycomb Pad Cleaning: The honeycomb pads are designed for low maintenance. Periodically check them for dust accumulation. If heavily soiled, gently rinse them with water. Do not use harsh chemicals.
- Exterior Cleaning: Wipe the exterior of the cooler with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Seasonal Storage: Before storing the cooler for an extended period, ensure the water tank is completely drained and dry. Clean all components and store the unit in a dry, dust-free place.
7. Troubleshooting
If you encounter issues with your air cooler, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Cooler not turning on | No power supply; Power switch off | Check power cord connection; Ensure power outlet is functional; Turn power switch to 'ON' |
| No cooling effect | Water tank empty; Pump not working; 'Cool' function off | Fill water tank; Check pump for obstructions; Turn 'Cool' knob to 'ON' |
| Weak airflow | Low fan speed; Blocked air inlets/outlets | Increase fan speed; Clear any obstructions from grilles |
| Unpleasant odor | Stagnant water; Dirty honeycomb pads | Drain and clean water tank; Clean honeycomb pads |
| Excessive noise | Unit not level; Obstruction in fan; Loose parts | Ensure cooler is on a flat surface; Check for and remove any obstructions; Contact service if noise persists |
8. Specifications
Key technical specifications for the Symphony MOVICOOL L 125 Air Cooler:
| Feature | Detail |
|---|---|
| Model Name | Movicool L 125 |
| Brand | Symphony |
| Mounting Type | Freestanding |
| Special Feature | Adjustable Speed |
| Colour | Grey |
| Controls Type | Knob |
| Reservoir Capacity | 125 Liters (as per product title and feature bullets) |
| Coverage Area | Up to 20 square meters (optimal conditions) |
| Power Consumption | 240 Watts |
| Number of Speeds | 3 |
| Product Dimensions | 87D x 44W x 140H Centimeters |
| Item Weight | 24 kg 400 g |
| Included Components | 1 air cooler with accessories |
9. Warranty and Support
Your Symphony MOVICOOL L 125 cooler is protected by a 1-year warranty from the date of purchase. This warranty covers manufacturing defects only.
For warranty claims, technical support, or service inquiries, please contact Symphony customer service. Refer to the contact information provided with your purchase documentation or visit the official Symphony website.